Paulo Ferreira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Paulo Ferreira has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Durval Campos Costaa
Champalimaud Clinical Centre, Champalimaud Foundation , 1400-038 Lisbon
7 shared publications - Francisco P. M. Oliveira
Nuclear Medicine-Radiopharmacology, Champalimaud Clinical Centre/Champalimaud Foundation, Lisbon, Portugal
5 shared publications - Paulo Lobato Correia
Instituto de Telecomunicações, Instituto Superior Técnico, Universidade de Lisboa
5 shared publications - Rui Parafita
Champalimaud Foundation
4 shared publications - Pedro Silva Girao
Instituto de Telecomunicações
3 shared publications - Laura Demino
Center of Physics and Engineering of Advanced Materials, CeFEMA, Instituto Superior Técnico, University of Lisbon, Lisbon, Portugal
2 shared publications
Latest Publications
- Open Access
- 17 November 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (22) , 11669
An Optimized Methodology for Patient-Specific Therapeutic Activity Administration in Liver Radioembolization
Radioembolization (RE) with glass microspheres (MS) loaded with Yttrium-90 (90Y) has been used to treat tumors in the liver with some reported success. However, assessing absorbed doses (AD) in the planning tumor volume (PTV) and normal liver volume (NLV) is a key problem to address in RE. In clinical practice, the computation of 90Y activity to be administered follows the manufacturer’s recommendations, which do not consider the specific characteristics of MS deposition in each patient’s liver. Our main aim is to develop a methodology to estimate the optimal activity for each patient treatment. It uses the absorbed dose distribution (ADD) derived from the Technetium-99m (99mTc)-labeled macroaggregated albumin (MAA) obtained from pre-treatment planning single-photon emission computed tomography (SPECT) images. Post-treatment positron emission tomography (PET) images of the 90Y-MS distribution were used to estimate the ADD for treatment verification. Sixteen RE treatments were retrospectively selected. The agreement between the estimated mean AD based on the planning imaging and real post-treatment mean AD was good in PTV with an intraclass correlation coefficient (ICC) of 0.79 and excellent in NLV (ICC = 0.97). The optimization of 90Y activity using pre-defined clinical AD thresholds (80 Gy in PTV) imposed on the PTV and NLV voxels showed remarkably high agreement (ICC = 0.96, p < 0.001) in eleven out of the sixteen RE treatments between SPECT-MAA-based and PET-MS-based optimal activity estimates. In conclusion, under well-controlled conditions, pre-treatment SPECT-MAA imaging predicts well the treatment of ADD. In addition, SPECT-MAA imaging can be used to optimize the 90Y-MS activity to be administered to the liver.
- 17 November 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (22) , 11669
Open AccessAn Optimized Methodology for Patient-Specific Therapeutic Activity Administration in Liver Radioembolization
Radioembolization (RE) with glass microspheres (MS) loaded with Yttrium-90 (90Y) has been used to treat tumors in the liver with some reported success. However, assessing absorbed doses (AD) in the planning tumor volume (PTV) and normal liver volume (NLV) is a key problem to address in RE. In clinical practice, the computation of 90Y activity to be administered follows the manufacturer’s recommendations, which do not consider the specific characteristics of MS deposition in each patient’s liver. Our main aim is to develop a methodology to estimate the optimal activity for each patient treatment. It uses the absorbed dose distribution (ADD) derived from the Technetium-99m (99mTc)-labeled macroaggregated albumin (MAA) obtained from pre-treatment planning single-photon emission computed tomography (SPECT) images. Post-treatment positron emission tomography (PET) images of the 90Y-MS distribution were used to estimate the ADD for treatment verification. Sixteen RE treatments were retrospectively selected. The agreement between the estimated mean AD based on the planning imaging and real post-treatment mean AD was good in PTV with an intraclass correlation coefficient (ICC) of 0.79 and excellent in NLV (ICC = 0.97). The optimization of 90Y activity using pre-defined clinical AD thresholds (80 Gy in PTV) imposed on the PTV and NLV voxels showed remarkably high agreement (ICC = 0.96, p < 0.001) in eleven out of the sixteen RE treatments between SPECT-MAA-based and PET-MS-based optimal activity estimates. In conclusion, under well-controlled conditions, pre-treatment SPECT-MAA imaging predicts well the treatment of ADD. In addition, SPECT-MAA imaging can be used to optimize the 90Y-MS activity to be administered to the liver.
