JMJamie R. McClelland

Jamie R. McClelland

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jamie R. McClelland has a total of 484 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A low-cost, flexible, and accurate technique to study new immobilisation systems for radiotherapy and their 2D in-plane positional reproducibility and stability

    by Chung Tin Lo, Jamie R McClelland, Tracy Underwood

    Recently, there has been a resurgence of interest in upright, gantry-less radiotherapy due to its potential to reduce the costs associated with new treatment rooms and improve comfort/clinical outcomes for specific patient groups. Consequently, new patient positioning and immobilisation devices are being developed for upright and conventional radiotherapy. Before any new RT immobilisation system is implemented clinically, pre-clinical tests should be performed to verify its reproducibility and stability. Surface-guided radiotherapy (SGRT) can be used; however, commercial SGRT systems are expensive and can require complex installation and calibration procedures. Therefore, we developed a low-cost, flexible 2D in-plane displacement measurement system to support the testing and development of new immobilisation devices for RT. The method developed in this work couples ArUco markers with regular cameras positioned orthogonally on tripods to capture images in two planes. Markers fixed onto human subjects can then be used to assess the inter- and intra-fractional repeatability and stability associated with new immobilisation systems. A Python algorithm was developed to automatically detect ArUCo markers in each camera image and infer the distance between markers across multiple camera images. Contrary to most measurement systems, the proposed method does not require camera calibration, and any camera with sufficiently high image resolution and relatively low lens distortion can be used. Rigorous validation experiments, using simulated data, were performed to test the algorithm’s measurement accuracy for different marker separations and camera-to-marker distances. Accuracy validation test results show that the proposed system has a mean measurement error below 1mm. These errors are at the same order of magnitude as the commercial SGRT systems. The proposed system provides a viable low-cost solution for assessing positional repeatability and stability of new immobilisation devices during pre-clinical development. This is particularly relevant as new positioning systems are being developed for both upright and conventional supine RT treatments.

  • Open Access

    Conditional organs-of-interest segmentation with plausible inter-fraction variation simulation for pancreatic magnetic resonance-guided radiotherapy in limited-data settings

    by Mehdi Shojaei, Björn Eiben, Jamie R. McClelland, Simeon Nill, Alex Dunlop, Robert W. Chuter, Arabella Hunt, Brian Ng-Cheng-Hin, Uwe Oelfke

  • Open Access

    Detection of errors in organs at risk delineations for radiotherapy for clinical trial reviews

    by C Dronne, C H Clark, X Loizeau, E Miles, P Hoskin, J R McClelland

    Objective. As part of treatment planning for radiotherapy, the organs at risk (OARs) are delineated on the patient’s CT scan. This work aims to develop a method to measure variability in OAR delineations and detect errors. Approach. A normative modelling approach was implemented by training a variational autoencoder (VAE) on a dataset of images and delineations to model the “acceptable” variability distribution. The trained VAE was then used to reconstruct unseen cases. Disagreements between input and reconstructed delineations highlighted regions where the input deviated from the training distribution. This approach was validated by evaluating the reconstructions of spinal cord and brainstem delineations where common clinical errors had been introduced. Main results. Results showed that the model successfully detected errors, even when only a few voxels or slices were added or removed. Distance to agreement maps were generated to quantify the magnitude of the disagreements in misclassified regions. These results were further validated by manually evaluating some of the test cases. Significance. This tool has the potential of assisting clinicians in reviewing and validating OAR delineations.

  • Open Access

    A robust auto-contouring and data augmentation pipeline for adaptive MRI-guided radiotherapy of pancreatic cancer with a limited dataset

    by Mehdi Shojaei, Björn Eiben, Jamie R McClelland, Simeon Nill, Alex Dunlop, Arabella Hunt, Brian Ng-Cheng-Hin, Uwe Oelfke

