Fernando S. Fonseca
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Fernando S. Fonseca has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Guilherme Aris Parsekian
UFSCar
6 shared publications - Ad. T. Vermeltfoort
Eindhoven University of Technology
1 shared publication Adriana Baptista
Federal University of São Carlos – UFSCar
1 shared publication- Adriana Baptista
Universidade Federal de São Carlos, Brasil
1 shared publication - Ailton Freire
Instituto Federal do Piaui, Brazil
1 shared publication - André Lübeck
Universidade Federal de Santa Maria
1 shared publication
Latest Publications
- 28 January 2023
- Published by Elsevier in Construction and Building Materials
- Vol. 368
Effect of size and water content on the compressive strength of mortar
- 28 January 2023
- Published by Elsevier in Construction and Building Materials
- Vol. 368
Effect of size and water content on the compressive strength of mortar
- Open Access
- 1 January 2021
- Published by FapUNIFESP (SciELO) in Matéria (Rio de Janeiro)
- Vol. 26 (3)
Improved testing procedures to assess the physical and mechanical properties of ceramic blocks
- 1 January 2021
- Published by FapUNIFESP (SciELO) in Matéria (Rio de Janeiro)
- Vol. 26 (3)
Open AccessImproved testing procedures to assess the physical and mechanical properties of ceramic blocks
- Open Access
- 1 June 2020
- Published by FapUNIFESP (SciELO) in Revista IBRACON de Estruturas e Materiais
- Vol. 13 (3) , 578-592
Experimental and numerical characterization of the interface between concrete masonry block and mortar
Masonry is a construction system that has been used since the beginning of civilization and is still used throughout the world. The finite element method is a recent development that allows complex problems, including structural masonry problems, to be solved. A vast amount of literature exists on finite element modeling, using software such as ABAQUS, to represent experimental masonry models. Based on this established pattern, an experimental and analytical research program was designed and implemented. Thus, a set of tests was conducted to determine the compressive and tensile strengths of the masonry components, i.e., block, mortar, and grout. Bond wrench tests, diagonal tension tests, and horizontal joint shear tests were conducted to characterize the interface between the blocks and the mortar. A finite element model was then developed to represent the physical models and the general conclusion is that the finite element model was able to represent reasonably well the physical models.
- 1 June 2020
- Published by FapUNIFESP (SciELO) in Revista IBRACON de Estruturas e Materiais
- Vol. 13 (3) , 578-592
Open AccessExperimental and numerical characterization of the interface between concrete masonry block and mortar
Masonry is a construction system that has been used since the beginning of civilization and is still used throughout the world. The finite element method is a recent development that allows complex problems, including structural masonry problems, to be solved. A vast amount of literature exists on finite element modeling, using software such as ABAQUS, to represent experimental masonry models. Based on this established pattern, an experimental and analytical research program was designed and implemented. Thus, a set of tests was conducted to determine the compressive and tensile strengths of the masonry components, i.e., block, mortar, and grout. Bond wrench tests, diagonal tension tests, and horizontal joint shear tests were conducted to characterize the interface between the blocks and the mortar. A finite element model was then developed to represent the physical models and the general conclusion is that the finite element model was able to represent reasonably well the physical models.
- 1 January 2019
- Published by Springer Nature
- p. 532-539
A Proposed Test to Evaluate Efflorescence Potential of Ceramic Blocks
- 1 January 2019
- Published by Springer Nature
- p. 532-539
A Proposed Test to Evaluate Efflorescence Potential of Ceramic Blocks
- Open Access
- 1 April 2018
- Published by FapUNIFESP (SciELO) in Revista IBRACON de Estruturas e Materiais
- Vol. 11 (2) , 279-295
Stiffness plasticity degradation of masonry mortar under compression: preliminar results
The main goal of this research is to determine the mechanical properties of bedding mortar by assessing the mortar damage onset, the stiffness plasticity degradation and the apparent Poisson´s ratio under compression. Two mortar types, 1:0.5:4 and 1:1:6 (cement:lime:sand ratio), were used and tested at 28 days; specimens had diameter-to-height (d/h) ratios of 0.3 and 1.0. These diameter-to-height (d/h) ratios were chosen to evaluate the effect of confinement caused by the friction between the steel plates of the testing machine and the sample. Numerical models were developed, and their response compared with the experimental results. From the experimental results, it was concluded that there are meaningful differences in their responses with weak and strong mortar types and different d/h ratios. The d/h ratio influences the relationship between the stress and strength and the apparent Poisson´s ratio of the specimen, which is defined herein as the ratio of the horizontal to vertical strain, regardless of cracking of the specimen. The mortar damage onset and stiffness plasticity degradation for both mortar types and d/h ratio are different and depend on the stress/strength ratio level. All samples with a d/h ratio of 0.3 show a constant decrease in the volumetric strain until failure but with negligible expansion on the horizontal deformation. In contrast, samples with a d/h ratio of 1.0 present an increase of stiffness after development of the first crack, which causes the increase of the sample volume. Numerical simulation and experimental results for mortar 1:0.5:4 with a d/h ratio of 0.3 are similar until approximately 10 MPa, after which the numerical results diverge from the experimental results. For the d/h ratio of 1.0, the vertical strain results are also similar, but the horizontal strains results near failure are very different. The model can not represent the nonlinear increase of the horizontal strain near failure probably because the crack propagation and the stiffness plasticity degradation could not be controlled. For mortar 1:1:6, vertical strains from numerical and experimental results are similar, but again the model can not reproduce the nonlinear increase of horizontal strain near failure.
