Pulsed lavage improves fixation strength of cemented tibial components
- 16 October 2010
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 35 (8) , 1165-1169
Abstract
Pulsatile lavage is purported to improve radiographic survival in cemented total knee arthroplasty (TKA). Similarly, a potential improvement of fixation strength of the tibial tray has been assumed based on the increased cement penetration. In this study, the influence of pulsed lavage on fixation strength of the tibial component and bone cement penetration was evaluated in six pairs of cadaveric specimens. Following surgical preparation, the tibial surface was irrigated using pulsatile lavage on one side of a pair, while on the other side syringe lavage was applied. All tibial components were implanted using the same cementing technique. Cement penetration and bone mineral density was assessed based on computed tomography data. Fixation strength of the tibial trays was determined by a pull-out test with a material testing machine. Median pull-out forces and cement penetration were significantly (p = 0.031) improved in the pulsed lavage group as compared to the syringe lavage group. Enhanced fixation strength is suggested as being a key to improved survival of the implant. Consequently, pulsatile lavage should be considered as a mandatory preparation step when cementing tibial components in TKA.Keywords
This publication has 33 references indexed in Scilit:
- Pulsed lavage reduces the incidence of radiolucent lines under the tibial tray of Oxford unicompartmental knee arthroplastyInternational Orthopaedics, 2009
- Follow-up of 11–16 years after modular fixed-bearing TKAInternational Orthopaedics, 2008
- Radiolucent lines below the tibial component of a total knee replacement (TKR) – a comparison between single-and two-stage cementation techniquesInternational Orthopaedics, 2007
- Tibial Component Fixation With CementClinical Orthopaedics and Related Research, 2003
- A randomised, controlled trial of cemented versus cementless press-fit condylar total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2002
- Early failures among 7,174 primary total knee replacements: A follow-up study from the Norwegian Arthroplasty Register 1994-2000Acta Orthopaedica, 2002
- Long-term registration has improved the quality of hip replacement: A review of the Swedish THR Register comparing 160,000 casesActa Orthopaedica, 2000
- Tensile strength of the cement-bone interface depends on the amount of bone interdigitated with PMMA cementJournal of Biomechanics, 1997
- Patellofemoral DisordersClinical Orthopaedics and Related Research, 1984
- Effect of cement pressure and bone strength on polymethylmethacrylate fixationJournal of Orthopaedic Research, 1983