    Objective. This study aims to develop and evaluate a fast and robust deep learning-based auto-segmentation approach for organs at risk in MRI-guided radiotherapy of pancreatic cancer to overcome the problems of time-intensive manual contouring in online adaptive workflows. The research focuses on implementing novel data augmentation techniques to address the challenges posed by limited datasets. Approach. This study was conducted in two phases. In phase I, we selected and customized the best-performing segmentation model among ResU-Net, SegResNet, and nnU-Net, using 43 balanced 3DVane images from 10 patients with 5-fold cross-validation. Phase II focused on optimizing the chosen model through two advanced data augmentation approaches to improve performance and generalizability by increasing the effective input dataset: (1) a novel structure-guided deformation-based augmentation approach (sgDefAug) and (2) a generative adversarial network-based method using a cycleGAN (GANAug). These were compared with comprehensive conventional augmentations (ConvAug). The approaches were evaluated using geometric (Dice score, average surface distance (ASD)) and dosimetric (D2% and D50% from dose-volume histograms) criteria. Main results. The nnU-Net framework demonstrated superior performance (mean Dice: 0.78 ± 0.10, mean ASD: 3.92 ± 1.94 mm) compared to other models. The sgDefAug and GANAug approaches significantly improved model performance over ConvAug, with sgDefAug demonstrating slightly superior results (mean Dice: 0.84 ± 0.09, mean ASD: 3.14 ± 1.79 mm). The proposed methodology produced auto-contours in under 30 s, with 75% of organs showing less than 1% difference in D2% and D50% dose criteria compared to ground truth. Significance. The integration of the nnU-Net framework with our proposed novel augmentation technique effectively addresses the challenges of limited datasets and stringent time constraints in online adaptive radiotherapy for pancreatic cancer. Our approach offers a promising solution for streamlining online adaptive workflows and represents a substantial step forward in the practical application of auto-segmentation techniques in clinical radiotherapy settings.


  • Open Access

    Data driven surrogate signal extraction for dynamic PET using selective PCA: time windows versus the combination of components

    by Alexander C Whitehead, Kuan-Hao Su, Elise C Emond, Ander Biguri, Ludovica Brusaferri, Maria Machado, Joanna C Porter, Helen Garthwaite, Scott D Wollenweber, Jamie R McClelland, et al.

    Objective. Respiratory motion correction is beneficial in positron emission tomography (PET), as it can reduce artefacts caused by motion and improve quantitative accuracy. Methods of motion correction are commonly based on a respiratory trace obtained through an external device (like the real time position management system) or a data driven method, such as those based on dimensionality reduction techniques (for instance principal component analysis (PCA)). PCA itself being a linear transformation to the axis of greatest variation. Data driven methods have the advantage of being non-invasive, and can be performed post-acquisition. However, their main downside being that they are adversely affected by the tracer kinetics of the dynamic PET acquisition. Therefore, they are mostly limited to static PET acquisitions. This work seeks to extend on existing PCA-based data-driven motion correction methods, to allow for their applicability to dynamic PET imaging. Approach. The methods explored in this work include; a moving window approach (similar to the Kinetic Respiratory Gating method from Schleyer et al (2014)), extrapolation of the principal component from later time points to earlier time points, and a method to score, select, and combine multiple respiratory components. The resulting respiratory traces were evaluated on 22 data sets from a dynamic [18F]-FDG study on patients with idiopathic pulmonary fibrosis. This was achieved by calculating their correlation with a surrogate signal acquired using a real time position management system. Main results. The results indicate that all methods produce better surrogate signals than when applying conventional PCA to dynamic data (for instance, a higher correlation with a gold standard respiratory trace). Extrapolating a late time point principal component produced more promising results than using a moving window. Scoring, selecting, and combining components held benefits over all other methods. Significance. This work allows for the extraction of a surrogate signal from dynamic PET data earlier in the acquisition and with a greater accuracy than previous work. This potentially allows for numerous other methods (for instance, respiratory motion correction) to be applied to this data (when they otherwise could not be previously used).

  • Open Access

    Modelling systematic anatomical uncertainties of head and neck cancer patients during fractionated radiotherapy treatment

    by Poppy Nikou, Anna Thompson, Andrew Nisbet, Sarah Gulliford, Jamie R McClelland

