Abstract
Objective: To evaluate the image quality, radiation dose, and renal safety of contrast medium (CM)-reduced abdominal–pelvic CT combining 80-kVp and sinogram-affirmed iterative reconstruction (SAFIRE) in patients with renal dysfunction for oncological assessment. Methods: We included 45 patients with renal dysfunction (estimated glomerular filtration rate 60 ml per lmin per 1.73 m2) who underwent standard oncological abdominal–pelvic CT (600 mgI kg–1, 120-kVp, filtered-back projection) were included as controls. CT attenuation, image noise, and contrast-to-noise ratio (CNR) were compared. Two observers performed subjective image analysis on a 4-point scale. Size-specific dose estimate and renal function 1–3 months after CT were measured. Results: The size-specific dose estimate and iodine load of 80-kVp protocol were 32 and 41%,, respectively, lower than of 120-kVp protocol (p < 0.01). CT attenuation and contrast-to-noise ratio of parenchymal organs and vessels in 80-kVp images were significantly better than those of 120-kVp images (p < 0.05). There were no significant differences in quantitative or qualitative image noise or subjective overall quality (p > 0.05). No significant kidney injury associated with CM administration was observed. Conclusion: 80-kVp abdominal–pelvic CT with SAFIRE yields diagnostic image quality in oncology patients with renal dysfunction under substantially reduced iodine and radiation dose without renal safety concerns. Advances in knowledge: Using 80-kVp and SAFIRE allows for 40% iodine load and 32% radiation dose reduction for abdominal–pelvic CT without compromising image quality and renal function in oncology patients at risk of contrast-induced nephropathy.Keywords
This publication has 44 references indexed in Scilit:
- Effect of Radiation Dose Reduction and Reconstruction Algorithm on Image Noise, Contrast, Resolution, and Detectability of Subtle Hypoattenuating Liver Lesions at Multidetector CT: Filtered Back Projection versus a Commercial Model–based Iterative Reconstruction AlgorithmRadiology, 2017
- Risk of Acute Kidney Injury After Intravenous Contrast Media AdministrationAnnals of Emergency Medicine, 2017
- Noise Texture DeviationInvestigative Radiology, 2017
- Coronary Computed Tomographic Angiography at Low Concentration of Contrast Agent and Low Tube Voltage in Patients with Obesity:Academic Radiology, 2016
- Comparing five different iterative reconstruction algorithms for computed tomography in an ROC studyEuropean Radiology, 2014
- Effect of automatic tube voltage selection on image quality and radiation dose in abdominal CT angiography of various body sizes: A phantom studyClinical Radiology, 2013
- Establishment of CT diagnostic reference levels in IrelandBritish Journal of Radiology, 2012
- Low Contrast Agent and Radiation Dose Protocol for Hepatic Dynamic CT of Thin Adults at 256–Detector Row CT: Effect of Low Tube Voltage and Hybrid Iterative Reconstruction Algorithm on Image QualityRadiology, 2012
- Image Noise and Liver Lesion Detection With MDCT: A Phantom StudyAmerican Journal of Roentgenology, 2011
- Revised Equations for Estimated GFR From Serum Creatinine in JapanAmerican Journal of Kidney Diseases, 2009