Eric P. Visser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Eric P. Visser has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Wim J. G. Oyen
Department of Radiology and Nuclear Medicine, Rijnstate Hospital, Arnhem, the Netherlands
2 shared publications Albert J. Arends
Department of Medical Physics, Catharina Hospital, Eindhoven, The Netherlands
1 shared publicationAntoi P. W. Meeuwis
Department of Radiology and Nuclear Medicine, Radboud University Medical Center, P.O. Box: 9101, 6500 HB, Nijmegen, The Netherlands
1 shared publicationAntoon T. M. Willemsen
Department of Nuclear Medicine & Molecular Imaging, University of Groningen, University Medical Centre Groningen, Groningen, The Netherlands
1 shared publication- Bianca A. W. Hoeben
Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, The Netherlands; Princess Máxima Center for Pediatric Oncology, Utrecht, The Netherlands
1 shared publication - Catherine Cheze Le Rest
LaTIM UMR 1101, Inserm, Brest, France; Nuclear Medicine, University Hospital of Poitiers, Poitiers, France
1 shared publication
Latest Publications
- 27 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 2 (1) , 33-40
Prognostic Value of Head and Neck Tumor Proliferative Sphericity From 3’-Deoxy-3’-[18F] Fluorothymidine Positron Emission Tomography
¹⁸F-FLT PET can be used for quantifying tumor proliferation and its changes during chemoradiotherapy (CRT) in head and neck squamous cell carcinoma (HNSCC). We investigated the complementary prognostic value of sphericity (one of several available 3D shape descriptors) and standard metrics in ¹⁸F-FLT PET images before and during CRT regarding 4-year disease-free survival (DFS). Forty-eight HNSCC patients treated with CRT underwent ¹⁸F-FLT PET/CT before and during CRT. Median follow-up was 52 months. Primary tumors were automatically delineated and characterized by extracting max and mean SUV, proliferative volume and associated sphericity. Prognostic value for DFS of clinical and imaging features was assessed using Kaplan-Meier survival analysis. In univariate analysis after correction for multiple testing, the per-treatment sphericity (HR=4.2, p=0.02) and SUVmean (HR=4.1, p=0.03) were prognostic factors, whereas none of the pre-treatment variables were significant. Reduction in SUVmax (HR=4, p=0.04) was also a prognostic factor, but not reduction of proliferative tumor volume. The best stratification of patients for DFS was achieved by combining per-treatment SUVmean and sphericity (HR=6.7, p<0.001). High sphericity combined with low mean ¹⁸F-FLT uptake during treatment were associated with better DFS. These results suggest the potential prognostic value of tumor characterization from ¹⁸F-FLT PET in HNSCC that may be further explored in larger cohorts.
- 27 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 2 (1) , 33-40
Prognostic Value of Head and Neck Tumor Proliferative Sphericity From 3’-Deoxy-3’-[18F] Fluorothymidine Positron Emission Tomography
¹⁸F-FLT PET can be used for quantifying tumor proliferation and its changes during chemoradiotherapy (CRT) in head and neck squamous cell carcinoma (HNSCC). We investigated the complementary prognostic value of sphericity (one of several available 3D shape descriptors) and standard metrics in ¹⁸F-FLT PET images before and during CRT regarding 4-year disease-free survival (DFS). Forty-eight HNSCC patients treated with CRT underwent ¹⁸F-FLT PET/CT before and during CRT. Median follow-up was 52 months. Primary tumors were automatically delineated and characterized by extracting max and mean SUV, proliferative volume and associated sphericity. Prognostic value for DFS of clinical and imaging features was assessed using Kaplan-Meier survival analysis. In univariate analysis after correction for multiple testing, the per-treatment sphericity (HR=4.2, p=0.02) and SUVmean (HR=4.1, p=0.03) were prognostic factors, whereas none of the pre-treatment variables were significant. Reduction in SUVmax (HR=4, p=0.04) was also a prognostic factor, but not reduction of proliferative tumor volume. The best stratification of patients for DFS was achieved by combining per-treatment SUVmean and sphericity (HR=6.7, p<0.001). High sphericity combined with low mean ¹⁸F-FLT uptake during treatment were associated with better DFS. These results suggest the potential prognostic value of tumor characterization from ¹⁸F-FLT PET in HNSCC that may be further explored in larger cohorts.
- Open Access
- 8 July 2017
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 44 (S1) , 4-16
Quantification, improvement, and harmonization of small lesion detection with state-of-the-art PET
In recent years, there have been multiple advances in positron emission tomography/computed tomography (PET/CT) that improve cancer imaging. The present generation of PET/CT scanners introduces new hardware, software, and acquisition methods. This review describes these new developments, which include time-of-flight (TOF), point-spread-function (PSF), maximum-a-posteriori (MAP) based reconstruction, smaller voxels, respiratory gating, metal artefact reduction, and administration of quadratic weight-dependent 18F–fluorodeoxyglucose (FDG) activity. Also, hardware developments such as continuous bed motion (CBM), (digital) solid-state photodetectors and combined PET and magnetic resonance (MR) systems are explained. These novel techniques have a significant impact on cancer imaging, as they result in better image quality, improved small lesion detectability, and more accurate quantification of radiopharmaceutical uptake. This influences cancer diagnosis and staging, as well as therapy response monitoring and radiotherapy planning. Finally, the possible impact of these developments on the European Association of Nuclear Medicine (EANM) guidelines and EANM Research Ltd. (EARL) accreditation for FDG-PET/CT tumor imaging is discussed.
