Antithrombogenic Properties of a Monopivot Magnetic Suspension Centrifugal Pump for Circulatory Assist
- 16 April 2008
- journal article
- Published by Wiley in Artificial Organs
- Vol. 32 (6) , 484-489
Abstract
Abstract: The National Institute of Advanced Industrial Science and Technology (AIST) monopivot magnetic suspension centrifugal pump (MC105) was developed for open‐heart surgery and several weeks of circulatory assist. The monopivot centrifugal pump has a closed impeller of 50 mm in diameter, supported by a single pivot bearing, and is driven through a magnetic coupling to widen the fluid gap. Design parameters such as pivot length and tongue radius were determined through flow visualization experiments, and the effectiveness was verified in preliminary animal experiments. The maximum overall pump efficiency reached 18%, and the normalized index of hemolysis tested with bovine blood was as low as 0.0013 g/100 L. Animal experiments with MC105 were conducted in sheep for 3, 15, 29, and 35 days in a configuration of left ventricle bypass. No thrombus was formed around the pivot bearing except when the pump speed was reduced by 20% of normal operational speed, which reduced the pump flow by 40% to avoid inlet suction. Subsequently, the antithrombogenic design was verified in animal experiments for 5 weeks at a minimum rotational speed of greater than 1500 rpm and a minimum pump flow greater than 1.0 L/min; no thrombus formation was observed under these conditions.Keywords
This publication has 8 references indexed in Scilit:
- A randomized multicenter clinical study to evaluate the safety and efficacy of the TandemHeart percutaneous ventricular assist device versus conventional therapy with intraaortic balloon pumping for treatment of cardiogenic shockAmerican Heart Journal, 2006
- Computational Fluid Dynamic Analysis of the Flow around the Pivot Bearing of the Centrifugal Ventricular Assist Device (Effects of Design Variations of the Washout Hole, the Pivot and the Back Gap)JSME International Journal Series C, 2006
- The Hemolytic Characteristics of Monopivot Magnetic Suspension Blood Pumps With Washout HolesArtificial Organs, 2005
- The Most Profitable Use of Flow Visualization in the Elimination of Thrombus from a Monopivot Magnetic Suspension Blood PumpArtificial Organs, 2004
- Tsukuba Remote Monitoring System for Continuous‐Flow Artificial HeartArtificial Organs, 2003
- A Clinical Use of the Kyocera Gyro C1E3 Centrifugal PumpArtificial Organs, 2000
- Seal‐less Centrifugal Blood Pump with Magnetically Suspended Rotor: Rot‐a‐FlotArtificial Organs, 1995
- Experimental results and future prospects for a nonpulsatile cardiac prosthesisWorld Journal of Surgery, 1985