Two-Dimensional Observation of Copper Atoms After Forced Extinction of Vacuum Arcs by Laser-Induced Fluorescence
- 17 July 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 48 (8) , 2777-2789
Abstract
The distribution and dissipation of neutral atoms are crucial for understanding the dielectric recovery process after interrupting direct current (DC) vacuum arcs. This article aims to investigate the dissipation of copper atoms after a forced extinction of the vacuum arc experimentally, adopting the plane laser-induced fluorescence method. The change in the 2-D distribution of copper atoms with time is presented. The results show that the magnetic fields, the axial magnetic field (AMF), and the transverse magnetic field (TMF) have a limited effect on the initial density of copper atoms. For both the AMF and the TMF, the copper atom densities at current zero (CZ) vary in the range (6-8) x10¹⁷ m⁻³ when 3-kA vacuum arcs are forced to 0 in 0.2 ms. Contrary to the TMF case, in the AMF case, the evaporation on the anode after the CZ results in long-existing atoms near it. Consequently, the atom density of the TMF decays faster than that of the AMF, which indicates that a vacuum interrupter with the TMF contacts has a better performance when interrupting a DC load. The difference between the two magnetic fields originates from the arc control patterns. Namely, the AMF tends to keep vacuum arcs in a stable mode, which is unfavorable for a DC interruption; on the contrary, the TMF drives the vacuum arcs to move at high velocities resulting in faster dissipation of copper atoms after the CZ. In addition, the composition proportion of CuCr contacts has a limited effect on the diffusion of copper atoms when a low-vacuum arc is interrupted.Keywords
Funding Information
- National Natural Science Foundation of China (51937009, 51807147)
- Natural Science Basic Research Plan in Shaanxi Province of China (2019JM-158)
- ABB university collaboration project
This publication has 49 references indexed in Scilit:
- Anode phenomena in arc discharges: a reviewPlasma Sources Science and Technology, 2011
- Modeling of breakdown during the post-arc phase of a vacuum circuit breakerPlasma Sources Science and Technology, 2010
- A DC Hybrid Circuit Breaker With Ultra-Fast Contact Opening and Integrated Gate-Commutated Thyristors (IGCTs)IEEE Transactions on Power Delivery, 2006
- History of vacuum circuit breakers and recent developments in JapanIEEE Transactions on Dielectrics and Electrical Insulation, 2006
- Recovery of breakdown strength of a vacuum interrupter after extinction of high currentsIEEE Transactions on Dielectrics and Electrical Insulation, 2002
- DC current interruption in HVDC SF/sub 6/ gas MRTB by means of self-excited oscillation superimpositionIEEE Transactions on Power Delivery, 2001
- Cathode spots of electric arcsJournal of Physics D: Applied Physics, 2001
- Collisional transfer and neutral copper vapour density during a diffuse vacuum arcJournal of Physics D: Applied Physics, 1990
- Measurement of high copper vapour densities by laser-induced fluorescenceJournal of Physics D: Applied Physics, 1988
- Measurement of the neutral vapour density decay following the extinction of a high-current vacuum arc between copper electrodesJournal of Physics D: Applied Physics, 1975