Caries detection under composite restorations by laser fluorescence and digital radiography
- 16 December 2012
- journal article
- research article
- Published by Springer Nature in Clinical Oral Investigations
- Vol. 17 (9) , 2079-2084
Abstract
Objectives The objective of this study is to assess the potential of DIAGNOdent readings in detecting carious lesions under composite resin restorations in comparison with digital radiography. Materials and methods One hundred extracted third molars were visually selected: 50 with and 50 without carious lesions. Class I occlusal cavities were prepared. In the carious group, caries were left on the floor of cavities before composite resin restoration. The occlusal surface relevant to the caries position in the carious group and a counterfeit point in the non-carious group were marked for DIAGNOdent reading. Teeth were fixed in a plaster box. Digital radiographs were taken and examined by four observers. Definitive diagnosis of caries was based on a histological assessment. Diagnostic accuracy for each method was expressed by the area under the receiver operating characteristic (ROC) curve. Differences between the areas under the ROC curves were assessed using the McNemar test. Results The respective sensitivity (95 % confidence interval (%CI)) and specificity (95 %CI) of DIAGNOdent were 0.74 (0.66–0.83) and 0.84 (0.76–0.92). The respective average diagnostic performance values for digital radiographs assessed by four observers were 0.54 (0.36–0.72) and 0.77 (0.65–0.86). The respective ROC values for DIAGNOdent and digital radiographs based on four observers were 0.79 and 0.65. Cohen’s kappa statistic revealed a moderate to substantial agreement among interobserver reliabilities (k = 0.60–0.77). Conclusions There were no statistically significant differences between DIAGNOdent and digital radiographs for the detection of dental caries under composite restoration (p value > 0.05). Clinical relevance DIAGNOdent was developed to detect caries on occlusal surfaces and was tested for caries adjacent to filling materials. This study demonstrated the use of DIAGNOdent in detecting caries under old composite restorations.Keywords
This publication has 35 references indexed in Scilit:
- Diagnostic accuracy of different imaging modalities in detection of proximal cariesDentomaxillofacial Radiology, 2010
- Comparison of digital systems and conventional dental film for the detection of approximal enamel cariesDentomaxillofacial Radiology, 2010
- Effect of monitor display on detection of approximal caries lesions in digital radiographsDentomaxillofacial Radiology, 2009
- In situ and in vitro comparison of laser fluorescence with visual inspection in detecting occlusal caries lesionsLasers in Medical Science, 2009
- Clinical diagnosis of fissure caries with conventional and laser-induced fluorescence techniquesLasers in Medical Science, 2009
- A comparative evaluation of DIAGNOdent with visual and radiography for detection of occlusal caries: An in vitro studyIndian Journal of Dental Research, 2009
- The intra/inter-examiner reproducibility of the new DIAGNOdent Pen on occlusal sitesJournal of Dentistry, 2007
- Evaluation of Several Techniques for the Detection of Secondary Caries Adjacent to Amalgam RestorationsCaries Research, 2004
- Comparison of standard and task-specific enhancement of Digora®storage phosphor images for approximal caries diagnosisDentomaxillofacial Radiology, 2003
- Performance and Reproducibility of a Laser Fluorescence System for Detection of Occlusal Caries in vitroCaries Research, 1999