Felix Ulrich-Pur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Felix Ulrich-Pur has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Albert Hirtl
Institute for Atomic and Sub-Atomic Physics, TU Wien, Vienna, Austria
7 shared publications Thomas Bergauer
Institute of High Energy Physics, Austrian Academy of Sciences, Nikolsdorfergasse 18, Wien, 1050, AUSTRIA
5 shared publications- Thomas Bergauer
Institut für Hochenergiephysik
4 shared publications Alexander Burker
Atominstitut
3 shared publicationsChristian Irmler
Institute of High Energy Physics (HEPHY)
3 shared publicationsClaus Schmitzer
EBG MedAustron GmbH
3 shared publications
Latest Publications
- Open Access
- 1 July 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (07) , C07022
Development of a double-sided LGAD prototype from single-sided sensors: design, characterization, and proof of principle
This work presents the development and experimental validation of a novel thin (active layer thickness of 85 μm) double-sided strip Low-Gain Avalanche Detector (LGAD) prototype. We demonstrate a post-fabrication segmentation process where a standard single-sided LGAD sensor is micromachined to enable dual-sided signal extraction. Characterization using a dedicated front-end electronics system confirms strong spatial and temporal correlations between the junction and ohmic sides. The results validate that this architecture preserves the excellent timing performance of LGADs while providing a scalable solution for high-precision tracking in material-sensitive applications. By applying this procedure in conjunction with additional sensor thinning, a total sensor thickness below 50 μm can be achieved. To our knowledge, this represents the first implementation of a thin double-sided LGAD.
- 1 July 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (07) , C07022
Open AccessDevelopment of a double-sided LGAD prototype from single-sided sensors: design, characterization, and proof of principle
This work presents the development and experimental validation of a novel thin (active layer thickness of 85 μm) double-sided strip Low-Gain Avalanche Detector (LGAD) prototype. We demonstrate a post-fabrication segmentation process where a standard single-sided LGAD sensor is micromachined to enable dual-sided signal extraction. Characterization using a dedicated front-end electronics system confirms strong spatial and temporal correlations between the junction and ohmic sides. The results validate that this architecture preserves the excellent timing performance of LGADs while providing a scalable solution for high-precision tracking in material-sensitive applications. By applying this procedure in conjunction with additional sensor thinning, a total sensor thickness below 50 μm can be achieved. To our knowledge, this represents the first implementation of a thin double-sided LGAD.
- Open Access
- 19 November 2025
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 28 (11)
Double multiturn injection scheme for generating mixed helium and carbon ion beams at medical synchrotron facilities
The low relative charge-to-mass ratio offset of 0.065% between fully ionized helium-4 and carbon-12 ions enables simultaneous acceleration in hadron therapy synchrotrons. At the same energy per mass, helium ions exhibit a stopping range approximately 3 times greater than carbon ions. They can therefore be exploited for online range verification downstream of the patient during carbon ion beam irradiation. One possibility for creating this mixed beam is accelerating the two ion species sequentially through the LINAC and subsequently “mixing” them at injection energy in the synchrotron with a double multiturn injection scheme. This work reports the first successful generation, acceleration, and extraction of a mixed helium and carbon ion beam using this double multiturn injection scheme, which was achieved at the MedAustron therapy accelerator in Austria. A description of the double multiturn injection scheme, particle tracking simulations, and details on the implementation at the MedAustron accelerator facility are presented and discussed. Finally, measurements of the mixed beam at delivery in the irradiation room using a radiochromic film and a low-gain avalanche diode detector are presented.
- 19 November 2025
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 28 (11)
Open AccessDouble multiturn injection scheme for generating mixed helium and carbon ion beams at medical synchrotron facilities
The low relative charge-to-mass ratio offset of 0.065% between fully ionized helium-4 and carbon-12 ions enables simultaneous acceleration in hadron therapy synchrotrons. At the same energy per mass, helium ions exhibit a stopping range approximately 3 times greater than carbon ions. They can therefore be exploited for online range verification downstream of the patient during carbon ion beam irradiation. One possibility for creating this mixed beam is accelerating the two ion species sequentially through the LINAC and subsequently “mixing” them at injection energy in the synchrotron with a double multiturn injection scheme. This work reports the first successful generation, acceleration, and extraction of a mixed helium and carbon ion beam using this double multiturn injection scheme, which was achieved at the MedAustron therapy accelerator in Austria. A description of the double multiturn injection scheme, particle tracking simulations, and details on the implementation at the MedAustron accelerator facility are presented and discussed. Finally, measurements of the mixed beam at delivery in the irradiation room using a radiochromic film and a low-gain avalanche diode detector are presented.