- 1 April 2018
- Published by FapUNIFESP (SciELO) in Revista IBRACON de Estruturas e Materiais
- Vol. 11 (2) , 279-295
Open AccessStiffness plasticity degradation of masonry mortar under compression: preliminar results
The main goal of this research is to determine the mechanical properties of bedding mortar by assessing the mortar damage onset, the stiffness plasticity degradation and the apparent Poisson´s ratio under compression. Two mortar types, 1:0.5:4 and 1:1:6 (cement:lime:sand ratio), were used and tested at 28 days; specimens had diameter-to-height (d/h) ratios of 0.3 and 1.0. These diameter-to-height (d/h) ratios were chosen to evaluate the effect of confinement caused by the friction between the steel plates of the testing machine and the sample. Numerical models were developed, and their response compared with the experimental results. From the experimental results, it was concluded that there are meaningful differences in their responses with weak and strong mortar types and different d/h ratios. The d/h ratio influences the relationship between the stress and strength and the apparent Poisson´s ratio of the specimen, which is defined herein as the ratio of the horizontal to vertical strain, regardless of cracking of the specimen. The mortar damage onset and stiffness plasticity degradation for both mortar types and d/h ratio are different and depend on the stress/strength ratio level. All samples with a d/h ratio of 0.3 show a constant decrease in the volumetric strain until failure but with negligible expansion on the horizontal deformation. In contrast, samples with a d/h ratio of 1.0 present an increase of stiffness after development of the first crack, which causes the increase of the sample volume. Numerical simulation and experimental results for mortar 1:0.5:4 with a d/h ratio of 0.3 are similar until approximately 10 MPa, after which the numerical results diverge from the experimental results. For the d/h ratio of 1.0, the vertical strain results are also similar, but the horizontal strains results near failure are very different. The model can not represent the nonlinear increase of the horizontal strain near failure probably because the crack propagation and the stiffness plasticity degradation could not be controlled. For mortar 1:1:6, vertical strains from numerical and experimental results are similar, but again the model can not reproduce the nonlinear increase of horizontal strain near failure.
- Open Access
- 1 November 2017
- Published by FapUNIFESP (SciELO) in Revista IBRACON de Estruturas e Materiais
- Vol. 10 (6) , 1273-1319
Compressive strength of masonry constructed with high strength concrete blocks
Although the use of high strength concrete blocks for the construction of tall buildings is becoming common in Brazil, their mechanical properties and behavior are not fully understood. The literature shows a gap in experimental studies with the use of high strength concrete blocks, i.e., those with compressive strength greater than 16 MPa. The work presented herein was conducted in order to study the behavior of high strength structural masonry. Therefore, the compressive strength and modulus of elasticity of concrete block walls tested under axial load were assessed. The specimens included grouted and ungrouted walls and walls with a mid-height bond beam; ungrouted walls were constructed with face-shell and full mortar bedding. The walls were built and tested in the laboratory of CESP and in the Structures Laboratory of the UNESP Civil Engineering Department in Ilha Solteira (NEPAE). Concrete blocks with nominal compressive strength of 16 (B1), 24 (B2) and 30 (B3) MPa were used. Ungrouted masonry walls had a height of 220 cm and a width of 120 cm while grouted masonry walls had a height of 220 cm and a width of 80 cm. Traditional Portland cement, sand and lime mortar was used. The testing program included 36 blocks, 18 prisms, 9 ungrouted walls (6 with face-shell mortar bedding and 3 with full mortar bedding), 9 grouted masonry walls, and 12 ungrouted walls with a bond beam at mid-height. The experimental results were used to determine the compressive strength ratio between masonry units, prisms and masonry walls. The analyses included assessing the cracking pattern, the mode of failure and the stress-strain curve of the masonry walls. Tests results indicate that the prism-to-unit strength ratio varies according to the block strength; that face-shell mortar bedding is suitable for high strength concrete masonry; and that 20% resistance decrease for face-shell mortar bedding when compared with full mortar bedding is a conservative consideration. The results also show that using a bond beam at the mid-height of the wall does not lead to a compressive strength decreased but it changes the failure mode and the shape of the stress-strain curve. In addition, the results show that estimating E = 800 fp is conservative for ungrouted masonry walls but reasonably accurate for grouted masonry walls and that there is no reason to limit the value of E to a maximum value of 16 GPa. Furthermore, the results show that, for design purposes, a wall-to-prism strength ratio value of 0.7 may be used for high strength concrete masonry.
