Three‐dimensional arbitrary voxel shapes in spectroscopy with submillisecond TEs
- 31 January 2012
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 25 (8) , 1000-1006
Abstract
A novel spectroscopic method for submillisecond TEs and three‐dimensional arbitrarily shaped voxels was developed and applied to phantom and in vivo measurements, with additional parallel excitation (PEX) implementation. A segmented spherical shell excitation trajectory was used in combination with appropriate radiofrequency weights for target selection in three dimensions. Measurements in a two‐compartment phantom realized a TE of 955 µs, excellent spectral quality and comparable signal‐to‐noise ratios between accelerated (R = 2) and nonaccelerated modes. The two‐compartment model allowed a comparison of the spectral suppression qualities of the method and, although outer volume signals were suppressed by factors of 1434 and 2246 compared with the theoretical unsuppressed case for the clinical and PEX modes, respectively, incomplete suppression of the outer volume (935 cm3 compared with a target volume of 5.86 cm3) resulted in a spectral contamination of 10.2% and 6.5% compared with the total signal. The method was also demonstrated in vivo in human brain on a clinical system at TE = 935 µs with good signal‐to‐noise ratio and spatial and spectral selection, and included LCModel relative quantification analysis. Eight metabolites showed significant fitting accuracy, including aspartate, N‐acetylaspartylglutamate, glutathione and glutamate. Copyright © 2012 John Wiley & Sons, Ltd.Keywords
Funding Information
- German Federal Ministry of Education and Research (13 N9208)
This publication has 28 references indexed in Scilit:
- Consequences of T2 relaxation during half‐pulse slice selection for ultrashort TE imagingMagnetic Resonance in Medicine, 2010
- B1 mapping by Bloch‐Siegert shiftMagnetic Resonance in Medicine, 2010
- Parallel excitation in the human brain at 9.4 T counteracting k‐space errors with RF pulse designMagnetic Resonance in Medicine, 2009
- Difference spectroscopy using PRESS asymmetry: application to glutamate, glutamine, and myo-inositolNMR in Biomedicine, 2009
- In vivo detection of serine in the human brain by proton magnetic resonance spectroscopy (1H‐MRS) at 7 TeslaMagnetic Resonance in Medicine, 2009
- Designing multichannel, multidimensional, arbitrary flip angle RF pulses using an optimal control approachMagnetic Resonance in Medicine, 2008
- Estimation of metabolite concentrations from localized in vivo proton NMR spectraMagnetic Resonance in Medicine, 1993
- A linear class of large-tip-angle selective excitation pulsesJournal of Magnetic Resonance (1969), 1989
- A k-space analysis of small-tip-angle excitationJournal of Magnetic Resonance (1969), 1989
- Localized proton spectroscopy using stimulated echoesJournal of Magnetic Resonance (1969), 1987