A Quality Control System for Automated Prostate Segmentation on T2-Weighted MRI
Open Access
- 18 September 2020
- journal article
- research article
- Published by MDPI AG in Diagnostics
- Vol. 10 (9) , 714
Abstract
Computer-aided detection and diagnosis (CAD) systems have the potential to improve robustness and efficiency compared to traditional radiological reading of magnetic resonance imaging (MRI). Fully automated segmentation of the prostate is a crucial step of CAD for prostate cancer, but visual inspection is still required to detect poorly segmented cases. The aim of this work was therefore to establish a fully automated quality control (QC) system for prostate segmentation based on T2-weighted MRI. Four different deep learning-based segmentation methods were used to segment the prostate for 585 patients. First order, shape and textural radiomics features were extracted from the segmented prostate masks. A reference quality score (QS) was calculated for each automated segmentation in comparison to a manual segmentation. A least absolute shrinkage and selection operator (LASSO) was trained and optimized on a randomly assigned training dataset (N = 1756, 439 cases from each segmentation method) to build a generalizable linear regression model based on the radiomics features that best estimated the reference QS. Subsequently, the model was used to estimate the QSs for an independent testing dataset (N = 584, 146 cases from each segmentation method). The mean ± standard deviation absolute error between the estimated and reference QSs was 5.47 ± 6.33 on a scale from 0 to 100. In addition, we found a strong correlation between the estimated and reference QSs (rho = 0.70). In conclusion, we developed an automated QC system that may be helpful for evaluating the quality of automated prostate segmentations.Keywords
Funding Information
- Norwegian University of Science and Technology (NTNU) Biotechnology (81770928)
- The Research Council of Norway (295013)
- The Liaison Committee between the Central Norway Regional Health Authority and the Norwegian University of Science and Technology (90368401, 90265300)
This publication has 38 references indexed in Scilit:
- Evaluation of prostate segmentation algorithms for MRI: The PROMISE12 challengeMedical Image Analysis, 2014
- Computer-Aided Detection of Prostate Cancer in MRIIEEE Transactions on Medical Imaging, 2014
- Cancer statistics, 2014CA: A Cancer Journal for Clinicians, 2014
- Prostate Cancer: Computer-aided Diagnosis with Multiparametric 3-T MR Imaging—Effect on Observer PerformanceRadiology, 2013
- MRI of the prostate: Interobserver agreement compared with histopathologic outcome after radical prostatectomyEuropean Journal of Radiology, 2012
- ESUR prostate MR guidelines 2012European Radiology, 2012
- Use of gray value distribution of run lengths for texture analysisPattern Recognition Letters, 1990
- Textural features corresponding to textural propertiesIEEE Transactions on Systems, Man, and Cybernetics, 1989
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Neighboring gray level dependence matrix for texture classificationComputer Vision, Graphics, and Image Processing, 1983