Go Yoshida
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Go Yoshida has a total of 100 co-authors. Here are the top co-authors by number of shared publications:
Taichi Miura
Radiation Science Center, High Energy Accelerator Research Organization (KEK), Tsukuba-Ibaraki, Japan
12 shared publicationsAkihiro Toyoda
Radiation Science Center, High Energy Accelerator Research Organization (KEK), Tsukuba-Ibaraki, Japan
7 shared publicationsHajime Nakamura
Radiation Science Center, High Energy Accelerator Research Organization (KEK), Tsukuba-Ibaraki, Japan
7 shared publicationsKazuyoshi Masumoto
Radiation Science Center, High Energy Accelerator Research Organization (KEK), Tsukuba-Ibaraki, Japan
7 shared publicationsAtsushi Shinohara
Osaka University
6 shared publicationsHiroshi Matsumura
Radiation Science Center, High Energy Accelerator Research Organization (KEK), Tsukuba-Ibaraki, Japan
6 shared publications
Latest Publications
- Open Access
- 19 February 2024
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 61  (10) , 1298-1307
Activation level of the concrete building and pressure vessel in JAEA-Tokai tandem accelerator
- 19 February 2024
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 61  (10) , 1298-1307
Open AccessActivation level of the concrete building and pressure vessel in JAEA-Tokai tandem accelerator
- 9 March 2023
- Published by American Chemical Society (ACS) in ACS Earth and Space Chemistry
- Vol. 7  (4) , 699-711
Development of Nondestructive Elemental Analysis System for Hayabusa2 Samples Using Muonic X-rays
- 9 March 2023
- Published by American Chemical Society (ACS) in ACS Earth and Space Chemistry
- Vol. 7  (4) , 699-711
Development of Nondestructive Elemental Analysis System for Hayabusa2 Samples Using Muonic X-rays
- Open Access
- 13 October 2021
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 59  (5) , 543-554
Investigation into activation of accelerators at various synchrotron radiation facilities in Japan
To establish systematic guidelines for accelerator decommissioning, a large-scale activation survey was conducted at representative synchrotron radiation facilities in Japan. The neutron flux during accelerator operation was measured with various dosimeters. A Monte Carlo simulation was conducted for some facilities to verify the special neutron distribution and their spectra. Beam loss points, reflected as high-dose-rate areas, were identified by a whole-beamline survey with a survey meter, and the generated radionuclides and their activity were determined with a lanthanum bromide (LaBr3) scintillation spectrometer. In all facilities, the activation level was quite low. Whole-beamline tunnels made of concrete were not activated, and no radionuclides were detected except for natural nuclides. In addition, almost all beamline components were either not or minimally activated. Although the acceleration energy is very high for radiation synchrotron facilities, the generation of radioactive waste would be very low.
- 13 October 2021
- Published by Taylor & Francis in Journal of Nuclear Science and Technology
- Vol. 59  (5) , 543-554
Open AccessInvestigation into activation of accelerators at various synchrotron radiation facilities in Japan
To establish systematic guidelines for accelerator decommissioning, a large-scale activation survey was conducted at representative synchrotron radiation facilities in Japan. The neutron flux during accelerator operation was measured with various dosimeters. A Monte Carlo simulation was conducted for some facilities to verify the special neutron distribution and their spectra. Beam loss points, reflected as high-dose-rate areas, were identified by a whole-beamline survey with a survey meter, and the generated radionuclides and their activity were determined with a lanthanum bromide (LaBr3) scintillation spectrometer. In all facilities, the activation level was quite low. Whole-beamline tunnels made of concrete were not activated, and no radionuclides were detected except for natural nuclides. In addition, almost all beamline components were either not or minimally activated. Although the acceleration energy is very high for radiation synchrotron facilities, the generation of radioactive waste would be very low.
- 25 May 2020
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 325  (3) , 801-806
Investigation of variations in cobalt and europium concentrations in concrete to prepare for accelerator decommissioning
- 25 May 2020
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 325  (3) , 801-806
Investigation of variations in cobalt and europium concentrations in concrete to prepare for accelerator decommissioning
- 10 September 2019
- Published by Royal Society of Chemistry (RSC)
- p. 135-147
Simplified Method for Determining Residual Specific Activity in Activated Concrete of a PET-cyclotron Room Using a Survey Meter
An in situ method to determine the specific activity in concrete structures using a survey meter was established in this study for decommissioning accelerator rooms. This method is much simpler than the conventional sampling method that requires core boring. A survey meter (T-SP2, TAC Inc., Japan) was customised and equipped with a small detector probe, whose size allowed the design of a light-weight Pb shield. For dose rate measurement, a Pb shield thickness of 4.5 cm was enough to shield ambient γ-rays, and its weight (16 kg) was low enough for the device to be carried by a human. A calibration curve was obtained to quickly and easily convert the net contact dose rate on concrete into the specific activity in a PET cyclotron room. The specific activity detection limit for this device was lower than the clearance limit of 152Eu and 60Co in activated materials. Therefore, this method can be used for separating nonactivated concrete from activated concrete during decommissioning. A general correction factor for the slope of the calibration curve was also obtained for use at other accelerator facilities.
