Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mohammed R. S. Sunoqrot has a total of 46 co-authors. Here are the top co-authors by number of shared publications:

  • Tone Frost Bathen

    Department of Circulation and Medical Imaging, Norwegian University of Science and Technology (NTNU), Trondheim, Norway.

    8 shared publications
  • Mattijs Elschot

    Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Trondheim, Norway

    7 shared publications
  • Sverre Langørgen

    Department of Radiology and Nuclear Medicine, St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway

    4 shared publications
  • Helena Bertilsson

    Department of Cancer Research and Molecular Medicine, NTNU-Norwegian University of Science and Technology, Trondheim, Norway

    3 shared publications
  • Kirsten M. Selnæs

    3 shared publications
  • Mattijs Elschot

    Department of Circulation and Medical Imaging, Norwegian University of Science and Technology (NTNU), Trondheim, Norway

    3 shared publications

Latest Publications

  • Open Access

    Prospective validation of an AI software for detecting clinically significant prostate cancer on biparametric MRI

    by Mohammed R. S. Sunoqrot, Rebecca Segre, Gabriel A. Nketiah, Petter Davik, Torill A. E. Sjøbakk, Sverre Langørgen, Mattijs Elschot, Tone F. Bathen

    Objectives: To evaluate the feasibility and safety (primary endpoints), and performance (secondary endpoint) of a new artificial intelligence (AI) software for detecting clinically significant prostate cancer (csPCa) on biparametric MRI (bpMRI) compared to an expert radiologist. Materials and methods: In this prospective study at St. Olavs Hospital, Norway (December 2023–October 2024), 89 consecutive biopsy-naïve men underwent bpMRI for suspected PCa. Scans were interpreted by a radiologist using PI-RADS v2.1 and a radiomics-based AI software. Biopsies were obtained from all radiologist- and/or AI-identified lesions. csPCa was defined as ISUP ≥ 2. Feasibility was defined by a < 10% software-failure rate, and safety by the absence of serious adverse device effects (SADEs). Performance was evaluated with ROC, free-response ROC, and precision-recall curves. Results: Among 89 patients eligible for primary endpoints evaluation, the software demonstrated feasibility (7% failure rate) and safety (no SADEs). Among 76 eligible for secondary endpoint evaluation (median age 68 years [IQR: 63–73]), csPCa was found in 51% (39/76). Patient-level, software achieved an area under the ROC curve [95% CI] of 0.90 [0.83, 0.96] versus 0.86 [0.76, 0.93] ( p = 0.25). At a retrospectively optimized threshold matching the radiologist’s patient-level sensitivity at PI-RADS 3 (0.92), software achieved specificity of 0.68 [0.57, 0.78] versus 0.57 [0.46, 0.68] ( p = 0.29). Lesion-level, software achieved higher average precision (0.61 [0.52, 0.71] vs. 0.56 [0.46, 0.67]) and lower average false-positive per patient (0.33 [0.22, 0.43] vs. 0.41 [0.30, 0.52]) at the optimized threshold. Conclusion: The software was feasible and safe, and diagnostic performance showed potential to reduce unnecessary biopsies. Critical relevance statement: This clinically validated artificial intelligence software enables feasible and safe detection of clinically significant prostate cancer on biparametric MRI, with demonstrated potential to reduce unnecessary biopsies and improve diagnostic accuracy, indicating potential for integration into clinical prostate cancer care. Key Points: A fully automated radiomics software for clinically significant prostate cancer detection on biparametric MRI was prospectively clinically validated. The software demonstrated feasibility and safety, with potential to reduce unnecessary biopsies and improve diagnostic accuracy. The investigated radiomics software has the potential for integration into clinical prostate cancer care. Graphical


  • Optimizing Federated Learning Configurations for MRI Prostate Segmentation and Cancer Detection: A Simulation Study

    by Ashkan Moradi, Fadila Zerka, Joeran Sander Bosma, Mohammed R. S. Sunoqrot, Bendik S. Abrahamsen, Derya Yakar, Jeroen Geerdink, Henkjan Huisman, Tone Frost Bathen, Mattijs Elschot

    Federated learning enables collaborative model training, enhancing the performance and generalizability of trained models for MRI-based prostate gland segmentation and clinically significant prostate cancer detection compared with locally trained models.