- 28 September 2019
- Published by Springer Nature
- p. 208-216
Voxel-Based Computational Tools Help Liver Dosimetry Calculations of Multiple (External and Internal) Radiation Therapies
- 28 September 2019
- Published by Springer Nature
- p. 208-216
Voxel-Based Computational Tools Help Liver Dosimetry Calculations of Multiple (External and Internal) Radiation Therapies
- 2 November 2018
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization
- Vol. 7 (5-6) , 651-659
Comparison of the 90Y-labelled glass microspheres liver radioembolisation dosimetry with the estimated dosimetry obtained from pre-treatment 99mTc-MAA SPECT images reconstructed with and without attenuation correction
90Y-labelled glass microspheres liver radioembolisation is an effective treatment for unresectable hepatic tumours. Its treatment planning is based on 99mTc-macro-aggregated albumin (MAA) single photon emission computed tomography (SPECT) imaging. However, photons interaction with human tissues may significantly compromise the accuracy of radioactivity quantification in nuclear medicine. The aim of this work is to evaluate the impact of a patient-specific attenuation correction on pre-treatment 99mTc-MAA SPECT images and, consequently, on the estimation of radioembolisation dosimetry. The methodology developed for attenuation correction was firstly validated on phantom models. Following this, a data set of eight patients was retrospectively selected from our database and the pre-treatment images were reconstructed with and without attenuation correction. Then, the liver dosimetry maps were estimated and compared with the liver dosimetry maps estimated from the post-treatment 90Y positron emission tomography images. Results show that the attenuation corrected phantom images were greatly improved, originating higher contrast, signal-to-noise ratio and contrast-to-noise ratio comparatively to non-attenuation corrected images. Attenuation corrected clinical pre-treatment images significantly increase the agreement, measured with the intraclass correlation coefficient, between predictive and post-treatment dosimetry maps comparatively to the non-attenuation corrected ones (Wilcoxon test, p = 0.008). In conclusion, a statistically significant increase in the agreement was achieved; however, poor correlation is still observed at the single-voxel level in some patients. Thus, future research should be addressed to investigate the reasons of this and manage to optimise the agreement between the predictive and post-treatment dosimetry.
- 2 November 2018
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization
- Vol. 7 (5-6) , 651-659
Comparison of the 90Y-labelled glass microspheres liver radioembolisation dosimetry with the estimated dosimetry obtained from pre-treatment 99mTc-MAA SPECT images reconstructed with and without attenuation correction
90Y-labelled glass microspheres liver radioembolisation is an effective treatment for unresectable hepatic tumours. Its treatment planning is based on 99mTc-macro-aggregated albumin (MAA) single photon emission computed tomography (SPECT) imaging. However, photons interaction with human tissues may significantly compromise the accuracy of radioactivity quantification in nuclear medicine. The aim of this work is to evaluate the impact of a patient-specific attenuation correction on pre-treatment 99mTc-MAA SPECT images and, consequently, on the estimation of radioembolisation dosimetry. The methodology developed for attenuation correction was firstly validated on phantom models. Following this, a data set of eight patients was retrospectively selected from our database and the pre-treatment images were reconstructed with and without attenuation correction. Then, the liver dosimetry maps were estimated and compared with the liver dosimetry maps estimated from the post-treatment 90Y positron emission tomography images. Results show that the attenuation corrected phantom images were greatly improved, originating higher contrast, signal-to-noise ratio and contrast-to-noise ratio comparatively to non-attenuation corrected images. Attenuation corrected clinical pre-treatment images significantly increase the agreement, measured with the intraclass correlation coefficient, between predictive and post-treatment dosimetry maps comparatively to the non-attenuation corrected ones (Wilcoxon test, p = 0.008). In conclusion, a statistically significant increase in the agreement was achieved; however, poor correlation is still observed at the single-voxel level in some patients. Thus, future research should be addressed to investigate the reasons of this and manage to optimise the agreement between the predictive and post-treatment dosimetry.