- 10 September 2019
- Published by Royal Society of Chemistry (RSC)
- p. 135-147
Simplified Method for Determining Residual Specific Activity in Activated Concrete of a PET-cyclotron Room Using a Survey Meter
An in situ method to determine the specific activity in concrete structures using a survey meter was established in this study for decommissioning accelerator rooms. This method is much simpler than the conventional sampling method that requires core boring. A survey meter (T-SP2, TAC Inc., Japan) was customised and equipped with a small detector probe, whose size allowed the design of a light-weight Pb shield. For dose rate measurement, a Pb shield thickness of 4.5 cm was enough to shield ambient γ-rays, and its weight (16 kg) was low enough for the device to be carried by a human. A calibration curve was obtained to quickly and easily convert the net contact dose rate on concrete into the specific activity in a PET cyclotron room. The specific activity detection limit for this device was lower than the clearance limit of 152Eu and 60Co in activated materials. Therefore, this method can be used for separating nonactivated concrete from activated concrete during decommissioning. A general correction factor for the slope of the calibration curve was also obtained for use at other accelerator facilities.
- 10 September 2019
- Published by Royal Society of Chemistry (RSC)
- p. 152-160
Investigation of Neutron-fluence Measurement Methods for Estimating Neutron-induced Activity from an Electrostatic Accelerator Source
Three methods to detect neutrons emitted from an electrostatic accelerator were examined. These were gold foil activation, thermoluminescent dosimeters (TLDs), and CR-39. The gold-foil activation method has previously been proven effective in the measurement of neutrons emitted from cyclotron sources. In the case of electrostatic accelerators, a greater amount of fast neutrons and a smaller amount of thermal neutrons are observed compared to a cyclotron accelerator. Therefore, the error in calculating the thermal neutron flux became unacceptably large. By comparison the CR-39 detectors were apparently unable to measure thermal neutrons well, because some tracks were also generated by fast neutrons causing a signal interference. In the case of TLDs, as the material was not sensitive to fast neutrons, it was not affected by them, and hence could adequately measure the thermal neutron flux. However, it was found that in some cases its measurements could be offset by the influence of high dose rate of gamma rays.
- 10 September 2019
- Published by Royal Society of Chemistry (RSC)
- p. 152-160
Investigation of Neutron-fluence Measurement Methods for Estimating Neutron-induced Activity from an Electrostatic Accelerator Source
Three methods to detect neutrons emitted from an electrostatic accelerator were examined. These were gold foil activation, thermoluminescent dosimeters (TLDs), and CR-39. The gold-foil activation method has previously been proven effective in the measurement of neutrons emitted from cyclotron sources. In the case of electrostatic accelerators, a greater amount of fast neutrons and a smaller amount of thermal neutrons are observed compared to a cyclotron accelerator. Therefore, the error in calculating the thermal neutron flux became unacceptably large. By comparison the CR-39 detectors were apparently unable to measure thermal neutrons well, because some tracks were also generated by fast neutrons causing a signal interference. In the case of TLDs, as the material was not sensitive to fast neutrons, it was not affected by them, and hence could adequately measure the thermal neutron flux. However, it was found that in some cases its measurements could be offset by the influence of high dose rate of gamma rays.
- 10 September 2019
- Published by Royal Society of Chemistry (RSC)
- p. 178-183
Quantitative Evaluation of Radioactivity in Concrete at PET Cyclotron Facility with Simple and Non-destructive Measurement
Accelerator operations often generate neutrons that may activate concrete in the accelerator room. When accelerators are decommissioned, the concrete will remain as radioactive waste. Not all of concrete in the room will be radioactive wastes, but at place with large amount of neutrons will be radioactive wastes. Therefore, it is very important to determine where and how many neutrons are generated during accelerator operation. We used gold foils to obtain this information in positron emission tomography (PET) cyclotron facilities. We obtained concrete core samples from a PET cyclotron to determine the amount of radioactivity contained in concrete. We obtained the operational parameters (particle, radioactive product, current, and operation time) of the PET cyclotron facility and estimated the radioactivity generated in concrete using the operational parameters and gold foil results. A comparison of the estimated and core sampling measurement results showed good agreement.
