Automated Spectroscopic Tissue Classification in Colorectal Surgery
- 3 February 2015
- journal article
- research article
- Published by SAGE Publications in Surgical Innovation
- Vol. 22 (6) , 557-567
Abstract
Background. In colorectal surgery, detecting ureters and mesenteric arteries is of utmost importance to prevent iatrogenic injury and to facilitate intraoperative decision making. A tool enabling ureter- and artery-specific image enhancement within (and possibly through) surrounding adipose tissue would facilitate this need, especially during laparoscopy. To evaluate the potential of hyperspectral imaging in colorectal surgery, we explored spectral tissue signatures using single-spot diffuse reflectance spectroscopy (DRS). As hyperspectral cameras with silicon (Si) and indium gallium arsenide (InGaAs) sensor chips are becoming available, we investigated spectral distinctive features for both sensor ranges. Methods. In vivo wide-band (wavelength range 350-1830 nm) DRS was performed during open colorectal surgery. From the recorded spectra, 36 features were extracted at predefined wavelengths: 18 gradients and 18 amplitude differences. For classification of respectively ureter and artery in relation to surrounding adipose tissue, the best distinctive feature was selected using binary logistic regression for Si- and InGaAs-sensor spectral ranges separately. Classification performance was evaluated by leave-one-out cross-validation. Results. In 10 consecutive patients, 253 spectra were recorded on 53 tissue sites (including colon, adipose tissue, muscle, artery, vein, ureter). Classification of ureter versus adipose tissue revealed accuracy of 100% for both Si range and InGaAs range. Classification of artery versus surrounding adipose tissue revealed accuracies of 95% (Si) and 89% (InGaAs). Conclusions. Intraoperative DRS showed that Si and InGaAs sensors are equally suited for automated classification of ureter versus surrounding adipose tissue. Si sensors seem better suited for classifying artery versus mesenteric adipose tissue. Progress toward hyperspectral imaging within this field is promising.Keywords
This publication has 36 references indexed in Scilit:
- Management of Anastomotic Leakage in a Nationwide Cohort of Colonic Cancer PatientsJournal of the American College of Surgeons, 2014
- Application of a New Dye for Near-Infrared Fluorescence Laparoscopy of the UretersDiseases of the Colon & Rectum, 2014
- Risk factors for anastomotic leakage and leak-related mortality after colonic cancer surgery in a nationwide auditBritish Journal of Surgery, 2014
- Intraoperative Near Infrared Fluorescence Guided Identification of the Ureters Using Low Dose Methylene Blue: A First in Human ExperienceJournal of Urology, 2013
- Ureteric injury: a challenging condition to diagnose and manageNature Reviews Urology, 2013
- Incidence of Iatrogenic Ureteral Injury After Laparoscopic ColectomyArchives of Surgery, 2012
- Near‐infrared laparoscopy for real‐time intra‐operative arterial and lymphatic perfusion imagingColorectal Disease, 2011
- Real-time, near-infrared, fluorescence-guided identification of the ureters using methylene blueSurgery, 2010
- The Angiographic Anatomy of the Small Arteries and Their Collaterals in Colorectal ResectionsAnnals of Surgery, 2010
- Changing Incidence and Etiology of Iatrogenic Ureteral InjuriesJournal of Urology, 1994