    Objective. Head and neck cancer patients experience systematic as well as random day to day anatomical changes during fractionated radiotherapy treatment. Modelling the expected systematic anatomical changes could aid in creating treatment plans which are more robust against such changes. Approach. Inter- patient correspondence aligned all patients to a model space. Intra- patient correspondence between each planning CT scan and on treatment cone beam CT scans was obtained using diffeomorphic deformable image registration. The stationary velocity fields were then used to develop B-Spline based patient specific (SM) and population average (AM) models. The models were evaluated geometrically and dosimetrically. A leave-one-out method was used to compare the training and testing accuracy of the models. Main results. Both SMs and AMs were able to capture systematic changes. The average surface distance between the registration propagated contours and the contours generated by the SM was less than 2 mm, showing that the SM are able to capture the anatomical changes which a patient experiences during the course of radiotherapy. The testing accuracy was lower than the training accuracy of the SM, suggesting that the model overfits to the limited data available and therefore, also captures some of the random day to day changes. For most patients the AMs were a better estimate of the anatomical changes than assuming there were no changes, but the AMs could not capture the variability in the anatomical changes seen in all patients. No difference was seen in the training and testing accuracy of the AMs. These observations were highlighted in both the geometric and dosimetric evaluations and comparisons. Significance. In this work, a SM and AM are presented which are able to capture the systematic anatomical changes of some head and neck cancer patients over the course of radiotherapy treatment. The AM is able to capture the overall trend of the population, but there is large patient variability which highlights the need for more complex, capable population models.


  • Open Access

    Respiratory motion modelling for MR-guided lung cancer radiotherapy: model development and geometric accuracy evaluation

    by Björn Eiben, Jenny Bertholet, Elena H Tran, Andreas Wetscherek, Anna-Maria Shiarli, Simeon Nill, Uwe Oelfke, Jamie R McClelland

    Objective. Respiratory motion of lung tumours and adjacent structures is challenging for radiotherapy. Online MR-imaging cannot currently provide real-time volumetric information of the moving patient anatomy, therefore limiting precise dose delivery, delivered dose reconstruction, and downstream adaptation methods. Approach. We tailor a respiratory motion modelling framework towards an MR-Linac workflow to estimate the time-resolved 4D motion from real-time data. We develop a multi-slice acquisition scheme which acquires thick, overlapping 2D motion-slices in different locations and orientations, interleaved with 2D surrogate-slices from a fixed location. The framework fits a motion model directly to the input data without the need for sorting or binning to account for inter- and intra-cycle variation of the breathing motion. The framework alternates between model fitting and motion-compensated super-resolution image reconstruction to recover a high-quality motion-free image and a motion model. The fitted model can then estimate the 4D motion from 2D surrogate-slices. The framework is applied to four simulated anthropomorphic datasets and evaluated against known ground truth anatomy and motion. Clinical applicability is demonstrated by applying our framework to eight datasets acquired on an MR-Linac from four lung cancer patients. Main results. The framework accurately reconstructs high-quality motion-compensated 3D images with 2 mm 3 isotropic voxels. For the simulated case with the largest target motion, the motion model achieved a mean deformation field error of 1.13 mm. For the patient cases residual error registrations estimate the model error to be 1.07 mm (1.64 mm), 0.91 mm (1.32 mm), and 0.88 mm (1.33 mm) in superior-inferior, anterior-posterior, and left-right directions respectively for the building (application) data. Significance. The motion modelling framework estimates the patient motion with high accuracy and accurately reconstructs the anatomy. The image acquisition scheme can be flexibly integrated into an MR-Linac workflow whilst maintaining the capability of online motion-management strategies based on cine imaging such as target tracking and/or gating.


  • Open Access

    Surrogate-driven respiratory motion model for projection-resolved motion estimation and motion compensated cone-beam CT reconstruction from unsorted projection data

    by Yuliang Huang, Kris Thielemans, Gareth Price, Jamie R McClelland

    Objective. As the most common solution to motion artefact for cone-beam CT (CBCT) in radiotherapy, 4DCBCT suffers from long acquisition time and phase sorting error. This issue could be addressed if the motion at each projection could be known, which is a severely ill-posed problem. This study aims to obtain the motion at each time point and motion-free image simultaneously from unsorted projection data of a standard 3DCBCT scan. Approach. Respiration surrogate signals were extracted by the Intensity Analysis method. A general framework was then deployed to fit a surrogate-driven motion model that characterized the relation between the motion and surrogate signals at each time point. Motion model fitting and motion compensated reconstruction were alternatively and iteratively performed. Stochastic subset gradient based method was used to significantly reduce the computation time. The performance of our method was comprehensively evaluated through digital phantom simulation and also validated on clinical scans from six patients. Results. For digital phantom experiments, motion models fitted with ground-truth or extracted surrogate signals both achieved a much lower motion estimation error and higher image quality, compared with non motion-compensated results.For the public SPARE Challenge datasets, more clear lung tissues and less blurry diaphragm could be seen in the motion compensated reconstruction, comparable to the benchmark 4DCBCT images but with a higher temporal resolution. Similar results were observed for two real clinical 3DCBCT scans. Significance. The motion compensated reconstructions and motion models produced by our method will have direct clinical benefit by providing more accurate estimates of the delivered dose and ultimately facilitating more accurate radiotherapy treatments for lung cancer patients.


