90Y-labelled glass microspheres liver radioembolisation is an effective treatment for unresectable hepatic tumours. Its treatment planning is based on 99mTc-macro-aggregated albumin (MAA) single photon emission computed tomography (SPECT) imaging. However, photons interaction with human tissues may significantly compromise the accuracy of radioactivity quantification in nuclear medicine. The aim of this work is to evaluate the impact of a patient-specific attenuation correction on pre-treatment 99mTc-MAA SPECT images and, consequently, on the estimation of radioembolisation dosimetry. The methodology developed for attenuation correction was firstly validated on phantom models. Following this, a data set of eight patients was retrospectively selected from our database and the pre-treatment images were reconstructed with and without attenuation correction. Then, the liver dosimetry maps were estimated and compared with the liver dosimetry maps estimated from the post-treatment 90Y positron emission tomography images. Results show that the attenuation corrected phantom images were greatly improved, originating higher contrast, signal-to-noise ratio and contrast-to-noise ratio comparatively to non-attenuation corrected images. Attenuation corrected clinical pre-treatment images significantly increase the agreement, measured with the intraclass correlation coefficient, between predictive and post-treatment dosimetry maps comparatively to the non-attenuation corrected ones (Wilcoxon test, p = 0.008). In conclusion, a statistically significant increase in the agreement was achieved; however, poor correlation is still observed at the single-voxel level in some patients. Thus, future research should be addressed to investigate the reasons of this and manage to optimise the agreement between the predictive and post-treatment dosimetry.Keywords
This publication has 14 references indexed in Scilit:
- Optimization of activity and absorbed doses calculation to target/tumor and normal liver volumes in patients submitted to yttrium-90 radioembolization with glass microspheresPhysica Medica, 2016
- Partition Model–Based 99mTc-MAA SPECT/CT Predictive Dosimetry Compared with 90Y TOF PET/CT Posttreatment Dosimetry in Radioembolization of Hepatocellular Carcinoma: A Quantitative Agreement ComparisonJournal of Nuclear Medicine, 2016
- Clinical impact of 99mTc-MAA SPECT/CT-based dosimetry in the radioembolization of liver malignancies with 90Y-loaded microspheresEuropean Journal of Nuclear Medicine and Molecular Imaging, 2015
- 90Y Radioembolization: Multimodality Imaging Pattern Approach with Angiographic Correlation for Optimized Target Therapy DeliveryRadioGraphics, 2015
- 99mTc-Macroaggregated Albumin Poorly Predicts the Intrahepatic Distribution of 90Y Resin Microspheres in Hepatic RadioembolizationJournal of Nuclear Medicine, 2013
- The Significance of 99mTc-MAA SPECT/CT Liver Perfusion Imaging in Treatment Planning for 90Y-Microsphere Selective Internal Radiation TreatmentJournal of Nuclear Medicine, 2010
- Holmium-166 radioembolization for the treatment of patients with liver metastases: design of the phase I HEPAR trialJournal of Experimental & Clinical Cancer Research, 2010
- Quantitative Comparison of Yttrium-90 (90 Y)-Microspheres and Technetium-99m (99m Tc)-Macroaggregated Albumin SPECT Images for Planning 90 Y Therapy of Liver CancerTechnology in Cancer Research & Treatment, 2010
- SPECT/CT with 99mTc-MAA in Radioembolization with 90Y Microspheres in Patients with Hepatocellular CancerJournal of Nuclear Medicine, 2009
- Investigation of the relationship between linear attenuation coefficients and CT Hounsfield units using radionuclides for SPECTApplied Radiation and Isotopes, 2008