Mechanical properties of a cemented porous implant interface
Authors:
- Nicholas A BeckmannNBNicholas A Beckmann
- Rudi G BitschRBRudi G Bitsch
- Joern B SeegerJSJoern B Seeger
- Matthias Cm KlotzMKMatthias Cm Klotz
- Jan Philippe KretzerJKJan Philippe Kretzer
- Sebastian JaegerSJSebastian Jaeger
Open Access
- 5 May 2014
- journal article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 85 (5) , 531-537
Abstract
Revision arthroplasty often requires anchoring of prostheses to poor-quality or deficient bone stock. Recently, newer porous materials have been introduced onto the market as additional, and perhaps better, treatment options for revision arthroplasty. To date, there is no information on how these porous metals interface with bone cement. This is of clinical importance, since these components may require cementing to other prosthesis components and occasionally to bone. We created porous metal and bone cylinders of the same size and geometry and cemented them in a well-established standardized setting. These were then placed under tensile loading and torsional loading until failure was achieved. This permitted comparison of the porous metal/cement interface (group A) with the well-studied bone/cement interface (group B). The group A interface was statistically significantly stronger than the group B interface, despite having significantly reduced depth of cement penetration: it showed a larger maximum tensile force (effect size 2.7), superior maximum tensile strength (effect size 2.6), greater maximum torsional force (effect size 2.2), and higher rotational stiffness (effect size 1.5). The newer porous implants showed good interface properties when cemented using medium-viscosity bone cement. The axial and rotational mechanical strength of a porous metal/cement interface appeared to be greater than the strength of the standard bone/cement interface. These results indicate that cementing of porous implants can provide great stability in situations where it is needed.Keywords
This publication has 40 references indexed in Scilit:
- Low BMD affects initial stability and delays stem osseointegration in cementless total hip arthroplasty in womenActa Orthopaedica, 2012
- Can Tantalum Cones Provide Fixation in Complex Revision Knee Arthroplasty?Clinical Orthopaedics and Related Research, 2012
- Multi-axial loading micromechanics of the cement–bone interface in postmortem retrievals and lab-prepared specimensJournal of the Mechanical Behavior of Biomedical Materials, 2011
- The influence of cementing technique in hip resurfacing arthroplasty on the initial stability of the femoral componentInternational Orthopaedics, 2011
- Cementless acetabular revision: past, present, and futureInternational Orthopaedics, 2011
- Pulsed lavage improves fixation strength of cemented tibial componentsInternational Orthopaedics, 2010
- The mechanical effects of different levels of cement penetration at the cement–bone interfaceJournal of Biomechanics, 2010
- The effect of bone porosity on the shear strength of the bone–cement interfaceInternational Orthopaedics, 2008
- Tensile strength of the cement-bone interface depends on the amount of bone interdigitated with PMMA cementJournal of Biomechanics, 1997
- Trabecular bone exhibits fully linear elastic behavior and yields at low strainsJournal of Biomechanics, 1994