ASArmin Sperling

Armin Sperling

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Armin Sperling has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Uncertainty analysis of spectral flux measurement using Monte Carlo simulation

    by Şenel Yaran, Zühal Alpaslan Kösemen, Çağri Kaan Akkan, Hilal Fatmagül Nişancı, Udo Krüger, Armin Sperling

    In photometry, spectrally integrated quantities are commonly used, and their uncertainties are calculated using classical approaches. Since determining correlations at different wavelengths and effects on spectrally integrated quantities is rather complex, a noise modification of the spectral value using Monte Carlo simulation was applied to estimate unknown correlations in the uncertainty of total luminous flux based on integrated spectral luminous flux values. For this aim, an LED with 6500 K correlated colour temperature was measured in an integrated sphere flux measurement system. The correlations between the measurements at different wavelengths were analysed, and the uncertainty boundaries of the integrated quantity and total luminous flux were obtained.

  • UNCERTAINTY EVALUATION OF HORTICULTURAL LEDs AND MONTE CARLO SIMULATION APPROACH

    by Z. Alpaslan Kösemen, Ş. Yaran, H. Nişancı, A. Sperling, Ç. Akkan

    In the fields of photometry and radiometry, spectral measurements play a crucial role in determining various parameters. The photometric parameters like total luminous flux, colour coordinates, etc. are attained by integrating spectral quantities. The integrated quantity uncertainty analyses can be complex for the calculation by GUM approach. Uncertainty analysis including the correlations effect can be done by Monte Carlo simulation. This study shows both approaches, i.e. with and without correlations, for the uncertainty analysis of the flux of a horticultural LED.

  • Open Access

    Evaluation of different general V(λ) mismatch indices of photometers for LED-based light sources in general lighting applications

    by Udo Krüger, Alejandro Ferrero, Ville Mantela, Anders Thorseth, Klaus Trampert, Olivier Pellegrino, Armin Sperling

    The general V(λ) mismatch index, f 1 ′ , of a photometer quantifies the deviation between its determined relative spectral responsivity, s rel λ , and its nominal responsivity, the spectral luminous efficiency function for photopic vision, V(λ). LED-based light sources now dominate in general lighting, displacing incandescent and fluorescent lamps. Furthermore, the calibration of photometers will very likely see the replacement of the reference CIE standard illuminant A with CIE reference spectrum L41. The article evaluates the consequences. Should we also change the definition of the general V(λ) mismatch index? Based on performance criteria, the individual indices are evaluated using various datasets with the help of statistical analyses. As a result, the authors can conclude that the current definition works very well even under changed calibration and application conditions and does not need to be changed. Other evaluated indices for a new index definition perform only slightly better in some cases, but do not generate generally better properties.


  • The SI Unit Candela

    by Armin Sperling, Stefan Kück

    The history of photometry, the measurement of light—and thus also the root of the basic unit for the luminous intensity, goes back to the seventeenth century. The theoretical foundations are provided by Johann H. Lambert in his treatise on photometry around 1760. With industrialization in the nineteenth century, there is an increasing demand for stable reference light sources for the measurement of light and for an reliable definition of the unit for light. But it is not until the middle of the twentieth century that the basic prerequisites had been created to use a common, internationally recognized unit, the Candela, as a measure of the visible light. The following article describes the basics and the boundary conditions that arise for the unit candela from the revision of the SI.


  • Multiple transfer standard for calibration and characterization of test setups for LED lamps and luminaires in industry

    by Armin Sperling, Maic Meyer, Stefan Pendsa, Werner Jordan, Elena Revtova, Tuomas Poikonen, Dominique Renoux, Peter Blattner

    Proper characterization of test setups used in industry for testing and traceable measurement of lighting devices by the substitution method is an important task. According to new standards for testing LED lamps, luminaires and modules, uncertainty budgets are requested because in many cases the properties of the device under test differ from the transfer standard used, which may cause significant errors, for example if a LED-based lamp is tested or calibrated in an integrating sphere which was calibrated with a tungsten lamp. This paper introduces a multiple transfer standard, which was designed not only to transfer a single calibration value (e.g. luminous flux) but also to characterize test setups used for LED measurements with additional provided and calibrated output features to enable the application of the new standards.


  • Open Access

    Impact of Improved Calibration of a NEO HySpex VNIR-1600 Sensor on Remote Sensing of Water Depth

    by Karim Lenhard, Andreas Baumgartner, Peter Gege, Saulius Nevas, Stefan Nowy, Armin Sperling

    This paper investigates at the example of bathymetry how much an application can profit from comprehensive characterizations required for an improved calibration of data from a state-of-the-art commercial hyperspectral sensor. A NEO HySpex VNIR-1600 sensor is used for this paper, and the improvements are based on measurements of sensor properties not covered by the manufacturer, in particular, detector nonlinearity and stray light. This additional knowledge about the instrument is used to implement corrections for nonlinearity, stray light, spectral smile distortion and nonuniform spectral bandwidth and to base the radiometric calibration on a SI-traceable radiance standard. Bathymetry is retrieved from a data take from the lake Starnberg using WASI-2D. The results using the original and improved calibration procedures are compared with ground reference data, with an emphasis on the effect of stray-light correction. For our instrument, stray-light biases the detector response from 416-500 nm up to 8% and from 700-760 nm up to 5%. Stray-light-induced errors affect bathymetry mainly in water deeper than Secchi depth, whereas in shallower water, the dominant error source is the calibration accuracy of the light source used for radiometric calibration. Stray-light correction reduced the systematic error of water depth by 19% from Secchi depth to three times Secchi depth, whereas the relative standard deviation remained stable at 5%.