- 1 November 2017
- Published by FapUNIFESP (SciELO) in Revista IBRACON de Estruturas e Materiais
- Vol. 10 (6) , 1273-1319
Open AccessCompressive strength of masonry constructed with high strength concrete blocks
Although the use of high strength concrete blocks for the construction of tall buildings is becoming common in Brazil, their mechanical properties and behavior are not fully understood. The literature shows a gap in experimental studies with the use of high strength concrete blocks, i.e., those with compressive strength greater than 16 MPa. The work presented herein was conducted in order to study the behavior of high strength structural masonry. Therefore, the compressive strength and modulus of elasticity of concrete block walls tested under axial load were assessed. The specimens included grouted and ungrouted walls and walls with a mid-height bond beam; ungrouted walls were constructed with face-shell and full mortar bedding. The walls were built and tested in the laboratory of CESP and in the Structures Laboratory of the UNESP Civil Engineering Department in Ilha Solteira (NEPAE). Concrete blocks with nominal compressive strength of 16 (B1), 24 (B2) and 30 (B3) MPa were used. Ungrouted masonry walls had a height of 220 cm and a width of 120 cm while grouted masonry walls had a height of 220 cm and a width of 80 cm. Traditional Portland cement, sand and lime mortar was used. The testing program included 36 blocks, 18 prisms, 9 ungrouted walls (6 with face-shell mortar bedding and 3 with full mortar bedding), 9 grouted masonry walls, and 12 ungrouted walls with a bond beam at mid-height. The experimental results were used to determine the compressive strength ratio between masonry units, prisms and masonry walls. The analyses included assessing the cracking pattern, the mode of failure and the stress-strain curve of the masonry walls. Tests results indicate that the prism-to-unit strength ratio varies according to the block strength; that face-shell mortar bedding is suitable for high strength concrete masonry; and that 20% resistance decrease for face-shell mortar bedding when compared with full mortar bedding is a conservative consideration. The results also show that using a bond beam at the mid-height of the wall does not lead to a compressive strength decreased but it changes the failure mode and the shape of the stress-strain curve. In addition, the results show that estimating E = 800 fp is conservative for ungrouted masonry walls but reasonably accurate for grouted masonry walls and that there is no reason to limit the value of E to a maximum value of 16 GPa. Furthermore, the results show that, for design purposes, a wall-to-prism strength ratio value of 0.7 may be used for high strength concrete masonry.
- Open Access
- 1 December 2016
- Published by The Masonry Society in The Masonry Society Journal
- Vol. 34 (1)
The Masonry Market is Booming in Brazil- Why?
This paper is motivated by the keynote presentation at the 12th North American Masonry Conference in Denver, Colorado in 2015. It gives an overview on how engineered masonry became the preferable construction system to build thousands of mid-rise apartment buildings for the 200-million residents of Brazil, South America. Recently, the peak production of hollow blocks was reached with more than two billion units delivered in a single year. This paper presents reasons for the current prevalent use of structural masonry, which was introduced in Brazil during the late 1960s. One of the first cases presented is the substitution from a reinforced concrete wall system to a reinforced masonry system without changing the in-place foundation. Some of the reasons for masonry´s popularity are related to design. Another advantage is a favorable layout. Each story of these multistory buildings is a “box system” with several interlocked structural masonry walls in both directions with a top rigid reinforced concrete slab diaphragm. Load demand includes wind loads from 30 to 45 m/s (67 to 100 mph) but no significant seismic loads. Different tailored-to-masonry design models and software include vertical load distribution among interlocked walls while others use “frame” models to provide lateral stability. Others advantages of structural masonry are related to materials availability and quality control. Blocks of more than 50 MPa (7,250 psi) are readily available. Grout and mortar specifications vary per the block strength, providing higher prism strengths. Code specification demands testing of mortar, grout, block and prism at every floor and includes verification of several construction tolerances. However, the reasons above do not wholly explain why masonry is so often used. The main reason is the recognition of a highly precise and straightforward method to plan and construct structural masonry systems. Masonry has the ability to be adapted to various types of buildings and aesthetic needs, allowing different architectural expressions. In addition, the speed of construction can be balanced with various construction needs. Furthermore, masonry technology, including materials, workmanship and equipment, is available through both small and large businesses, and do not require high initial investments. If the building layout is favorable, as most residential mid-height projects are, the overall construction cost will be less compared to other systems
- 1 December 2016
- Published by The Masonry Society in The Masonry Society Journal
- Vol. 34 (1)
Open AccessThe Masonry Market is Booming in Brazil- Why?
