Investigation into activation of accelerators at various synchrotron radiation facilities in Japan
Authors:
Open Access
- 13 October 2021
- journal article
- research article
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 59 (5) , 543-554
Abstract
To establish systematic guidelines for accelerator decommissioning, a large-scale activation survey was conducted at representative synchrotron radiation facilities in Japan. The neutron flux during accelerator operation was measured with various dosimeters. A Monte Carlo simulation was conducted for some facilities to verify the special neutron distribution and their spectra. Beam loss points, reflected as high-dose-rate areas, were identified by a whole-beamline survey with a survey meter, and the generated radionuclides and their activity were determined with a lanthanum bromide (LaBr3) scintillation spectrometer. In all facilities, the activation level was quite low. Whole-beamline tunnels made of concrete were not activated, and no radionuclides were detected except for natural nuclides. In addition, almost all beamline components were either not or minimally activated. Although the acceleration energy is very high for radiation synchrotron facilities, the generation of radioactive waste would be very low.Keywords
Funding Information
- Nuclear Regulation Authority (JPJ007057)
This publication has 25 references indexed in Scilit:
- Activation benchmark study at a 2.5 GeV electron acceleratorProgress in Nuclear Science and Technology, 2014
- JENDL-4.0: A New Library for Nuclear Science and EngineeringJournal of Nuclear Science and Technology, 2011
- Role of activation analysis for radiation control in accelerator facilitiesJournal of Radioanalytical and Nuclear Chemistry, 2008
- Evaluation of the radioactivity in concrete from accelerator facilitiesJournal of Radioanalytical and Nuclear Chemistry, 2007
- Improved detector response characterization method in ISOCS and LabSOCSJournal of Radioanalytical and Nuclear Chemistry, 2005
- Data WatchPediatric News, 2005
- Tritium activity induced in the accelerator building and its correlation to radioactivity of gamma-nuclidesJournal of Radioanalytical and Nuclear Chemistry, 2004
- Measurement of the Spatial Distribution of Neutrons in an Accelerator Room by the Combination of Activation Detectors and an Imaging PlateRadiation Safety Management, 2002
- Predicting Induced Radioactivity at High-Energy Electron AcceleratorsJournal of Nuclear Science and Technology, 2000
- Dose-equivalent response CR-39 track detector for personnel neutron dosimetryNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1991