- 10 September 2019
- Published by Royal Society of Chemistry (RSC)
- p. 178-183
Quantitative Evaluation of Radioactivity in Concrete at PET Cyclotron Facility with Simple and Non-destructive Measurement
Accelerator operations often generate neutrons that may activate concrete in the accelerator room. When accelerators are decommissioned, the concrete will remain as radioactive waste. Not all of concrete in the room will be radioactive wastes, but at place with large amount of neutrons will be radioactive wastes. Therefore, it is very important to determine where and how many neutrons are generated during accelerator operation. We used gold foils to obtain this information in positron emission tomography (PET) cyclotron facilities. We obtained concrete core samples from a PET cyclotron to determine the amount of radioactivity contained in concrete. We obtained the operational parameters (particle, radioactive product, current, and operation time) of the PET cyclotron facility and estimated the radioactivity generated in concrete using the operational parameters and gold foil results. A comparison of the estimated and core sampling measurement results showed good agreement.
- 10 September 2019
- Published by Royal Society of Chemistry (RSC)
- p. 191-203
Evaluation of Different Gamma-ray Imaging Techniques for Visualisation of Induced Activity in Accelerator Magnets
Activated accelerator magnets were measured with three different types of commercially available gamma-ray imaging devices (pinhole, Compton scattering, and masked type) and the results were compared to simplify a distinction between activated/non-activated areas in the magnet during the decommissioning of an accelerator facility. In general, an activated magnet includes 60Co and emits gamma rays over 1 MeV; however, current devices are not designed to detect such high-energy photons. Our results showed that two devices could identify the location of highly activated areas, although they could not detect the total absorption peaks of the 1173 and 1333 keV photons from 60Co.
- 10 September 2019
- Published by Royal Society of Chemistry (RSC)
- p. 191-203
Evaluation of Different Gamma-ray Imaging Techniques for Visualisation of Induced Activity in Accelerator Magnets
Activated accelerator magnets were measured with three different types of commercially available gamma-ray imaging devices (pinhole, Compton scattering, and masked type) and the results were compared to simplify a distinction between activated/non-activated areas in the magnet during the decommissioning of an accelerator facility. In general, an activated magnet includes 60Co and emits gamma rays over 1 MeV; however, current devices are not designed to detect such high-energy photons. Our results showed that two devices could identify the location of highly activated areas, although they could not detect the total absorption peaks of the 1173 and 1333 keV photons from 60Co.
- 12 March 2019
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 320  (2) , 283-289
Initial quantum levels of captured muons in CO, CO2, and COS
- 12 March 2019
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 320  (2) , 283-289
Initial quantum levels of captured muons in CO, CO2, and COS
- Open Access
- 12 June 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1046  (1) , 012017
Evaluation of induced activity in various components of a PET-cyclotron
For decommissioning a cyclotron facility, it is important to evaluate the induced activity of the various components of the cyclotron; however, activation of the metal components has been rarely investigated. In this study, two types of cyclotrons were examined; one is a proton acceleration type using a deflector, and another is a hydride ion (H-) acceleration type using a carbon stripper foil for beam extraction to the target port. The samples were obtained from various metal components such as the yoke, sector magnet, coil, and vacuum chamber by the core boring method, and the depth distribution of the radioactivity was determined via a germanium semiconductor detector. The activities of 54 Mn and 60 Co were detected from the surface to a deeper site of the yoke and sector magnet. Most of the observed activities of the cyclotron components were higher than the clearance levels, suggesting that a clearance system should not be applied to the yoke and sector magnet. In the case of a highactivity sample, we have to wait for 30 years to reach the clearance level.
- 12 June 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1046  (1) , 012017
Open AccessEvaluation of induced activity in various components of a PET-cyclotron
For decommissioning a cyclotron facility, it is important to evaluate the induced activity of the various components of the cyclotron; however, activation of the metal components has been rarely investigated. In this study, two types of cyclotrons were examined; one is a proton acceleration type using a deflector, and another is a hydride ion (H-) acceleration type using a carbon stripper foil for beam extraction to the target port. The samples were obtained from various metal components such as the yoke, sector magnet, coil, and vacuum chamber by the core boring method, and the depth distribution of the radioactivity was determined via a germanium semiconductor detector. The activities of 54 Mn and 60 Co were detected from the surface to a deeper site of the yoke and sector magnet. Most of the observed activities of the cyclotron components were higher than the clearance levels, suggesting that a clearance system should not be applied to the yoke and sector magnet. In the case of a highactivity sample, we have to wait for 30 years to reach the clearance level.