  • Open Access

    The impact of pre-processing and disease characteristics on reproducibility of T2-weighted MRI radiomics features

    by Dyah Ekashanti Octorina Dewi, Mohammed R. S. Sunoqrot, Gabriel Addio Nketiah, Elise Sandsmark, Guro F. Giskeødegård, Sverre Langørgen, Helena Bertilsson, Mattijs Elschot, Tone Frost Bathen

    Purpose: To evaluate the reproducibility of radiomics features derived via different pre-processing settings from paired T2-weighted imaging (T2WI) prostate lesions acquired within a short interval, to select the setting that yields the highest number of reproducible features, and to evaluate the impact of disease characteristics (i.e., clinical variables) on features reproducibility.Materials and methods: A dataset of 50 patients imaged using T2WI at 2 consecutive examinations was used. The dataset was pre-processed using 48 different settings. A total of 107 radiomics features were extracted from manual delineations of 74 lesions. The inter-scan reproducibility of each feature was measured using the intra-class correlation coefficient (ICC), with ICC values > 0.75 considered good. Statistical differences were assessed using Mann–WhitneyUand Kruskal–Wallis tests.Results: The pre-processing parameters strongly influenced the reproducibility of radiomics features of T2WI prostate lesions. The setting that yielded the highest number of features (25 features) with high reproducibility was the relative discretization with a fixed bin number of 64, no signal intensity normalization, and outlier filtering by excluding outliers. Disease characteristics did not significantly impact the reproducibility of radiomics features.Conclusion: The reproducibility of T2WI radiomics features was significantly influenced by pre-processing parameters, but not by disease characteristics. The selected pre-processing setting yielded 25 reproducible features.


  • Open Access

    A comparison of Generative Adversarial Networks for automated prostate cancer detection on T2-weighted MRI

    by Alexandros Patsanis, Mohammed R.S. Sunoqrot, Sverre Langørgen, Hao Wang, Kirsten M. Selnæs, Helena Bertilsson, Tone F. Bathen, Mattijs Elschot


  • Open Access

    CROPro: a tool for automated cropping of prostate magnetic resonance images

    by Alexandros Patsanis, Mohammed R. S. Sunoqrot, Tone F. Bathen, Mattijs Elschot

    PurposeTo bypass manual data preprocessing and optimize deep learning performance, we developed and evaluated CROPro, a tool to standardize automated cropping of prostate magnetic resonance (MR) images.ApproachCROPro enables automatic cropping of MR images regardless of patient health status, image size, prostate volume, or pixel spacing. CROPro can crop foreground pixels from a region of interest (e.g., prostate) with different image sizes, pixel spacing, and sampling strategies. Performance was evaluated in the context of clinically significant prostate cancer (csPCa) classification. Transfer learning was used to train five convolutional neural network (CNN) and five vision transformer (ViT) models using different combinations of cropped image sizes (64 × 64, 128 × 128, and 256 × 256 pixels2), pixel spacing (0.2 × 0.2, 0.3 × 0.3, 0.4 × 0.4, and 0.5 × 0.5 mm2), and sampling strategies (center, random, and stride cropping) over the prostate. T2-weighted MR images (N = 1475) from the online available PI-CAI challenge were used to train (N = 1033), validate (N = 221), and test (N = 221) all models.ResultsAmong CNNs, SqueezeNet with stride cropping (image size: 128 × 128, pixel spacing: 0.2 × 0.2 mm2) achieved the best classification performance (0.678 ± 0.006). Among ViTs, ViT-H/14 with random cropping (image size: 64 × 64 and pixel spacing: 0.5 × 0.5 mm2) achieved the best performance (0.756 ± 0.009). Model performance depended on the cropped area, with optimal size generally larger with center cropping (∼40 cm2) than random/stride cropping (∼10 cm2).ConclusionWe found that csPCa classification performance of CNNs and ViTs depends on the cropping settings. We demonstrated that CROPro is well suited to optimize these settings in a standardized manner, which could improve the overall performance of deep learning models.