- 8 July 2017
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 44 (S1) , 4-16
Open AccessQuantification, improvement, and harmonization of small lesion detection with state-of-the-art PET
In recent years, there have been multiple advances in positron emission tomography/computed tomography (PET/CT) that improve cancer imaging. The present generation of PET/CT scanners introduces new hardware, software, and acquisition methods. This review describes these new developments, which include time-of-flight (TOF), point-spread-function (PSF), maximum-a-posteriori (MAP) based reconstruction, smaller voxels, respiratory gating, metal artefact reduction, and administration of quadratic weight-dependent 18F–fluorodeoxyglucose (FDG) activity. Also, hardware developments such as continuous bed motion (CBM), (digital) solid-state photodetectors and combined PET and magnetic resonance (MR) systems are explained. These novel techniques have a significant impact on cancer imaging, as they result in better image quality, improved small lesion detectability, and more accurate quantification of radiopharmaceutical uptake. This influences cancer diagnosis and staging, as well as therapy response monitoring and radiotherapy planning. Finally, the possible impact of these developments on the European Association of Nuclear Medicine (EANM) guidelines and EANM Research Ltd. (EARL) accreditation for FDG-PET/CT tumor imaging is discussed.
- Open Access
- 7 December 2016
- Published by Springer Nature in EJNMMI Physics
- Vol. 3 (1) , 1-14
A 3D-printed anatomical pancreas and kidney phantom for optimizing SPECT/CT reconstruction settings in beta cell imaging using 111In-exendin
Quantitative single photon emission computed tomography (SPECT) is challenging, especially for pancreatic beta cell imaging with 111In-exendin due to high uptake in the kidneys versus much lower uptake in the nearby pancreas. Therefore, we designed a three-dimensionally (3D) printed phantom representing the pancreas and kidneys to mimic the human situation in beta cell imaging. The phantom was used to assess the effect of different reconstruction settings on the quantification of the pancreas uptake for two different, commercially available software packages. 3D-printed, hollow pancreas and kidney compartments were inserted into the National Electrical Manufacturers Association (NEMA) NU2 image quality phantom casing. These organs and the background compartment were filled with activities simulating relatively high and low pancreatic 111In-exendin uptake for, respectively, healthy humans and type 1 diabetes patients. Images were reconstructed using Siemens Flash 3D and Hermes Hybrid Recon, with varying numbers of iterations and subsets and corrections. Images were visually assessed on homogeneity and artefacts, and quantitatively by the pancreas-to-kidney activity concentration ratio. Phantom images were similar to clinical images and showed comparable artefacts. All corrections were required to clearly visualize the pancreas. Increased numbers of subsets and iterations improved the quantitative performance but decreased homogeneity both in the pancreas and the background. Based on the phantom analyses, the Hybrid Recon reconstruction with 6 iterations and 16 subsets was found to be most suitable for clinical use. This work strongly contributed to quantification of pancreatic 111In-exendin uptake. It showed how clinical images of 111In-exendin can be interpreted and enabled selection of the most appropriate protocol for clinical use.
- 7 December 2016
- Published by Springer Nature in EJNMMI Physics
- Vol. 3 (1) , 1-14
Open AccessA 3D-printed anatomical pancreas and kidney phantom for optimizing SPECT/CT reconstruction settings in beta cell imaging using 111In-exendin
Quantitative single photon emission computed tomography (SPECT) is challenging, especially for pancreatic beta cell imaging with 111In-exendin due to high uptake in the kidneys versus much lower uptake in the nearby pancreas. Therefore, we designed a three-dimensionally (3D) printed phantom representing the pancreas and kidneys to mimic the human situation in beta cell imaging. The phantom was used to assess the effect of different reconstruction settings on the quantification of the pancreas uptake for two different, commercially available software packages. 3D-printed, hollow pancreas and kidney compartments were inserted into the National Electrical Manufacturers Association (NEMA) NU2 image quality phantom casing. These organs and the background compartment were filled with activities simulating relatively high and low pancreatic 111In-exendin uptake for, respectively, healthy humans and type 1 diabetes patients. Images were reconstructed using Siemens Flash 3D and Hermes Hybrid Recon, with varying numbers of iterations and subsets and corrections. Images were visually assessed on homogeneity and artefacts, and quantitatively by the pancreas-to-kidney activity concentration ratio. Phantom images were similar to clinical images and showed comparable artefacts. All corrections were required to clearly visualize the pancreas. Increased numbers of subsets and iterations improved the quantitative performance but decreased homogeneity both in the pancreas and the background. Based on the phantom analyses, the Hybrid Recon reconstruction with 6 iterations and 16 subsets was found to be most suitable for clinical use. This work strongly contributed to quantification of pancreatic 111In-exendin uptake. It showed how clinical images of 111In-exendin can be interpreted and enabled selection of the most appropriate protocol for clinical use.
