CTChristopher A. Toth

Christopher A. Toth

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Christopher A. Toth has a total of 35 co-authors. Here are the top co-authors by number of shared publications:

  • Jeffrey I. Jones

    Department of Chemistry and Biochemistry, University of Notre Dame, Notre Dame, Indiana

    5 shared publications
  • John R. Barr

    Division of Laboratory Sciences, Centers for Disease Control and Prevention, Atlanta, GA, USA

    3 shared publications
  • Zsuzsanna Kuklenyik

    Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341, USA

    3 shared publications
  • Bryan A Parks

    Division of Laboratory Sciences, Centers for Disease Control and Prevention, Atlanta, GA, USA

    2 shared publications
  • David M Schieltz

    Division of Laboratory Sciences, Centers for Disease Control and Prevention, Atlanta, GA, USA

    2 shared publications
  • James L Pirkle

    Division of Laboratory Sciences, Centers for Disease Control and Prevention, Atlanta, GA, USA

    2 shared publications

Latest Publications

  • Nuts and Bolts of Protein Quantification by Online Trypsin Digestion Coupled LC-MS/MS Analysis

    by Christopher A. Toth, Zsuzsanna Kuklenyik, John R. Barr

    Protein digestion coupled to liquid chromatography and tandem mass spectrometry (LC-MS/MS) detection enables multiplexed quantification of proteins in complex biological matrices. However, the reproducibility of enzymatic digestion of proteins to produce proteotypic target peptides is a major limiting factor of assay precision. Online digestion using immobilized trypsin addresses this problem through precise control of digestion conditions and time. Because online digestion is typically for a short time, the potential for peptide degradation, a major source of measurement bias, is significantly reduced. Online proteolysis requires minimal sample preparation and is easily coupled to LC-MS/MS systems, further reducing potential method variability. We describe herein a method optimized for the multiplexed quantification of several apolipoproteins in human serum using on-column digestion. We highlight key features of the method that enhance assay accuracy and precision. These include the use of value-assigned serum as calibrators and stable isotope-labeled (SIL) peptide analogs as internal standards. We also comment on practical aspects of column switching valve design, instrument maintenance, tandem mass spectrometry data acquisition, and data processing.


  • Open Access

    Core lipid, surface lipid and apolipoprotein composition analysis of lipoprotein particles as a function of particle size in one workflow integrating asymmetric flow field-flow fractionation and liquid chromatography-tandem mass spectrometry

    by Zsuzsanna Kuklenyik, Jeffery I. Jones, Michael S. Gardner, David M. Schieltz, Bryan A. Parks, Christopher A. Toth, Jon C. Rees, Michael L. Andrews, Kayla Carter, Antony K. Lehtikoski, et al.

    Lipoproteins are complex molecular assemblies that are key participants in the intricate cascade of extracellular lipid metabolism with important consequences in the formation of atherosclerotic lesions and the development of cardiovascular disease. Multiplexed mass spectrometry (MS) techniques have substantially improved the ability to characterize the composition of lipoproteins. However, these advanced MS techniques are limited by traditional pre-analytical fractionation techniques that compromise the structural integrity of lipoprotein particles during separation from serum or plasma. In this work, we applied a highly effective and gentle hydrodynamic size based fractionation technique, asymmetric flow field-flow fractionation (AF4), and integrated it into a comprehensive tandem mass spectrometry based workflow that was used for the measurement of apolipoproteins (apos A-I, A-II, A-IV, B, C-I, C-II, C-III and E), free cholesterol (FC), cholesterol esters (CE), triglycerides (TG), and phospholipids (PL) (phosphatidylcholine (PC), sphingomyelin (SM), phosphatidylethanolamine (PE), phosphatidylinositol (PI) and lysophosphatidylcholine (LPC)). Hydrodynamic size in each of 40 size fractions separated by AF4 was measured by dynamic light scattering. Measuring all major lipids and apolipoproteins in each size fraction and in the whole serum, using total of 0.1 ml, allowed the volumetric calculation of lipoprotein particle numbers and expression of composition in molar analyte per particle number ratios. Measurements in 110 serum samples showed substantive differences between size fractions of HDL and LDL. Lipoprotein composition within size fractions was expressed in molar ratios of analytes (A-I/A-II, C-II/C-I, C-II/C-III. E/C-III, FC/PL, SM/PL, PE/PL, and PI/PL), showing differences in sample categories with combinations of normal and high levels of Total-C and/or Total-TG. The agreement with previous studies indirectly validates the AF4-LC-MS/MS approach and demonstrates the potential of this workflow for characterization of lipoprotein composition in clinical studies using small volumes of archived frozen samples.