- Open Access
- 1 August 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (08) , C08007
LGAD technology for heavy ion detection and radiation damage diagnostics in diamond
We present the application of LGAD technology for time-of-flight measurements of heavy ions and for precise diagnostics of radiation damage in diamond sensors. The polycrystalline CVD (pcCVD) diamond sensor used in this work was irradiated with heavy ion beams at GSI, Darmstadt, Germany during several experimental campaigns and subsequently investigated at MedAustron, Wiener Neustadt, Austria. To mitigate radiation-induced performance degradation, we propose a dedicated amplification system originally developed for LGAD sensors, which significantly extends the operational lifetime of diamond detectors. For precise sensor diagnostics, we employed strip LGAD sensors — commonly used for minimum ionizing particle (MIP) detection — and demonstrated their excellent performance for heavy ion (He/C) detection, achieving timing resolutions below 40 ps.
- 1 August 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (08) , C08007
Open AccessLGAD technology for heavy ion detection and radiation damage diagnostics in diamond
We present the application of LGAD technology for time-of-flight measurements of heavy ions and for precise diagnostics of radiation damage in diamond sensors. The polycrystalline CVD (pcCVD) diamond sensor used in this work was irradiated with heavy ion beams at GSI, Darmstadt, Germany during several experimental campaigns and subsequently investigated at MedAustron, Wiener Neustadt, Austria. To mitigate radiation-induced performance degradation, we propose a dedicated amplification system originally developed for LGAD sensors, which significantly extends the operational lifetime of diamond detectors. For precise sensor diagnostics, we employed strip LGAD sensors — commonly used for minimum ionizing particle (MIP) detection — and demonstrated their excellent performance for heavy ion (He/C) detection, achieving timing resolutions below 40 ps.
- Open Access
- 28 March 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (7) , 075031
First experimental time-of-flight-based proton radiography using low gain avalanche diodes
Objective. Ion computed tomography (iCT) is an imaging modality for the direct determination of the relative stopping power (RSP) distribution within a patient’s body. Usually, this is done by estimating the path and energy loss of ions traversing the scanned volume utilising a tracking system and a separate residual energy detector. This study, on the other hand, introduces the first experimental study of a novel iCT approach based on time-of-flight (TOF) measurements, the so-called Sandwich TOF-iCT concept, which in contrast to any other iCT systems, does not require a residual energy detector for the RSP determination. Approach. A small Sandwich TOF-iCT demonstrator was built based on low gain avalanche diodes (LGADs), which are 4D-tracking detectors that allow to simultaneously measure the particle position and time-of-arrival with a precision better than 100 μ m and 100 ps, respectively. Using this demonstrator, the material and energy-dependent TOF was measured for several homogeneous PMMA slabs in order to calibrate the acquired TOF against the corresponding water equivalent thickness (WET). With this calibration, two proton radiographs (pRads) of a small aluminium stair phantom were recorded at MedAustron using 83 MeV and 100.4 MeV protons. Main results. Due to the simplified WET calibration models used in this very first experimental study of this novel approach, the difference between the measured and theoretical WET ranged between 37.09% and 51.12%. Nevertheless, the first TOF-based pRad was successfully recorded showing that LGADs are suitable detector candidates for Sandwich TOF-iCT. Significance. While the system parameters and WET estimation algorithms require further optimization, this work was an important first step to realize Sandwich TOF-iCT. Due to its compact and cost-efficient design, Sandwich TOF-iCT has the potential to make iCT more feasible and attractive for clinical application, which, eventually, could enhance the treatment planning quality.
- 28 March 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (7) , 075031
Open AccessFirst experimental time-of-flight-based proton radiography using low gain avalanche diodes
Objective. Ion computed tomography (iCT) is an imaging modality for the direct determination of the relative stopping power (RSP) distribution within a patient’s body. Usually, this is done by estimating the path and energy loss of ions traversing the scanned volume utilising a tracking system and a separate residual energy detector. This study, on the other hand, introduces the first experimental study of a novel iCT approach based on time-of-flight (TOF) measurements, the so-called Sandwich TOF-iCT concept, which in contrast to any other iCT systems, does not require a residual energy detector for the RSP determination. Approach. A small Sandwich TOF-iCT demonstrator was built based on low gain avalanche diodes (LGADs), which are 4D-tracking detectors that allow to simultaneously measure the particle position and time-of-arrival with a precision better than 100 μ m and 100 ps, respectively. Using this demonstrator, the material and energy-dependent TOF was measured for several homogeneous PMMA slabs in order to calibrate the acquired TOF against the corresponding water equivalent thickness (WET). With this calibration, two proton radiographs (pRads) of a small aluminium stair phantom were recorded at MedAustron using 83 MeV and 100.4 MeV protons. Main results. Due to the simplified WET calibration models used in this very first experimental study of this novel approach, the difference between the measured and theoretical WET ranged between 37.09% and 51.12%. Nevertheless, the first TOF-based pRad was successfully recorded showing that LGADs are suitable detector candidates for Sandwich TOF-iCT. Significance. While the system parameters and WET estimation algorithms require further optimization, this work was an important first step to realize Sandwich TOF-iCT. Due to its compact and cost-efficient design, Sandwich TOF-iCT has the potential to make iCT more feasible and attractive for clinical application, which, eventually, could enhance the treatment planning quality.
