Feasibility study of a proton CT system based on 4D-tracking and residual energy determination via time-of-flight
- 20 April 2022
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (9) , 095005
Abstract
Objective. For dose calculations in ion beam therapy, it is vital to accurately determine the relative stopping power (RSP) distribution within the treatment volume. A suitable imaging modality to achieve the required RSP accuracy is proton computed tomography (pCT), which usually uses a tracking system and a separate residual energy (or range) detector to directly measure the RSP distribution. This work investigates the potential of a novel pCT system based on a single detector technology, namely low gain avalanche detectors (LGADs). LGADs are fast 4D-tracking detectors, which can be used to simultaneously measure the particle position and time with precise timing and spatial resolution. In contrast to standard pCT systems, the residual energy is determined via a time-of-flight (TOF) measurement between different 4D-tracking stations. Approach. To show the potential of using 4D-tracking for proton imaging, we studied and optimized the design parameters for a realistic TOF-pCT system using Monte Carlo simulations. We calculated the RSP accuracy and RSP resolution inside the inserts of the CTP404 phantom and compared the results to a simulation of an ideal pCT system. Main results. After introducing a dedicated calibration procedure for the TOF calorimeter, RSP accuracies less than 0.6% could be achieved. We also identified the design parameters with the strongest impact on the RSP resolution and proposed a strategy to further improve the image quality. Significance. This comprehensive study of the most important design aspects for a novel TOF-pCT system could help guide future hardware developments and, once implemented, improve the quality of treatment planning in ion beam therapy.Keywords
All Related Versions
Funding Information
- Österreichische Forschungsförderungsgesellschaft (869878)
This publication has 34 references indexed in Scilit:
- Software platform for simulation of a prototype proton CT scannerMedical Physics, 2017
- Improved dose calculation accuracy for low energy brachytherapy by optimizing dual energy CT imaging protocols for noise reduction using sinogram affirmed iterative reconstructionZeitschrift für Medizinische Physik, 2016
- Novel scintillation detector design and performance for proton radiography and computed tomographyMedical Physics, 2016
- Comparison of proton therapy treatment planning for head tumors with a pencil beam algorithm on dual and single energy CT imagesMedical Physics, 2016
- A proton Computed Tomography based medical imaging systemJournal of Instrumentation, 2014
- Filtered backprojection proton CT reconstruction along most likely pathsMedical Physics, 2013
- Development of a head scanner for proton CTNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2013
- Calculation of water equivalent thickness of materials of arbitrary density, elemental composition and thickness in proton beam irradiationPhysics in Medicine & Biology, 2009
- A maximum likelihood proton path formalism for application in proton computed tomographyMedical Physics, 2008
- The management of imaging dose during image‐guided radiotherapy: Report of the AAPM Task Group 75Medical Physics, 2007