Multiple transfer standard for calibration and characterization of test setups for LED lamps and luminaires in industry
- 2 February 2018
- journal article
- research article
- Published by IOP Publishing in Metrologia
- Vol. 55 (2) , S37-S42
Abstract
Proper characterization of test setups used in industry for testing and traceable measurement of lighting devices by the substitution method is an important task. According to new standards for testing LED lamps, luminaires and modules, uncertainty budgets are requested because in many cases the properties of the device under test differ from the transfer standard used, which may cause significant errors, for example if a LED-based lamp is tested or calibrated in an integrating sphere which was calibrated with a tungsten lamp. This paper introduces a multiple transfer standard, which was designed not only to transfer a single calibration value (e.g. luminous flux) but also to characterize test setups used for LED measurements with additional provided and calibrated output features to enable the application of the new standards.Keywords
Funding Information
- European Association of National Metrology Institutes (EMRP ENG 62 MESaiL)
This publication has 3 references indexed in Scilit:
- Robot goniophotometry at PTBMetrologia, 2015
- Photometry and colorimetry of reference LEDs by using a compact goniophotometerMAPAN, 2009
- Messunsicherheit bei nicht korrigierten systematischen Messabweichungen Uncertainty of Measurement with Uncorrected Systematic DeviationsTM - Technisches Messen, 2008