Robust electromagnetically guided endoscopic procedure using enhanced particle swarm optimization for multimodal information fusion
- 20 March 2015
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 42 (4) , 1808-1817
Abstract
Purpose: Electromagnetically guided endoscopic procedure, which aims at accurately and robustly localizing the endoscope, involves multimodal sensory information during interventions. However, it still remains challenging in how to integrate these information for precise and stable endoscopic guidance. To tackle such a challenge, this paper proposes a new framework on the basis of an enhanced particle swarm optimization method to effectively fuse these information for accurate and continuous endoscope localization.Methods: The authors use the particle swarm optimization method, which is one of stochastic evolutionary computation algorithms, to effectively fuse the multimodal information including preoperative information (i.e., computed tomography images) as a frame of reference, endoscopic camera videos, and positional sensor measurements (i.e., electromagnetic sensor outputs). Since the evolutionary computation method usually limits its possible premature convergence and evolutionary factors, the authors introduce the current (endoscopic camera and electromagnetic sensor's) observation to boost the particle swarm optimization and also adaptively update evolutionary parameters in accordance with spatial constraints and the current observation, resulting in advantageous performance in the enhanced algorithm.Results: The experimental results demonstrate that the authors’ proposed method provides a more accurate and robust endoscopic guidance framework than state‐of‐the‐art methods. The average guidance accuracy of the authors’ framework was about 3.0 mm and 5.6° while the previous methods show at least 3.9 mm and 7.0°. The average position and orientation smoothness of their method was 1.0 mm and 1.6°, which is significantly better than the other methods at least with (2.0 mm and 2.6°). Additionally, the average visual quality of the endoscopic guidance was improved to 0.29.Conclusions: A robust electromagnetically guided endoscopy framework was proposed on the basis of an enhanced particle swarm optimization method with using the current observation information and adaptive evolutionary factors. The authors proposed framework greatly reduced the guidance errors from (4.3, 7.8) to (3.0 mm, 5.6°), compared to state‐of‐the‐art methods.Keywords
This publication has 23 references indexed in Scilit:
- Development and comparison of new hybrid motion tracking for bronchoscopic navigationMedical Image Analysis, 2012
- Electromagnetic Navigation Bronchoscopy in the Diagnosis of Peripheral Lung LesionsClinical Pulmonary Medicine, 2011
- In VivoValidation of a Hybrid Tracking System for Navigation of an Ultrathin Bronchoscope Within Peripheral AirwaysIEEE Transactions on Biomedical Engineering, 2009
- Selective image similarity measure for bronchoscope tracking based on image registrationMedical Image Analysis, 2009
- Computer-based system for the virtual-endoscopic guidance of bronchoscopyComputer Vision and Image Understanding, 2007
- Electromagnetic navigation diagnostic bronchoscopy for small peripheral lung lesionsEuropean Respiratory Journal, 2007
- The Future of Bronchoscopy in Diagnosing, Staging and Treatment of Lung CancerRespiration, 2006
- Bronchoscopic Biopsy of Peripheral Lung Lesions Under Electromagnetic GuidanceJournal of Bronchology, 2005
- A tutorial on particle filters for online nonlinear/non-Gaussian Bayesian trackingIEEE Transactions on Signal Processing, 2002
- Registration of real and CT-derived virtual bronchoscopic images to assist transbronchial biopsyIEEE Transactions on Medical Imaging, 1998