Development and validation of a GC‐C‐IRMS method for the confirmation analysis of pseudo‐endogenous glucocorticoids in doping control
- 25 November 2015
- journal article
- research article
- Published by Wiley in Drug Testing and Analysis
- Vol. 7 (11-12) , 1071-1078
Abstract
Glucocorticoids are included in the S9 section of the World Anti-doping Agency (WADA) prohibited list international standard. Some among them are pseudo-endogenous steroids, like cortisol and cortisone, which present the same chemical structure as endogenously produced steroids. We are proposing an analytical method based on gas chromatography coupled to isotope ratio mass spectrometry (GC-C-IRMS) which allows discrimination between endogenous and synthetic origin of the urinary metabolites of the pseudo-endogenous glucocorticoids. A preliminary purification treatment by high-performance liquid chromatography (HPLC) of the target compounds (TC) (i.e., cortisol, tetrahydrocortisone (THE) 5α-tetrahydrocortisone (aTHE), tetrahydrocortisol (THF), and 5α-tetrahydrocortisol (aTHF)) allows collection of extracts with adequate purity for the subsequent analysis by IRMS. A population of 40 urine samples was analyzed for the TC and for the endogenous reference compounds (ERC: i.e., 11-desoxy-tetrahydrocortisol (THS) or pregnanediol). For each sample, the difference between the delta values of the ERCs and TCs (Δδ values) were calculated and based on that, some decision limits for atypical findings are proposed. The limits are below 3% units except for cortisol. The fit to purpose of the method has been confirmed by the analysis of urine samples collected in two patients under treatment with 25 mg of cortisone acetate (p.o). The samples showed Δδ values higher than 3 for at least 24 h following administration depending on the TC considered. The method can easily be integrated into existing procedures already used for the HPLC purification and IRMS analysis of pseudo-endogenous steroids with androgenic/anabolic activity. Copyright © 2015 John Wiley & Sons, Ltd.Keywords
This publication has 17 references indexed in Scilit:
- A comprehensive procedure based on gas chromatography–isotope ratio mass spectrometry following high performance liquid chromatography purification for the analysis of underivatized testosterone and its analogues in human urineAnalytica Chimica Acta, 2012
- Carbon isotope ratio analysis of endogenous glucocorticoid urinary metabolites after cortisone acetate and adrenosterone administration for doping controlDrug Testing and Analysis, 2012
- Development of criteria for the detection of adrenosterone administration by gas chromatography‐mass spectrometry and gas chromatography‐combustion‐isotope ratio mass spectrometry for doping controlDrug Testing and Analysis, 2009
- Urine ratio of tetrahydrocortisol to tetrahydrodeoxycortisol to screen for the systemic administration of cortisone and hydrocortisoneForensic Science International, 2009
- Isotope ratio mass spectrometry analysis of the oxidation products of the main and minor metabolites of hydrocortisone and cortisone for antidoping controlsSteroids, 2009
- A screening method for the simultaneous detection of glucocorticoids, diuretics, stimulants, anti-oestrogens, beta-adrenergic drugs and anabolic steroids in human urine by LC-ESI-MS/MSAnalytical and Bioanalytical Chemistry, 2008
- A screening method for the detection of synthetic glucocorticosteroids in human urine by liquid chromatography–mass spectrometry based on class-characteristic fragmentation pathwaysAnalytical and Bioanalytical Chemistry, 2008
- Development and application of stable carbon isotope analysis to the detection of cortisol administration in cattleRapid Communications in Mass Spectrometry, 2007
- Determination of endogenous and synthetic glucocorticoids in human urine by gas chromatography–mass spectrometry following microwave-assisted derivatizationAnalytica Chimica Acta, 2003
- Detection of exogenous intake of natural corticosteroids by gas chromatography/combustion/isotope ratio mass spectrometry: application to misuse in sportRapid Communications in Mass Spectrometry, 2000