- 1 August 2018
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization
- Vol. 7 (5-6) , 583-589
Patient-specific gamma-index analysis to evaluate 99mTc-MAA as a predictor for 90Y glass microspheres liver radioembolisation dosimetry
Radioembolisation (RE) is a minimally invasive therapy for primary/metastatic liver tumours. Yttrium-90 (90Y) microspheres (MS) are infused through the hepatic artery. Positron emission tomography (PET) allows visualisation of the 90Y-MS distribution in the liver after the RE procedure. All patients are submitted to a pretherapeutic Technetium-99m (99mTc) macroaggregated albumin (MAA) perfusion scintigraphy and single-photon emission computed tomography (SPECT) liver imaging. This work investigates the value of pre-treatment 99mTc-MAA SPECT to predict intrahepatic 90Y-MS treatment dosimetry, using the gamma-index (γ-index) analytical method. Six treatments with MAA and MS administered in the same hepatic artery branches were retrospectively selected. Multimodal images were used for semi-automatic and manual segmentation of liver and tumour volumes. Absorbed dose was calculated on SPECT and PET maps using the Imalytics Research Workstation (Philips). The γ-index calculation and analysis were performed using ‘in-house’ software with multiple distance to agreement (DTA) and dose difference (DD) tolerance criteria. γ-index passing rate values of 80% and > 90% were achieved for respectively conservative 10 mm/10% and less conservative 15 mm/15% (DTA/DD) tolerance criteria. RE treatments performed in similar conditions to planning give γ-index passing rates (several DTA/DD criteria) indicating potential predictive power of dosimetry planning for post-radioembolisation dosimetry outcome.
- 1 August 2018
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization
- Vol. 7 (5-6) , 583-589
Patient-specific gamma-index analysis to evaluate 99mTc-MAA as a predictor for 90Y glass microspheres liver radioembolisation dosimetry
Radioembolisation (RE) is a minimally invasive therapy for primary/metastatic liver tumours. Yttrium-90 (90Y) microspheres (MS) are infused through the hepatic artery. Positron emission tomography (PET) allows visualisation of the 90Y-MS distribution in the liver after the RE procedure. All patients are submitted to a pretherapeutic Technetium-99m (99mTc) macroaggregated albumin (MAA) perfusion scintigraphy and single-photon emission computed tomography (SPECT) liver imaging. This work investigates the value of pre-treatment 99mTc-MAA SPECT to predict intrahepatic 90Y-MS treatment dosimetry, using the gamma-index (γ-index) analytical method. Six treatments with MAA and MS administered in the same hepatic artery branches were retrospectively selected. Multimodal images were used for semi-automatic and manual segmentation of liver and tumour volumes. Absorbed dose was calculated on SPECT and PET maps using the Imalytics Research Workstation (Philips). The γ-index calculation and analysis were performed using ‘in-house’ software with multiple distance to agreement (DTA) and dose difference (DD) tolerance criteria. γ-index passing rate values of 80% and > 90% were achieved for respectively conservative 10 mm/10% and less conservative 15 mm/15% (DTA/DD) tolerance criteria. RE treatments performed in similar conditions to planning give γ-index passing rates (several DTA/DD criteria) indicating potential predictive power of dosimetry planning for post-radioembolisation dosimetry outcome.
