Iterative framework for the joint segmentation and CT synthesis of MR images: application to MRI-only radiotherapy treatment planning
Open Access
- 5 May 2017
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (11) , 4237-4253
Abstract
To tackle the problem of magnetic resonance imaging (MRI)-only radiotherapy treatment planning (RTP), we propose a multi-atlas information propagation scheme that jointly segments organs and generates pseudo x-ray computed tomography (CT) data from structural MR images (T1-weighted and T2-weighted). As the performance of the method strongly depends on the quality of the atlas database composed of multiple sets of aligned MR, CT and segmented images, we also propose a robust way of registering atlas MR and CT images, which combines structure-guided registration, and CT and MR image synthesis. We first evaluated the proposed framework in terms of segmentation and CT synthesis accuracy on 15 subjects with prostate cancer. The segmentations obtained with the proposed method were compared using the Dice score coefficient (DSC) to the manual segmentations. Mean DSCs of 0.73, 0.90, 0.77 and 0.90 were obtained for the prostate, bladder, rectum and femur heads, respectively. The mean absolute error (MAE) and the mean error (ME) were computed between the reference CTs (non-rigidly aligned to the MRs) and the pseudo CTs generated with the proposed method. The MAE was on average [Formula: see text] HU and the ME [Formula: see text] HU. We then performed a dosimetric evaluation by re-calculating plans on the pseudo CTs and comparing them to the plans optimised on the reference CTs. We compared the cumulative dose volume histograms (DVH) obtained for the pseudo CTs to the DVH obtained for the reference CTs in the planning target volume (PTV) located in the prostate, and in the organs at risk at different DVH points. We obtained average differences of [Formula: see text] in the PTV for [Formula: see text], and between [Formula: see text] and 0.05% in the PTV, bladder, rectum and femur heads for D mean and [Formula: see text]. Overall, we demonstrate that the proposed framework is able to automatically generate accurate pseudo CT images and segmentations in the pelvic region, potentially bypassing the need for CT scan for accurate RTP.Keywords
Funding Information
- NIHR Biomedical Research Centre UCLH/UCL High Impact Initiative (BW.mn.BRC10269)
- Engineering and Physical Sciences Research Council (EP/H046410/1, EP/M020533/1, EP/K005278)
- Cancer Research UK (A21993, C33589/A19727, C1060/A16464, C1060/A10334)
This publication has 32 references indexed in Scilit:
- Joint Segmentation and CT Synthesis for MRI-only Radiotherapy Treatment Planning2016
- Learning-Based Multimodal Image Registration for Prostate Cancer Radiation Therapy2016
- Atlas-guided generation of pseudo-CT images for MRI-only and hybrid PET–MRI-guided radiotherapy treatment planningPhysics in Medicine & Biology, 2016
- Robust CT Synthesis for Radiotherapy Planning: Application to the Head and Neck Region2015
- Multi-contrast attenuation map synthesis for PET/MR scanners: assessment on FDG and Florbetapir PET tracersEuropean Journal of Nuclear Medicine and Molecular Imaging, 2015
- Using image synthesis for multi-channel registration of different image modalitiesProceedings of SPIE, 2015
- Attenuation Correction Synthesis for Hybrid PET-MR Scanners: Application to Brain StudiesIEEE Transactions on Medical Imaging, 2014
- A Probabilistic Patch-Based Label Fusion Model for Multi-Atlas Segmentation With Registration Refinement: Application to Cardiac MR ImagesIEEE Transactions on Medical Imaging, 2013
- A review of atlas-based segmentation for magnetic resonance brain imagesComputer Methods and Programs in Biomedicine, 2011
- Iconic feature based nonrigid registration: the PASHA algorithmComputer Vision and Image Understanding, 2003