  • Optimization of the linear quantification range of an online trypsin digestion coupled liquid chromatography–tandem mass spectrometry (LC–MS/MS) platform

    by Zsuzsanna Kuklenyik, Jeffrey I. Jones, Christopher A. Toth, Michael S. Gardner, James L. Pirkle, John R. Barr

    Tandem mass spectrometry (MS/MS)-based proteomic workflows with a bottom-up approach require enzymatic digestion of proteins to peptide analytes, usually by trypsin. Online coupling of trypsin digestion of proteins, using an immobilized enzyme reactor (IMER), with liquid chromatography (LC) and MS/MS is becoming a frequently used approach. However, finding IMER digestion conditions that allow quantitative analysis of multiple proteins with wide range of endogenous concentration requires optimization of multiple interactive parameters: digestion buffer flow rate, injection volume, sample dilution, and surfactant type/concentration. In this report, we present a design of experiment approach for the optimization of an integrated IMER-LC-MS/MS platform. With bovine serum albumin as a model protein, the digestion efficacy and digestion rate were monitored based on LC-MS/MS peak area count versus protein concentration regression. The optimal parameters were determined through multivariate surface response modeling and consideration of diffusion controlled immobilized enzyme kinetics. The results may provide guidance to other users for the development of quantitative IMER-LC-MS/MS methods for other proteins.


  • Open Access

    High throughput quantification of apolipoproteins A‐I and B‐100 by isotope dilution MS targeting fast trypsin releasable peptides without reduction and alkylation

    by Bryan A Parks, David M Schieltz, Michael L Andrews, Michael S Gardner, Jon C Rees, Christopher A Toth, Jeffrey I Jones, Lisa G McWilliams, Zsuzsanna Kuklenyik, James L Pirkle, et al.

    Purpose: Apolipoprotein A‐I (ApoA‐I) and apolipoprotein B‐100 (ApoB‐100) are amphipathic proteins that are strong predictors of cardiovascular disease risk. The traceable calibration of apolipoprotein assays is a persistent challenge, especially for ApoB‐100, which cannot be solubilized in purified form.Experimental design: A simultaneous quantitation method for ApoA‐I and ApoB‐100 was developed using tryptic digestion without predigestion reduction and alkylation, followed by LC separation coupled with isotope dilution MS analysis. The accuracy of the method was assured by selecting structurally exposed signature peptides, optimal choice of detergent, protein:enzyme ratio, and incubation time. Peptide calibrators were value assigned by isobaric tagging isotope dilution MS amino acid analysis.Results: The method reproducibility was validated in technical repeats of three serum samples, giving 2–3% intraday CVs (N = 5) and N = 21). The repeated analysis of interlaboratory harmonization standards showed −1% difference for ApoA‐I and −12% for ApoB‐100 relative to the assigned value. The applicability of the method was demonstrated by repeated analysis of 24 patient samples with a wide range of total cholesterol and triglyceride levels.Conclusions and clinical relevance: The method is applicable for simultaneous analysis of ApoA‐I and ApoB‐100 in patient samples, and for characterization of serum pool calibrators for other analytical platforms.


  • On-column trypsin digestion coupled with LC-MS/MS for quantification of apolipoproteins

    by Christopher A Toth, Zsuzsanna Kuklenyik, Jeffrey I Jones, Bryan A Parks, Michael S Gardner, David M Schieltz, Jon C Rees, Michael L Andrews, Lisa G McWilliams, James L Pirkle, et al.


  • Open Access

    The effects of apolipoprotein B depletion on HDL subspecies composition and function

    by W. Sean Davidson, Anna Heink, Hannah Sexmith, John T. Melchior, Scott M. Gordon, Zsuzsanna Kuklenyik, Laura Woollett, John R. Barr, Jeffrey I. Jones, Christopher A. Toth, et al.


  • Highly Enantioselective Cyclizations of Conjugated Trienes with Low Catalyst Loadings: A Robust Chiral N-Heterocyclic Carbene Enabled by Acetic Acid Cocatalyst

    by Guansai Liu, Phillip D. Wilkerson, Christopher A. Toth, Hao Xu

    Densely functionalized cyclopentenones are useful synthetic intermediates. We report herein a new method to synthesize this important class of compounds through a highly enantioselective (98 → 99% ee) triene cyclization that is cocatalyzed by acetic acid and a chiral N-heterocyclic carbene (NHC). We discovered that acetic acid not only could coexist with NHCs but also could greatly stabilize the active catalyst, which enables a long-lived catalyst with high reactivity and selectivity.