Xiongbiao Luo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xiongbiao Luo has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Terry M. Peters
Robarts Research Institute, Western University, London, Canada
2 shared publications - Uditha L. Jayarathne
Western University
2 shared publications - Ying Wan
School of Computing and Communications, University of Technology, Sydney, Australia
2 shared publications - Elvis C. S. Chen
Department of Medical Biophysics, Robarts Research Institute, Western University, London, ON, Canada
1 shared publication - Kensaku Mori
Graduate School of Informatics, Nagoya University, Nagoya, Japan
1 shared publication - Stephen E. Pautler
Divisions of Urology and Surgical Oncology, Departments of Surgery and Oncology, Western University, London, Canada
1 shared publication
Latest Publications
- 10 December 2015
- Published by Springer Nature
- p. 134-144
Simultaneous Estimation of Feature Correspondence and Stereo Object Pose with Application to Ultrasound Augmented Robotic Laparoscopy
- 10 December 2015
- Published by Springer Nature
- p. 134-144
Simultaneous Estimation of Feature Correspondence and Stereo Object Pose with Application to Ultrasound Augmented Robotic Laparoscopy
- 4 August 2015
- Published by Springer Nature
- p. 664-676
Binocular Endoscopic 3-D Scene Reconstruction Using Color and Gradient-Boosted Aggregation Stereo Matching for Robotic Surgery
- 4 August 2015
- Published by Springer Nature
- p. 664-676
Binocular Endoscopic 3-D Scene Reconstruction Using Color and Gradient-Boosted Aggregation Stereo Matching for Robotic Surgery
- 1 August 2015
- Published by Elsevier in Medical Image Analysis
- Vol. 24 (1) , 282-296
Observation-driven adaptive differential evolution and its application to accurate and smooth bronchoscope three-dimensional motion tracking
- 1 August 2015
- Published by Elsevier in Medical Image Analysis
- Vol. 24 (1) , 282-296
Observation-driven adaptive differential evolution and its application to accurate and smooth bronchoscope three-dimensional motion tracking
- 20 March 2015
- Published by Wiley in Medical Physics
- Vol. 42 (4) , 1808-1817
Robust electromagnetically guided endoscopic procedure using enhanced particle swarm optimization for multimodal information fusion
Purpose: Electromagnetically guided endoscopic procedure, which aims at accurately and robustly localizing the endoscope, involves multimodal sensory information during interventions. However, it still remains challenging in how to integrate these information for precise and stable endoscopic guidance. To tackle such a challenge, this paper proposes a new framework on the basis of an enhanced particle swarm optimization method to effectively fuse these information for accurate and continuous endoscope localization.Methods: The authors use the particle swarm optimization method, which is one of stochastic evolutionary computation algorithms, to effectively fuse the multimodal information including preoperative information (i.e., computed tomography images) as a frame of reference, endoscopic camera videos, and positional sensor measurements (i.e., electromagnetic sensor outputs). Since the evolutionary computation method usually limits its possible premature convergence and evolutionary factors, the authors introduce the current (endoscopic camera and electromagnetic sensor's) observation to boost the particle swarm optimization and also adaptively update evolutionary parameters in accordance with spatial constraints and the current observation, resulting in advantageous performance in the enhanced algorithm.Results: The experimental results demonstrate that the authors’ proposed method provides a more accurate and robust endoscopic guidance framework than state‐of‐the‐art methods. The average guidance accuracy of the authors’ framework was about 3.0 mm and 5.6° while the previous methods show at least 3.9 mm and 7.0°. The average position and orientation smoothness of their method was 1.0 mm and 1.6°, which is significantly better than the other methods at least with (2.0 mm and 2.6°). Additionally, the average visual quality of the endoscopic guidance was improved to 0.29.Conclusions: A robust electromagnetically guided endoscopy framework was proposed on the basis of an enhanced particle swarm optimization method with using the current observation information and adaptive evolutionary factors. The authors proposed framework greatly reduced the guidance errors from (4.3, 7.8) to (3.0 mm, 5.6°), compared to state‐of‐the‐art methods.
- 20 March 2015
- Published by Wiley in Medical Physics
- Vol. 42 (4) , 1808-1817
Robust electromagnetically guided endoscopic procedure using enhanced particle swarm optimization for multimodal information fusion
Purpose: Electromagnetically guided endoscopic procedure, which aims at accurately and robustly localizing the endoscope, involves multimodal sensory information during interventions. However, it still remains challenging in how to integrate these information for precise and stable endoscopic guidance. To tackle such a challenge, this paper proposes a new framework on the basis of an enhanced particle swarm optimization method to effectively fuse these information for accurate and continuous endoscope localization.Methods: The authors use the particle swarm optimization method, which is one of stochastic evolutionary computation algorithms, to effectively fuse the multimodal information including preoperative information (i.e., computed tomography images) as a frame of reference, endoscopic camera videos, and positional sensor measurements (i.e., electromagnetic sensor outputs). Since the evolutionary computation method usually limits its possible premature convergence and evolutionary factors, the authors introduce the current (endoscopic camera and electromagnetic sensor's) observation to boost the particle swarm optimization and also adaptively update evolutionary parameters in accordance with spatial constraints and the current observation, resulting in advantageous performance in the enhanced algorithm.Results: The experimental results demonstrate that the authors’ proposed method provides a more accurate and robust endoscopic guidance framework than state‐of‐the‐art methods. The average guidance accuracy of the authors’ framework was about 3.0 mm and 5.6° while the previous methods show at least 3.9 mm and 7.0°. The average position and orientation smoothness of their method was 1.0 mm and 1.6°, which is significantly better than the other methods at least with (2.0 mm and 2.6°). Additionally, the average visual quality of the endoscopic guidance was improved to 0.29.Conclusions: A robust electromagnetically guided endoscopy framework was proposed on the basis of an enhanced particle swarm optimization method with using the current observation information and adaptive evolutionary factors. The authors proposed framework greatly reduced the guidance errors from (4.3, 7.8) to (3.0 mm, 5.6°), compared to state‐of‐the‐art methods.