- Open Access
- 24 February 2015
- Published by Springer Nature in EJNMMI Physics
- Vol. 2 (1) , 5
Tumor and red bone marrow dosimetry: comparison of methods for prospective treatment planning in pretargeted radioimmunotherapy
Red bone marrow (RBM) toxicity is dose-limiting in (pretargeted) radioimmunotherapy (RIT). Previous blood-based and two-dimensional (2D) image-based methods have failed to show a clear dose-response relationship. We developed a three-dimensional (3D) image-based RBM dosimetry approach using the Monte Carlo-based 3D radiobiological dosimetry (3D-RD) software and determined its additional value for predicting RBM toxicity. RBM doses were calculated for 13 colorectal cancer patients after pretargeted RIT with the two-step administration of an anti-CEA × anti-HSG bispecific monoclonal antibody and a 177Lu-labeled di-HSG-peptide. 3D-RD RBM dosimetry was based on the lumbar vertebrae, delineated on single photon emission computed tomography (SPECT) scans acquired directly, 3, 24, and 72 h after 177Lu administration. RBM doses were correlated to hematologic effects, according to NCI-CTC v3 and compared with conventional 2D cranium-based and blood-based dosimetry results. Tumor doses were calculated with 3D-RD, which has not been possible with 2D dosimetry. Tumor-to-RBM dose ratios were calculated and compared for 177Lu-based pretargeted RIT and simulated pretargeted RIT with 90Y. 3D-RD RBM doses of all seven patients who developed thrombocytopenia were higher (range 0.43 to 0.97 Gy) than that of the six patients without thrombocytopenia (range 0.12 to 0.39 Gy), except in one patient (0.47 Gy) without thrombocytopenia but with grade 2 leucopenia. Blood and 2D image-based RBM doses for patients with grade 1 to 2 thrombocytopenia were in the same range as in patients without thrombocytopenia (0.14 to 0.29 and 0.11 to 0.26 Gy, respectively). Blood-based RBM doses for two grade 3 to 4 patients were higher (0.66 and 0.51 Gy, respectively) than the others, and the cranium-based dose of only the grade 4 patient was higher (0.34 Gy). Tumor-to-RBM dose ratios would increase by 25% on average when treating with 90Y instead of 177Lu. 3D dosimetry identifies patients at risk of developing any grade of RBM toxicity more accurately than blood- or 2D image-based methods. It has the added value to enable calculation of tumor-to-RBM dose ratios.
- 24 February 2015
- Published by Springer Nature in EJNMMI Physics
- Vol. 2 (1) , 5
Open AccessTumor and red bone marrow dosimetry: comparison of methods for prospective treatment planning in pretargeted radioimmunotherapy
Red bone marrow (RBM) toxicity is dose-limiting in (pretargeted) radioimmunotherapy (RIT). Previous blood-based and two-dimensional (2D) image-based methods have failed to show a clear dose-response relationship. We developed a three-dimensional (3D) image-based RBM dosimetry approach using the Monte Carlo-based 3D radiobiological dosimetry (3D-RD) software and determined its additional value for predicting RBM toxicity. RBM doses were calculated for 13 colorectal cancer patients after pretargeted RIT with the two-step administration of an anti-CEA × anti-HSG bispecific monoclonal antibody and a 177Lu-labeled di-HSG-peptide. 3D-RD RBM dosimetry was based on the lumbar vertebrae, delineated on single photon emission computed tomography (SPECT) scans acquired directly, 3, 24, and 72 h after 177Lu administration. RBM doses were correlated to hematologic effects, according to NCI-CTC v3 and compared with conventional 2D cranium-based and blood-based dosimetry results. Tumor doses were calculated with 3D-RD, which has not been possible with 2D dosimetry. Tumor-to-RBM dose ratios were calculated and compared for 177Lu-based pretargeted RIT and simulated pretargeted RIT with 90Y. 3D-RD RBM doses of all seven patients who developed thrombocytopenia were higher (range 0.43 to 0.97 Gy) than that of the six patients without thrombocytopenia (range 0.12 to 0.39 Gy), except in one patient (0.47 Gy) without thrombocytopenia but with grade 2 leucopenia. Blood and 2D image-based RBM doses for patients with grade 1 to 2 thrombocytopenia were in the same range as in patients without thrombocytopenia (0.14 to 0.29 and 0.11 to 0.26 Gy, respectively). Blood-based RBM doses for two grade 3 to 4 patients were higher (0.66 and 0.51 Gy, respectively) than the others, and the cranium-based dose of only the grade 4 patient was higher (0.34 Gy). Tumor-to-RBM dose ratios would increase by 25% on average when treating with 90Y instead of 177Lu. 3D dosimetry identifies patients at risk of developing any grade of RBM toxicity more accurately than blood- or 2D image-based methods. It has the added value to enable calculation of tumor-to-RBM dose ratios.