This paper is motivated by the keynote presentation at the 12th North American Masonry Conference in Denver, Colorado in 2015. It gives an overview on how engineered masonry became the preferable construction system to build thousands of mid-rise apartment buildings for the 200-million residents of Brazil, South America. Recently, the peak production of hollow blocks was reached with more than two billion units delivered in a single year. This paper presents reasons for the current prevalent use of structural masonry, which was introduced in Brazil during the late 1960s. One of the first cases presented is the substitution from a reinforced concrete wall system to a reinforced masonry system without changing the in-place foundation. Some of the reasons for masonry´s popularity are related to design. Another advantage is a favorable layout. Each story of these multistory buildings is a “box system” with several interlocked structural masonry walls in both directions with a top rigid reinforced concrete slab diaphragm. Load demand includes wind loads from 30 to 45 m/s (67 to 100 mph) but no significant seismic loads. Different tailored-to-masonry design models and software include vertical load distribution among interlocked walls while others use “frame” models to provide lateral stability. Others advantages of structural masonry are related to materials availability and quality control. Blocks of more than 50 MPa (7,250 psi) are readily available. Grout and mortar specifications vary per the block strength, providing higher prism strengths. Code specification demands testing of mortar, grout, block and prism at every floor and includes verification of several construction tolerances. However, the reasons above do not wholly explain why masonry is so often used. The main reason is the recognition of a highly precise and straightforward method to plan and construct structural masonry systems. Masonry has the ability to be adapted to various types of buildings and aesthetic needs, allowing different architectural expressions. In addition, the speed of construction can be balanced with various construction needs. Furthermore, masonry technology, including materials, workmanship and equipment, is available through both small and large businesses, and do not require high initial investments. If the building layout is favorable, as most residential mid-height projects are, the overall construction cost will be less compared to other systems
- Open Access
- 1 December 2015
- Published by The Masonry Society in The Masonry Society Journal
- Vol. 33 (1)
Nominal Shear Strength of Partially Grouted Masonry Walls
The masonry code shear strength equation over-predicts the shear capacity of partially grouted masonry shear walls. To compensate for the overprediction, the code adopted the grouted shear wall factor yg for which the value is 0.75 for partially grouted walls. There have been hundreds of masonry shear wall specimens tested and, collectively, this large pool of data covers a wide range of possible design parameters, variables, and combinations thereof. A few studies have been conducted using a portion of the available data pool to investigate the accuracy and robustness of the shear strength equation for fully and partially grouted walls. To date, however, no comprehensive study has been conducted on both grouted wall types using the full available data. This article presents a statistical analysis conducted using the full data set and a discussion on the nominal shear strength of partially grouted masonry walls. The statistical power of the analysis is significantly higher than that of previous studies because of the larger number of samples used. The study used meta-analysis to determine the mean shear strength ratios for fully and partially grouted masonry shear walls in relation to the shear strength equation. The analysis of the wider range of values for each design parameter or variable more wholly accounted for the variability introduced by each parameter or variable and increased the generalizability of the results to a larger portion of the population.
- 1 December 2015
- Published by The Masonry Society in The Masonry Society Journal
- Vol. 33 (1)
Open AccessNominal Shear Strength of Partially Grouted Masonry Walls
The masonry code shear strength equation over-predicts the shear capacity of partially grouted masonry shear walls. To compensate for the overprediction, the code adopted the grouted shear wall factor yg for which the value is 0.75 for partially grouted walls. There have been hundreds of masonry shear wall specimens tested and, collectively, this large pool of data covers a wide range of possible design parameters, variables, and combinations thereof. A few studies have been conducted using a portion of the available data pool to investigate the accuracy and robustness of the shear strength equation for fully and partially grouted walls. To date, however, no comprehensive study has been conducted on both grouted wall types using the full available data. This article presents a statistical analysis conducted using the full data set and a discussion on the nominal shear strength of partially grouted masonry walls. The statistical power of the analysis is significantly higher than that of previous studies because of the larger number of samples used. The study used meta-analysis to determine the mean shear strength ratios for fully and partially grouted masonry shear walls in relation to the shear strength equation. The analysis of the wider range of values for each design parameter or variable more wholly accounted for the variability introduced by each parameter or variable and increased the generalizability of the results to a larger portion of the population.