- 13 October 2017
- Published by Springer Nature
- p. 185-191
Radioembolization with 90Y-Labeled Glass Microspheres: Analytical Methods for Patient-Personalized Voxel-Based Dosimetry
- 13 October 2017
- Published by Springer Nature
- p. 185-191
Radioembolization with 90Y-Labeled Glass Microspheres: Analytical Methods for Patient-Personalized Voxel-Based Dosimetry
- 1 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Gamma-index and dose-volume histograms (based on voxel dosimetry) to evaluate the predictive power of 99mTc-MAA SPECT maps in comparison with post-radioembolization 90Y PET maps
Radioembolization (RE) with 90 Y microspheres has been recognized as an emerging treatment strategy for patients with liver tumors either primary or secondary. New tools for complex patient dosimetry, based on real absorbed dose distribution to the normal liver and tumor are under development by our research group at the Champalimaud Centre for the Unknown (CCU), Champalimaud Foundation (CF). Furthermore, we have been using the gamma-index quantitative approach to evaluate the degree of agreement between reference and target voxel-based dose distributions. In this research work, we quantitatively investigated the correlation between dose distributions calculated based on pre-treatment/reference Technetium-99m Macroaggregated Albumin ( 99m Tc-MAA) Single Photon Emission Computed Tomography (SPECT) and post-treatment/target Yttrium-90 ( 90 Y) Positron Emission Tomography (PET) images, to evaluate the predictive power of 99m Tc-MAA SPECT maps in comparison with post-radioembolization 90 Y PET maps. Voxel-based dose distributions were retrospectively calculated based on a total of 13 treatments from 10 patients submitted to RE with 90 Y glass microspheres at CCU-CF. The dose distributions (reference and target) were co-registered to the same matrix resolution and a region extraction algorithm was applied to the entire data for each treatment so that only the liver was considered as the region of interest (ROI). In addition, each slice was normalized to the pixel with the maximum intensity value and a dose threshold was applied to the background level. The gamma-index test was then applied to all reference and target pairs of slices from each treatment image series ( 99m Tc-MAA SPECT and 90 Y PET), using the dose-difference (DD) and distance-to-agreement (DTA) tolerances. The computation based on 1766 dose maps (slices) included in this work, showed that the mean percentage of voxels passing gamma-index, for each patient, varies from 17% to 48%. Considering all the patients, the median of this variability is 35% and the mean value is 33% with a standard deviation of 10% In conclusion, the application of gamma-index tests to our data, with the tolerances considered (DD = 10% and DTA = 5mm), reveals good correlation between pre-treatment 99m Tc-MAA SPECT dose maps and post-treatment 90 Y PET dose maps in one third of the voxels analyzed. Considering that the deposition of the microspheres (glass and MAA) and the dose maps are heterogeneous, these preliminary results are encouraging and led us to further consider the application of this gamma-index quantitative approach together with dose-volume histograms to investigate the additional predictive power of 99m Tc-MAA SPECT maps in comparison with post-therapy 90 Y PET maps.
- 1 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Gamma-index and dose-volume histograms (based on voxel dosimetry) to evaluate the predictive power of 99mTc-MAA SPECT maps in comparison with post-radioembolization 90Y PET maps
Radioembolization (RE) with 90 Y microspheres has been recognized as an emerging treatment strategy for patients with liver tumors either primary or secondary. New tools for complex patient dosimetry, based on real absorbed dose distribution to the normal liver and tumor are under development by our research group at the Champalimaud Centre for the Unknown (CCU), Champalimaud Foundation (CF). Furthermore, we have been using the gamma-index quantitative approach to evaluate the degree of agreement between reference and target voxel-based dose distributions. In this research work, we quantitatively investigated the correlation between dose distributions calculated based on pre-treatment/reference Technetium-99m Macroaggregated Albumin ( 99m Tc-MAA) Single Photon Emission Computed Tomography (SPECT) and post-treatment/target Yttrium-90 ( 90 Y) Positron Emission Tomography (PET) images, to evaluate the predictive power of 99m Tc-MAA SPECT maps in comparison with post-radioembolization 90 Y PET maps. Voxel-based dose distributions were retrospectively calculated based on a total of 13 treatments from 10 patients submitted to RE with 90 Y glass microspheres at CCU-CF. The dose distributions (reference and target) were co-registered to the same matrix resolution and a region extraction algorithm was applied to the entire data for each treatment so that only the liver was considered as the region of interest (ROI). In addition, each slice was normalized to the pixel with the maximum intensity value and a dose threshold was applied to the background level. The gamma-index test was then applied to all reference and target pairs of slices from each treatment image series ( 99m Tc-MAA SPECT and 90 Y PET), using the dose-difference (DD) and distance-to-agreement (DTA) tolerances. The computation based on 1766 dose maps (slices) included in this work, showed that the mean percentage of voxels passing gamma-index, for each patient, varies from 17% to 48%. Considering all the patients, the median of this variability is 35% and the mean value is 33% with a standard deviation of 10% In conclusion, the application of gamma-index tests to our data, with the tolerances considered (DD = 10% and DTA = 5mm), reveals good correlation between pre-treatment 99m Tc-MAA SPECT dose maps and post-treatment 90 Y PET dose maps in one third of the voxels analyzed. Considering that the deposition of the microspheres (glass and MAA) and the dose maps are heterogeneous, these preliminary results are encouraging and led us to further consider the application of this gamma-index quantitative approach together with dose-volume histograms to investigate the additional predictive power of 99m Tc-MAA SPECT maps in comparison with post-therapy 90 Y PET maps.