Eliminating the non-Gaussian spectral response of X-ray absorbers for transition-edge sensors
- 6 November 2017
- journal article
- conference paper
- Published by AIP Publishing in Applied Physics Letters
- Vol. 111 (19)
Abstract
Transition-edge sensors (TESs) as microcalorimeters for high-energy-resolution X-ray spectroscopy are often fabricated with an absorber made of materials with high Z (for X-ray stopping power) and low heat capacity (for high resolving power). Bismuth represents one of the most compelling options. TESs with evaporated bismuth absorbers have shown spectra with undesirable and unexplained low-energy tails. We have developed TESs with electroplated bismuth absorbers over a gold layer that are not afflicted by this problem and that retain the other positive aspects of this material. To better understand these phenomena, we have studied a series of TESs with gold, gold/evaporated bismuth, and gold/electroplated bismuth absorbers, fabricated on the same die with identical thermal coupling. We show that the bismuth morphology is linked to the spectral response of X-ray TES microcalorimeters.Keywords
All Related Versions
Funding Information
- DOC | National Institute of Standards and Technology
- U.S. Department of Energy (DE-AC0206CH11357)
This publication has 24 references indexed in Scilit:
- A practical superconducting-microcalorimeter X-ray spectrometer for beamline and laboratory scienceReview of Scientific Instruments, 2017
- Development of Thick Electroplated Bismuth Absorbers for Large Collection Area Hard X-ray Transition Edge SensorsIEEE Transactions on Applied Superconductivity, 2017
- Absolute Energy Calibration of X-ray TESs with 0.04 eV Uncertainty at 6.4 keV in a Hadron-Beam EnvironmentJournal of Low Temperature Physics, 2016
- The Practice of Pulse ProcessingJournal of Low Temperature Physics, 2015
- Optimizing detector geometry for trace element mapping by X-ray fluorescenceUltramicroscopy, 2015
- Performance of TES X-ray Microcalorimeters with a Novel Absorber DesignJournal of Low Temperature Physics, 2008
- Optimized transition-edge x-ray microcalorimeter with 2.4eV energy resolution at 5.9keVApplied Physics Letters, 2005
- and x-ray emission lines of the transition metalsPhysical Review A, 1997
- Thermalization of X-rays in evaporated tin and bismuth films used as the absorbing materials in X-ray calorimetersJournal of Low Temperature Physics, 1993
- Specific Heat of Antimony and Bismuth between 0.03 and 0.8 KPhysical Review B, 1970