Dorsal Tangential View of the Wrist to Detect Screw Penetration to the Dorsal Cortex of the Distal Radius after Volar Fixed-Angle Plating
Authors:
- 7 January 2011
- journal article
- research article
- Published by SAGE Publications in HAND
- Vol. 6 (2) , 190-193
Abstract
Background: Extensor tendon irritation and attritional tendon ruptures are well-recognized complications, secondary to dorsal screw penetration following volar plating of the distal radius. Lateral and oblique views of the wrist have limited ability to detect such penetration, particularly at the ulnar side of the Lister's tubercle. In this report, we conducted an intraoperative fluoroscopic study to determine dorsal screw penetration in various positions of the wrist/forearm and compared the standard radiographic views (lateral, supination, and pronation views) with dorsal tangential view of the wrist. Materials and Method: Standard lateral, oblique (in pronation and supination), and dorsal tangential views were obtained in 27 consecutive patients undergoing fixation a distal radius fractures using a volar plate. The number of penetrating screws in each dorsal compartment (second, third, fourth) was recorded in each view. Dorsal tangential view was obtained using a mini C-arm intraoperatively and sending the beam parallel to the dorsal aspect of the wrist in transverse plane. Results: Of the 125 distal screws, 8 screws were seen to be penetrating the dorsal cortex in lateral and oblique views, whereas 11 screws were detected in dorsal tangential view. Conclusion: The screw penetration to the third dorsal compartment was missed in standard views, but visualized in dorsal tangential view. We recommend the use of dorsal tangential view in addition to standard lateral and oblique views during volar plating of the distal radius.Keywords
This publication has 18 references indexed in Scilit:
- Computer tomography aided 3D analysis of the distal dorsal radius surface and the effects on volar plate osteosynthesisJournal of Hand Surgery (European Volume), 2009
- Radiographic Evaluation of Dorsal Screw Penetration after Volar Fixed-Angle Plating of the Distal Radius: A Cadaveric StudyHAND, 2007
- Complications Following Internal Fixation of Unstable Distal Radius Fracture With a Palmar Locking-PlateJournal of Orthopaedic Trauma, 2007
- Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fracturesThe Journal of Bone and Joint Surgery. British volume, 2006
- Two Potential Causes of EPL Rupture after Distal Radius Volar Plate FixationClinical Orthopaedics and Related Research, 2006
- The 45° pronated oblique view for volar fixed-angle plating of distal radius fracturesThe Journal of Hand Surgery, 2004
- Complications of the AO/ASIF titanium distal radius plate system (π plate) in internal fixation of the distal radius: A brief reportThe Journal of Hand Surgery, 1998
- Extensor pollicis longus rupture at the tip of a prominent fixation screw: Report of three casesThe Journal of Hand Surgery, 1993
- Rupture of extensor pollicis longus following fixation of a distal radius fractureInjury, 1989
- Late rupture of the extensor pollicis longus tendon: The case against attritionJournal of Hand Surgery (European Volume), 1988