DYDaikang Yan

Daikang Yan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Daikang Yan has a total of 87 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design and characterization of W-band and D-band calibration sources for the AliCPT-1 experiment

    by Xu-Fang Li, Cong-Zhan Liu, Ai-Mei Zhang, Zheng-Wei Li, Xue-Feng Lu, Zhong-Xue Xin, Guo-Feng Wang, Yong-Ping Li, Yong-Jie Zhang, Shi-Bo Shu, et al.

    Ali Cosmic Microwave Background Polarization Telescope (AliCPT-1) is the first Chinese cosmic microwave background experiment aiming to make sensitive polarization maps of the potential B-mode signal from inflationary gravitational waves. The telescope was deployed on the Tibet Ali site at 5250 m above sea level in early 2025. Before and after each observation season, the instrument performance must be carefully calibrated, including the far field beam performance, far sidelobe, spectral response, polarization angle, and cross-polar beam response. To characterize these optical performances, several calibrators have been developed. We developed a W-band source and a D-band source for the AliCPT-1 telescope's beam characterizations. We present the design and performance of the two calibration sources.

  • Design and characterization of W-band and D-band calibration sources for the AliCPT-1 experiment

    by Xu-Fang Li, Cong-Zhan Liu, Ai-Mei Zhang, Zheng-Wei Li, Xue-Feng Lu, Zhong-Xue Xin, Guo-Feng Wang, Yong-Ping Li, Yong-Jie Zhang, Shi-Bo Shu, et al.

    Ali Cosmic Microwave Background Polarization Telescope (AliCPT-1) is the first Chinese cosmic microwave background experiment aiming to make sensitive polarization maps of the potential B-mode signal from inflationary gravitational waves. The telescope was deployed on the Tibet Ali site at 5250 m above sea level in early 2025. Before and after each observation season, the instrument performance must be carefully calibrated, including the far field beam performance, far sidelobe, spectral response, polarization angle, and cross-polar beam response. To characterize these optical performances, several calibrators have been developed. We developed a W-band source and a D-band source for the AliCPT-1 telescope’s beam characterizations. We present the design and performance of the two calibration sources.


  • Open Access

    Extracting the electronic structure of light elements in bulk materials through a Compton scattering method in the readily accessible hard x-ray regime

    by Veenavee Nipunika Kothalawala, Tejas Guruswamy, Orlando Quaranta, Umeshkumar Manibhai Patel, Lisa Gades, Keith Taddei, Andrey Yakovenko, Meiying Zheng, Kelsey Morgan, Joel Weber, et al.

    Our Compton profile measurements of Ti and TiH2 using readily available hard X-ray radiation at 27.5 keV, detected by both a Hitachi Vortex silicon-drift detector and a high-resolution superconducting transition-edge sensor array, are found to be in excellent accord with state-of-the-art density functional theory based calculations. The spherically averaged difference between the Compton profiles of TiH2 and Ti is well described by an inverted parabola, supporting an itinerant behavior of the electron gas screening the protons in the Ti matrix. Our experimental approach, validated by two different detectors, extends the applicability of Compton scattering technique to the readily accessible hard x-ray regime (below 30 keV). Our study suggests possibilities for experiments at low-flux bending magnet synchrotron beamlines and paves the way for the development of tabletop Compton experiments with x-ray tubes.


  • A configurable ultra-low noise current source for transition-edge sensor characterization

    by N. Li, G. Liao, D. Yan, Y. Xu, Y. Zhang, Z. Liu, S. Yuan, H. Gao, Y. Li, Y. Gu, et al.

    Transition-edge sensors (TESs) are sensitive devices for detecting photons from millimeter radiation to γ rays. Their photon counting efficiency and collecting area benefit from large-array multiplexing scheme, and therefore the development of multiplexing readout system has been an important topic in this field. Among the many multiplex techniques, time-division multiplexing (TDM) superconducting quantum interference device (SQUID) has been used most widely for TES readout. In this work, we design a Configurable Ultra-Low Noise Current Source (CLCS) for TES characterization and as a part of a whole TDM-TES bias control system. The CLCS is based on the feedback structure of ultra-low noise instrumentation amplifiers and low-noise, high-resolution (20 bits) digital-to-analog converter (DAC). CLCS has an ultra-high resolution of 10 nA in the 0 to 5 mA current output range, and can perform current-voltage (IV) sweep and bias-step tests to measure key TES parameters on board. The feedback structure of the CLCS also avoids the issue of impedance mismatch.

  • Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV

    by Daikang Yan, Joel C. Weber, Tejas Guruswamy, Kelsey M. Morgan, Galen C. O’nEil, Abigail L. Wessels, Douglas A. Bennett, Christine G. Pappas, John A. Mates, Johnathon D. Gard, et al.