  • Open Access

    Artificial intelligence for prostate MRI: open datasets, available applications, and grand challenges

    by Mohammed R. S. Sunoqrot, Anindo Saha, Matin Hosseinzadeh, Mattijs Elschot, Henkjan Huisman

    Artificial intelligence (AI) for prostate magnetic resonance imaging (MRI) is starting to play a clinical role for prostate cancer (PCa) patients. AI-assisted reading is feasible, allowing workflow reduction. A total of 3,369 multi-vendor prostate MRI cases are available in open datasets, acquired from 2003 to 2021 in Europe or USA at 3 T (n = 3,018; 89.6%) or 1.5 T (n = 296; 8.8%), 346 cases scanned with endorectal coil (10.3%), 3,023 (89.7%) with phased-array surface coils; 412 collected for anatomical segmentation tasks, 3,096 for PCa detection/classification; for 2,240 cases lesions delineation is available and 56 cases have matching histopathologic images; for 2,620 cases the PSA level is provided; the total size of all open datasets amounts to approximately 253 GB. Of note, quality of annotations provided per dataset highly differ and attention must be paid when using these datasets (e.g., data overlap). Seven grand challenges and commercial applications from eleven vendors are here considered. Few small studies provided prospective validation. More work is needed, in particular validation on large-scale multi-institutional, well-curated public datasets to test general applicability. Moreover, AI needs to be explored for clinical stages other than detection/characterization (e.g., follow-up, prognosis, interventions, and focal treatment).


  • Open Access

    The Reproducibility of Deep Learning-Based Segmentation of the Prostate Gland and Zones on T2-Weighted MR Images

    by Mohammed R. S. Sunoqrot, Kirsten M. Selnæs, Elise Sandsmark, Sverre Langørgen, Helena Bertilsson, Tone F. Bathen, Mattijs Elschot

    Volume of interest segmentation is an essential step in computer-aided detection and diagnosis (CAD) systems. Deep learning (DL)-based methods provide good performance for prostate segmentation, but little is known about the reproducibility of these methods. In this work, an in-house collected dataset from 244 patients was used to investigate the intra-patient reproducibility of 14 shape features for DL-based segmentation methods of the whole prostate gland (WP), peripheral zone (PZ), and the remaining prostate zones (non-PZ) on T2-weighted (T2W) magnetic resonance (MR) images compared to manual segmentations. The DL-based segmentation was performed using three different convolutional neural networks (CNNs): V-Net, nnU-Net-2D, and nnU-Net-3D. The two-way random, single score intra-class correlation coefficient (ICC) was used to measure the inter-scan reproducibility of each feature for each CNN and the manual segmentation. We found that the reproducibility of the investigated methods is comparable to manual for all CNNs (14/14 features), except for V-Net in PZ (7/14 features). The ICC score for segmentation volume was found to be 0.888, 0.607, 0.819, and 0.903 in PZ; 0.988, 0.967, 0.986, and 0.983 in non-PZ; 0.982, 0.975, 0.973, and 0.984 in WP for manual, V-Net, nnU-Net-2D, and nnU-Net-3D, respectively. The results of this work show the feasibility of embedding DL-based segmentation in CAD systems, based on multiple T2W MR scans of the prostate, which is an important step towards the clinical implementation.


  • Open Access

    A Quality Control System for Automated Prostate Segmentation on T2-Weighted MRI

    by Mohammed R. S. Sunoqrot, Kirsten M. Selnæs, Elise Sandsmark, Gabriel A. Nketiah, Olmo Zavala-Romero, Radka Stoyanova, Tone F. Bathen, Mattijs Elschot

    Computer-aided detection and diagnosis (CAD) systems have the potential to improve robustness and efficiency compared to traditional radiological reading of magnetic resonance imaging (MRI). Fully automated segmentation of the prostate is a crucial step of CAD for prostate cancer, but visual inspection is still required to detect poorly segmented cases. The aim of this work was therefore to establish a fully automated quality control (QC) system for prostate segmentation based on T2-weighted MRI. Four different deep learning-based segmentation methods were used to segment the prostate for 585 patients. First order, shape and textural radiomics features were extracted from the segmented prostate masks. A reference quality score (QS) was calculated for each automated segmentation in comparison to a manual segmentation. A least absolute shrinkage and selection operator (LASSO) was trained and optimized on a randomly assigned training dataset (N = 1756, 439 cases from each segmentation method) to build a generalizable linear regression model based on the radiomics features that best estimated the reference QS. Subsequently, the model was used to estimate the QSs for an independent testing dataset (N = 584, 146 cases from each segmentation method). The mean ± standard deviation absolute error between the estimated and reference QSs was 5.47 ± 6.33 on a scale from 0 to 100. In addition, we found a strong correlation between the estimated and reference QSs (rho = 0.70). In conclusion, we developed an automated QC system that may be helpful for evaluating the quality of automated prostate segmentations.


