Abstract
The masonry code shear strength equation over-predicts the shear capacity of partially grouted masonry shear walls. To compensate for the overprediction, the code adopted the grouted shear wall factor yg for which the value is 0.75 for partially grouted walls. There have been hundreds of masonry shear wall specimens tested and, collectively, this large pool of data covers a wide range of possible design parameters, variables, and combinations thereof. A few studies have been conducted using a portion of the available data pool to investigate the accuracy and robustness of the shear strength equation for fully and partially grouted walls. To date, however, no comprehensive study has been conducted on both grouted wall types using the full available data. This article presents a statistical analysis conducted using the full data set and a discussion on the nominal shear strength of partially grouted masonry walls. The statistical power of the analysis is significantly higher than that of previous studies because of the larger number of samples used. The study used meta-analysis to determine the mean shear strength ratios for fully and partially grouted masonry shear walls in relation to the shear strength equation. The analysis of the wider range of values for each design parameter or variable more wholly accounted for the variability introduced by each parameter or variable and increased the generalizability of the results to a larger portion of the population.