  • Transition-Edge Sensor Optimization for Hard X-ray Applications

    by Daikang Yan, Joel C. Weber, Kelsey M. Morgan, Abigail L. Wessels, Douglas A. Bennett, Christine G. Pappas, John A. Mates, Johnathon D. Gard, Daniel T. Becker, Joseph W. Fowler, et al.

    Arrays of superconducting transition-edge sensor (TES) microcalorimeters are attractive for some X-ray experiments where the combination of higher collection efficiency than crystal spectrometers and much better energy resolution than semiconductor detectors is enabling. For hard X-ray (>2 keV) applications, a TES is often integrated with an extra absorber to extend its dynamic range, quantum efficiency and collecting area. For >100 keV applications, millimeter size absorbers have been manually attached to TES pixels after fabrication. At lower energies, the absorber size needs to be much smaller, because a large heat capacity degrades energy resolution. In that case, the absorber is directly electroplated or evaporated on the TES during the fabrication process. In this work, we present TES microcalorimeters optimized for the intermediate hard X-ray energy region (20 keV ∼ 100 keV) that have thick absorbers directly deposited during the TES fabrication process. This microcalorimeter is designed to measure high-resolution muonic atom transition X-ray spectra as a method to study quantum electrodynamics (QED) effects. The absorber is comprised of evaporated gold and electroplated bismuth layers and is designed to optimize dynamic range, collecting efficiency, and energy resolution in the 20 keV to 45 keV energy range. A prototype with pure gold absorbers has been fabricated and characterized, in order to obtain a first experimental reference in the detector development process.


  • A two-dimensional resistor network model for transition-edge sensors with normal metal features

    by Daikang Yan, Lisa M Gades, Tejas Guruswamy, Antonino Miceli, Umeshkumar M Patel, Orlando Quaranta

    Transition-edge sensors (TESs) can be used in high-resolution photon detection, exploiting the steep slope of the resistance in the superconducting-to-normal transition edge. Normal metal bars on the TES film are commonly used to engineer its transition shape, namely the dependence of resistance on temperature and current. This problem has been studied in one-dimension, however until now, there have been no predictive models of the influence of two-dimensional (2D) normal metal features on the TES transition shape. In this work, we approach this problem by treating the TES as a 2D network of resistors, the values of which are based on the two-fluid model. We present a study of the behavior of devices with different 2D geometric features. Our 2D network model is capable of predicting how typical TES geometry parameters, such as number of bars, bar spacing, and overall dimensions, influence device behavior and thus is a powerful tool to guide the engineering of new TES devices.


  • Open Access

    Modelling a Transition-Edge Sensor X-Ray Microcalorimeter Linear Array for Compton Profile Measurements and Energy Dispersive Diffraction

    by Daikang Yan, Lisa M. Gades, Tejas Guruswamy, Umeshkumar M. Patel, Orlando Quaranta, Antonino Miceli

    Transition-edge sensors (TES) are a type of superconducting detector that offers high energy resolution based on their sharp resistance-temperature feature in the superconducting-to-normal transition. TES X-ray microcalorimeters have typically been designed and used for spectroscopic applications. In this work, we present a design optimization for a TES X-ray microcalorimeter array for high-energy scattering and diffraction measurements. In particular, Compton scattering provides information about the electron momentum distribution, while energy dispersive diffraction provides structural information about dense engineering materials. Compton scattering and energy dispersive diffraction experiments must be conducted in the very hard X-ray regime (~100 keV), demanding a high X-ray stopping power in the detector; therefore, an absorber with a large heat capacity is needed in conjunction with the TES. In addition, both applications would benefit from an array composed of parallel strips. We present a design for a TES X-ray microcalorimeter optimized for such applications. In particular, we model the longitudinal position dependence due to the finite thermal diffusion time in the absorber.


  • Eliminating the non-Gaussian spectral response of X-ray absorbers for transition-edge sensors

    by Daikang Yan, Ralu Divan, Lisa M. Gades, Peter Kenesei, Timothy J. Madden, Antonino Miceli, Jun-Sang Park, Umeshkumar M. Patel, Orlando Quaranta, Hemant Sharma, et al.

    Transition-edge sensors (TESs) as microcalorimeters for high-energy-resolution X-ray spectroscopy are often fabricated with an absorber made of materials with high Z (for X-ray stopping power) and low heat capacity (for high resolving power). Bismuth represents one of the most compelling options. TESs with evaporated bismuth absorbers have shown spectra with undesirable and unexplained low-energy tails. We have developed TESs with electroplated bismuth absorbers over a gold layer that are not afflicted by this problem and that retain the other positive aspects of this material. To better understand these phenomena, we have studied a series of TESs with gold, gold/evaporated bismuth, and gold/electroplated bismuth absorbers, fabricated on the same die with identical thermal coupling. We show that the bismuth morphology is linked to the spectral response of X-ray TES microcalorimeters.