Performance Study of a Large Monolithic LYSO PET Detector With Accurate Photon DOI Using Retroreflector Layers
- 12 April 2017
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 1 (3) , 229-237
Abstract
Clinical and organ-dedicated PET systems typically require a high efficiency imposing the use of thick scintillators, normally through crystal arrays. To provide depth of interaction (DOI) information, two or more layers are sometimes mounted in the staggered or phoswich approach. In this paper, we are proposing an alternative using thick and large monolithic crystals. We have tested two surface treatments for a 50 mm × 50 mm × 20 mm LYSO block. We provide data in this paper as close as 5 mm to the lateral walls. We left those walls black painted and the exit face coupled to the photosensor (12 × 12 SiPM array) polished. The entrance face was: 1) black painted or 2) coupled to a retroreflector (RR) layer. These configurations keep a good DOI linearity and, on average, reached 4 mm DOI resolution, measured as the full width at half of the maximum. Approaches using RR layers return constant and good energy resolutions nearing 12%, compared to a range of 15%-16% in the case of totally black painted blocks. The best result concerning the detector spatial resolution was obtained when one of the smallest RR was used (120 um corner cube size), being 1.7 mm at the entrance crystal layer and 0.7 mm in the layer closest to the photosensor. These values worsen at least 30% for the black treatment case.Keywords
Funding Information
- EU FP7 Program (603002)
- Spanish Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica (TEC 2013-48036-C3-1-R)
- Valencian Local Government (PROMETEOII/2013/010, ISIC 2011/013)
- CSIC through the Ramon y Cajal modality
This publication has 24 references indexed in Scilit:
- The MINDView brain PET detector, feasibility study based on SiPM arraysNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- Recent developments in time-of-flight PETEJNMMI Physics, 2016
- Analysis of the Statistical Moments of the Scintillation Light Distribution With dSiPMsIEEE Transactions on Nuclear Science, 2015
- Retroreflector arrays for better light collection efficiency of γ-ray imaging detectors with continuous scintillation crystals without DOI misestimationJournal of Instrumentation, 2014
- Advances in multimodal neuroimaging: Hybrid MR–PET and MR–PET–EEG at 3T and 9.4TJournal of Magnetic Resonance, 2013
- Combining Surface Treatments With Shallow Slots to Improve the Spatial Resolution Performance of Continuous, Thick LYSO Detectors for PETIEEE Transactions on Nuclear Science, 2013
- Evaluation of light extraction from PET detector modules using gamma equivalent UV excitation2012
- A practical method for depth of interaction determination in monolithic scintillator PET detectorsPhysics in Medicine & Biology, 2011
- A micro-machined retro-reflector for improving light yield in ultra-high-resolution gamma camerasPhysics in Medicine & Biology, 2009
- The use of retro-reflective tape for improving spatial resolution of scintillation detectorsIEEE Transactions on Nuclear Science, 2002