  • Open Access

    Automated reference tissue normalization of T2-weighted MR images of the prostate using object recognition

    by Mohammed R. S. Sunoqrot, Gabriel A. Nketiah, Kirsten M. Selnæs, Tone F. Bathen, Mattijs Elschot

    Objectives: To develop and evaluate an automated method for prostate T2-weighted (T2W) image normalization using dual-reference (fat and muscle) tissue.Materials and methods: Transverse T2W images from the publicly available PROMISE12 (N = 80) and PROSTATEx (N = 202) challenge datasets, and an in-house collected dataset (N = 60) were used. Aggregate channel features object detectors were trained to detect reference fat and muscle tissue regions, which were processed and utilized to normalize the 3D images by linear scaling. Mean prostate pseudo T2 values after normalization were compared to literature values. Inter-patient histogram intersections of voxel intensities in the prostate were compared between our approach, the original images, and other commonly used normalization methods. Healthy vs. malignant tissue classification performance was compared before and after normalization.Results: The prostate pseudo T2 values of the three tested datasets (mean ± standard deviation = 78.49 ± 9.42, 79.69 ± 6.34 and 79.29 ± 6.30 ms) corresponded well to T2 values from literature (80 ± 34 ms). Our normalization approach resulted in significantly higher (p < 0.001) inter-patient histogram intersections (median = 0.746) than the original images (median = 0.417) and most other normalization methods. Healthy vs. malignant classification also improved significantly (p < 0.001) in peripheral (AUC 0.826 vs. 0.769) and transition (AUC 0.743 vs. 0.678) zones.Conclusion: An automated dual-reference tissue normalization of T2W images could help improve the quantitative assessment of prostate cancer.


  • Open Access

    Relative Enhanced Diffusivity in Prostate Cancer: Protocol Optimization and Diagnostic Potential

    by Daniel C. Billdal, Peter T. While, Kirsten M. Selnæs, Mohammed R. S. Sunoqrot, Sverre Langørgen, Helena Bertilsson, Tone F. Bathen, Mattijs Elschot

    Background: Relative enhanced diffusivity (RED) is a potential biomarker for indirectly measuring perfusion in tissue using diffusion‐weighted magnetic resonance imaging (MRI) with 3 b values.Purpose: To optimize the RED MRI protocol for the prostate, and to investigate its potential for prostate cancer (PCa) diagnosis.Study Type: Prospective.Population: Ten asymptomatic healthy volunteers and 35 patients with clinical suspicion of PCa.Sequence: 3T T2‐ and diffusion‐weighted MRI with b values: b = 0, 50, [100], 150, [200], 250, [300], 400, 800 s/mm2 (values in brackets were only used for patients).Assessment: Monte Carlo simulations were performed to assess noise sensitivity of RED as a function of intermediate b value. Volunteers were scanned 3 times to assess repeatability of RED. Patient data were used to investigate RED's potential for discriminating between biopsy‐confirmed cancer and healthy tissue, and between true and false positive radiological findings.Statistical Tests: Within‐subject coefficient of variation (WCV) to assess repeatability and receiver‐operating characteristic curve analysis and logistic regression to assess diagnostic performance of RED.Results: The repeatability was acceptable (WCV = 0.2‐0.3) for all intermediate b values tested, apart from b = 50 s/mm2 (WCV = 0.3‐0.4). The simulated RED values agreed well with the experimental data, showing that an intermediate b value between 150‐250 s/mm2 minimizes noise sensitivity in both peripheral zone (PZ) and transition zone (TZ). RED calculated with the b values 0, 150 and 800 s/mm2 was significantly higher in tumors than in healthy tissue in both PZ (P < 0.001, area under the curve [AUC] = 0.85) and PZ + TZ (P < 0.001, AUC = 0.84). RED was shown to aid apparent diffusion coefficient (ADC) in differentiating between false‐positive findings and true‐positive PCa in the PZ (AUC; RED = 0.71, ADC = 0.74, RED+ADC = 0.77).Data Conclusion: RED is a repeatable biomarker that may have value for prostate cancer diagnosis. An intermediate b value in the range of 150‐250 s/mm2 minimizes the influence of noise and maximizes repeatability.Level of Evidence: 2Technical Efficacy Stage: 1J. Magn. Reson. Imaging 2020;51:1900–1910.