  • Open Access

    Independent component analysis (ICA) applied to dynamic oxygen‐enhanced MRI (OE‐MRI) for robust functional lung imaging at 3 T

    by Sarah H. Needleman, Mina Kim, Jamie R. McClelland, Josephine H. Naish, Marta Tibiletti, James P. B. O'COnnor, Geoff J. M. Parker

    Purpose: Dynamic lung oxygen‐enhanced MRI (OE‐MRI) is challenging due to the presence of confounding signals and poor signal‐to‐noise ratio, particularly at 3 T. We have created a robust pipeline utilizing independent component analysis (ICA) to automatically extract the oxygen‐induced signal change from confounding factors to improve the accuracy and sensitivity of lung OE‐MRI.Methods: Dynamic OE‐MRI was performed on healthy participants using a dual‐echo multi‐slice spoiled gradient echo sequence at 3 T and cyclical gas delivery. ICA was applied to each echo within a thoracic mask. The ICA component relating to the oxygen‐enhancement signal was automatically identified using correlation analysis. The oxygen‐enhancement component was reconstructed, and the percentage signal enhancement (PSE) was calculated. The lung PSE of current smokers was compared with nonsmokers; scan–rescan repeatability, ICA pipeline repeatability, and reproducibility between two vendors were assessed.Results: ICA successfully extracted a consistent oxygen‐enhancement component for all participants. Lung tissue and oxygenated blood displayed the opposite oxygen‐induced signal enhancements. A significant difference in PSE was observed between the lungs of current smokers and nonsmokers. The scan–rescan repeatability and the ICA pipeline repeatability were good.Conclusion: The developed pipeline demonstrated sensitivity to the signal enhancements of the lung tissue and oxygenated blood at 3 T. The difference in lung PSE between current smokers and nonsmokers indicates a likely sensitivity to lung function alterations that may be seen in mild pathology, supporting future use of our methods in patient studies.


  • Open Access

    Independent component analysis (ICA) applied to dynamic oxygen-enhanced MRI (OE-MRI) for robust functional lung imaging at 3 T

    by Sarah H. Needleman, Mina Kim, Jamie R. McClelland, Josephine H. Naish, Marta Tibiletti, James P. B. O’connor, Geoff J. M. Parker

    Purpose: Dynamic lung oxygen-enhanced MRI (OE-MRI) is challenging due to the presence of confounding signals and poor signal-to-noise ratio, particularly at 3 T. We have created a robust pipeline utilizing independent component analysis (ICA) to automatically extract the oxygen-induced signal change from confounding factors to improve the accuracy and sensitivity of lung OE-MRI. Methods: Dynamic OE-MRI was performed on healthy participants using a dual-echo multi- slice spoiled gradient echo sequence at 3 T and cyclical gas delivery. ICA was applied to each echo within a thoracic mask. The ICA component relating to the oxygen-enhancement signal was automatically identified using correlation analysis. The oxygen-enhancement component was reconstructed, and the percentage signal enhancement (PSE) was calculated. The lung PSE of current smokers was compared with non-smokers; scan-rescan repeatability, ICA pipeline repeatability, and reproducibility between two vendors, were assessed. Results: ICA successfully extracted a consistent oxygen-enhancement component for all participants. Lung tissue and oxygenated blood displayed opposite oxygen-induced signal enhancements. A significant difference in PSE was observed between the lungs of current smokers and non-smokers. The scan-rescan repeatability, and the ICA pipeline repeatability, were good. Conclusion: The developed pipeline demonstrated sensitivity to the signal enhancements of the lung tissue and oxygenated blood at 3 T. The difference in lung PSE between current smokers and non-smokers indicates a likely sensitivity to lung function alterations that may be seen in mild pathology, supporting future use of our methods in patient studies.