Jeff Snyder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jeff Snyder has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Maxim Zaitsev
Division of Medical Physics, Department of Radiology, University Medical Center Freiburg, Faculty of Medicine University of Freiburg Freiburg Germany
2 shared publications Alan H. Wilman
Department of Physics, University of Alberta, Edmonton, Alta., Canada
1 shared publicationAlan Wilman
1 shared publicationChris C. Hanstock
Department of Biomedical Engineering, University of Alberta, Edmonton, Alta., Canada
1 shared publicationIulius Dragonu
Department of Radiology, Medical Physics University Medical Center Freiburg Freiburg Germany
1 shared publicationJürgen Hennig
Department of Radiology, Medical Physics University Medical Center Freiburg Freiburg Germany
1 shared publication
Latest Publications
- 31 January 2012
- Published by Wiley in NMR in Biomedicine
- Vol. 25 (8) , 1000-1006
Three‐dimensional arbitrary voxel shapes in spectroscopy with submillisecond TEs
A novel spectroscopic method for submillisecond TEs and three‐dimensional arbitrarily shaped voxels was developed and applied to phantom and in vivo measurements, with additional parallel excitation (PEX) implementation. A segmented spherical shell excitation trajectory was used in combination with appropriate radiofrequency weights for target selection in three dimensions. Measurements in a two‐compartment phantom realized a TE of 955 µs, excellent spectral quality and comparable signal‐to‐noise ratios between accelerated (R = 2) and nonaccelerated modes. The two‐compartment model allowed a comparison of the spectral suppression qualities of the method and, although outer volume signals were suppressed by factors of 1434 and 2246 compared with the theoretical unsuppressed case for the clinical and PEX modes, respectively, incomplete suppression of the outer volume (935 cm3 compared with a target volume of 5.86 cm3) resulted in a spectral contamination of 10.2% and 6.5% compared with the total signal. The method was also demonstrated in vivo in human brain on a clinical system at TE = 935 µs with good signal‐to‐noise ratio and spatial and spectral selection, and included LCModel relative quantification analysis. Eight metabolites showed significant fitting accuracy, including aspartate, N‐acetylaspartylglutamate, glutathione and glutamate. Copyright © 2012 John Wiley & Sons, Ltd.
- 31 January 2012
- Published by Wiley in NMR in Biomedicine
- Vol. 25 (8) , 1000-1006
Three‐dimensional arbitrary voxel shapes in spectroscopy with submillisecond TEs
A novel spectroscopic method for submillisecond TEs and three‐dimensional arbitrarily shaped voxels was developed and applied to phantom and in vivo measurements, with additional parallel excitation (PEX) implementation. A segmented spherical shell excitation trajectory was used in combination with appropriate radiofrequency weights for target selection in three dimensions. Measurements in a two‐compartment phantom realized a TE of 955 µs, excellent spectral quality and comparable signal‐to‐noise ratios between accelerated (R = 2) and nonaccelerated modes. The two‐compartment model allowed a comparison of the spectral suppression qualities of the method and, although outer volume signals were suppressed by factors of 1434 and 2246 compared with the theoretical unsuppressed case for the clinical and PEX modes, respectively, incomplete suppression of the outer volume (935 cm3 compared with a target volume of 5.86 cm3) resulted in a spectral contamination of 10.2% and 6.5% compared with the total signal. The method was also demonstrated in vivo in human brain on a clinical system at TE = 935 µs with good signal‐to‐noise ratio and spatial and spectral selection, and included LCModel relative quantification analysis. Eight metabolites showed significant fitting accuracy, including aspartate, N‐acetylaspartylglutamate, glutathione and glutamate. Copyright © 2012 John Wiley & Sons, Ltd.
- Open Access
- 30 June 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 67 (2) , 300-309
Selective excitation of two-dimensional arbitrarily shaped voxels with parallel excitation in spectroscopy
Parallel excitation is being studied intensively for applications in MR imaging and in particular for selecting arbitrary shapes as regions of interest. In this work, parallel excitation was applied to arbitrarily shaped voxel selection in spectroscopy and investigated for different excitation k‐space trajectories (radial, rectilinear, and spiral) and acceleration factors. Each trajectory was segmented into multiple excitations to increase the overall bandwidth during target selection. Acceleration by parallel excitation was used to decrease the number of segments. Evaluation of spatial and spectral localization of the target of interest was performed in simulation and phantom experiments, and was compared with the point resolved spectroscopy (PRESS) experiment with standard voxels. The selective excitation experiments demonstrated excellent spatial localization and a broad frequency response, although PRESS was superior in direct comparisons with respect to signal‐to‐noise ratio (SNR) and outer volume suppression. Extensive SNR variation was observed dependent on trajectory (8%–90%), with the preferred radial case producing approximately 40%–60% SNR of the PRESS case. Accelerated trajectories at R = 4 provided comparable artifact signal and target excitation accuracy compared with their nonaccelerated counterparts; however, further acceleration (R = 8) resulted in increased artifact (33% increase at R = 8). Magn Reson Med, 2012.
- 30 June 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 67 (2) , 300-309
Open AccessSelective excitation of two-dimensional arbitrarily shaped voxels with parallel excitation in spectroscopy
Parallel excitation is being studied intensively for applications in MR imaging and in particular for selecting arbitrary shapes as regions of interest. In this work, parallel excitation was applied to arbitrarily shaped voxel selection in spectroscopy and investigated for different excitation k‐space trajectories (radial, rectilinear, and spiral) and acceleration factors. Each trajectory was segmented into multiple excitations to increase the overall bandwidth during target selection. Acceleration by parallel excitation was used to decrease the number of segments. Evaluation of spatial and spectral localization of the target of interest was performed in simulation and phantom experiments, and was compared with the point resolved spectroscopy (PRESS) experiment with standard voxels. The selective excitation experiments demonstrated excellent spatial localization and a broad frequency response, although PRESS was superior in direct comparisons with respect to signal‐to‐noise ratio (SNR) and outer volume suppression. Extensive SNR variation was observed dependent on trajectory (8%–90%), with the preferred radial case producing approximately 40%–60% SNR of the PRESS case. Accelerated trajectories at R = 4 provided comparable artifact signal and target excitation accuracy compared with their nonaccelerated counterparts; however, further acceleration (R = 8) resulted in increased artifact (33% increase at R = 8). Magn Reson Med, 2012.
- 1 March 2010
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 203 (1) , 66-72
Field strength dependence of PRESS timings for simultaneous detection of glutamate and glutamine from 1.5 to 7T
- 1 March 2010
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 203 (1) , 66-72
Field strength dependence of PRESS timings for simultaneous detection of glutamate and glutamine from 1.5 to 7T
- 1 October 2009
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 200 (2) , 245-250
Spectral editing of weakly coupled spins using variable flip angles in PRESS constant echo time difference spectroscopy: Application to GABA
- 1 October 2009
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 200 (2) , 245-250
Spectral editing of weakly coupled spins using variable flip angles in PRESS constant echo time difference spectroscopy: Application to GABA