A 3D-printed anatomical pancreas and kidney phantom for optimizing SPECT/CT reconstruction settings in beta cell imaging using 111In-exendin
Authors:
Open Access
- 7 December 2016
- journal article
- research article
- Published by Springer Nature in EJNMMI Physics
- Vol. 3 (1) , 1-14
Abstract
Quantitative single photon emission computed tomography (SPECT) is challenging, especially for pancreatic beta cell imaging with 111In-exendin due to high uptake in the kidneys versus much lower uptake in the nearby pancreas. Therefore, we designed a three-dimensionally (3D) printed phantom representing the pancreas and kidneys to mimic the human situation in beta cell imaging. The phantom was used to assess the effect of different reconstruction settings on the quantification of the pancreas uptake for two different, commercially available software packages. 3D-printed, hollow pancreas and kidney compartments were inserted into the National Electrical Manufacturers Association (NEMA) NU2 image quality phantom casing. These organs and the background compartment were filled with activities simulating relatively high and low pancreatic 111In-exendin uptake for, respectively, healthy humans and type 1 diabetes patients. Images were reconstructed using Siemens Flash 3D and Hermes Hybrid Recon, with varying numbers of iterations and subsets and corrections. Images were visually assessed on homogeneity and artefacts, and quantitatively by the pancreas-to-kidney activity concentration ratio. Phantom images were similar to clinical images and showed comparable artefacts. All corrections were required to clearly visualize the pancreas. Increased numbers of subsets and iterations improved the quantitative performance but decreased homogeneity both in the pancreas and the background. Based on the phantom analyses, the Hybrid Recon reconstruction with 6 iterations and 16 subsets was found to be most suitable for clinical use. This work strongly contributed to quantification of pancreatic 111In-exendin uptake. It showed how clinical images of 111In-exendin can be interpreted and enabled selection of the most appropriate protocol for clinical use.Keywords
Funding Information
- Seventh Framework Programme (222980)
This publication has 12 references indexed in Scilit:
- Technical Note: Characterization of custom 3D printed multimodality imaging phantomsMedical Physics, 2015
- 3D printer generated thorax phantom with mobile tumor for radiation dosimetryReview of Scientific Instruments, 2015
- Development of patient‐specific molecular imaging phantoms using a 3D printerMedical Physics, 2014
- Non-invasive quantification of the beta cell mass by SPECT with 111In-labelled exendinDiabetologia, 2014
- Quantitative SPECT/CT: SPECT joins PET as a quantitative imaging modalityEuropean Journal of Nuclear Medicine and Molecular Imaging, 2013
- An Evidence-Based Review of Quantitative SPECT Imaging and Potential Clinical ApplicationsJournal of Nuclear Medicine, 2013
- Development of a dynamic flow imaging phantom for dynamic contrast‐enhanced CTMedical Physics, 2011
- Absolute quantification in SPECTEuropean Journal of Nuclear Medicine and Molecular Imaging, 2011
- Reduction of Collimator Correction Artefacts with Bayesian Reconstruction in SpectInternational Journal of Molecular Imaging, 2010
- Physics in Nuclear MedicineMedical Physics, 2004