- Open Access
First experimental time-of-flight-based proton radiography using low gain avalanche diodes
Ion computed tomography (iCT) is an imaging modality for the direct determination of the relative stopping power (RSP) distribution within a patient's body. Usually, this is done by estimating the path and energy loss of ions traversing the scanned volume via a tracking system and a separate residual energy detector. This study, on the other hand, introduces the first experimental study of a novel iCT approach based on time-of-flight (TOF) measurements, the so-called Sandwich TOF-iCT concept, which in contrast to any other iCT system, does not require a residual energy detector for the RSP determination. A small TOF-iCT demonstrator was built based on low gain avalanche diodes (LGAD), which are 4D-tracking detectors that allow to simultaneously measure the particle position and time-of-arrival with a precision better than 100um and 100ps, respectively. Using this demonstrator, the material and energy-dependent TOF was measured for several homogeneous PMMA slabs in order to calibrate the acquired TOF against the corresponding water equivalent thickness (WET). With this calibration, two proton radiographs (pRad) of a small aluminium stair phantom were recorded at MedAustron using 83 and 100.4MeV protons. Due to the simplified WET calibration models used in this very first experimental study of this novel approach, the difference between the measured and theoretical WET ranged between 37.09 and 51.12%. Nevertheless, the first TOF-based pRad was successfully recorded showing that LGADs are suitable detector candidates for TOF-iCT. While the system parameters and WET estimation algorithms require further optimization, this work was an important first step to realize Sandwich TOF-iCT. Due to its compact and cost-efficient design, Sandwich TOF-iCT has the potential to make iCT more feasible and attractive for clinical application, which, eventually, could enhance the treatment planning quality.
Open AccessFirst experimental time-of-flight-based proton radiography using low gain avalanche diodes
Ion computed tomography (iCT) is an imaging modality for the direct determination of the relative stopping power (RSP) distribution within a patient's body. Usually, this is done by estimating the path and energy loss of ions traversing the scanned volume via a tracking system and a separate residual energy detector. This study, on the other hand, introduces the first experimental study of a novel iCT approach based on time-of-flight (TOF) measurements, the so-called Sandwich TOF-iCT concept, which in contrast to any other iCT system, does not require a residual energy detector for the RSP determination. A small TOF-iCT demonstrator was built based on low gain avalanche diodes (LGAD), which are 4D-tracking detectors that allow to simultaneously measure the particle position and time-of-arrival with a precision better than 100um and 100ps, respectively. Using this demonstrator, the material and energy-dependent TOF was measured for several homogeneous PMMA slabs in order to calibrate the acquired TOF against the corresponding water equivalent thickness (WET). With this calibration, two proton radiographs (pRad) of a small aluminium stair phantom were recorded at MedAustron using 83 and 100.4MeV protons. Due to the simplified WET calibration models used in this very first experimental study of this novel approach, the difference between the measured and theoretical WET ranged between 37.09 and 51.12%. Nevertheless, the first TOF-based pRad was successfully recorded showing that LGADs are suitable detector candidates for TOF-iCT. While the system parameters and WET estimation algorithms require further optimization, this work was an important first step to realize Sandwich TOF-iCT. Due to its compact and cost-efficient design, Sandwich TOF-iCT has the potential to make iCT more feasible and attractive for clinical application, which, eventually, could enhance the treatment planning quality.
- 20 April 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (9) , 095005
Feasibility study of a proton CT system based on 4D-tracking and residual energy determination via time-of-flight
Objective. For dose calculations in ion beam therapy, it is vital to accurately determine the relative stopping power (RSP) distribution within the treatment volume. A suitable imaging modality to achieve the required RSP accuracy is proton computed tomography (pCT), which usually uses a tracking system and a separate residual energy (or range) detector to directly measure the RSP distribution. This work investigates the potential of a novel pCT system based on a single detector technology, namely low gain avalanche detectors (LGADs). LGADs are fast 4D-tracking detectors, which can be used to simultaneously measure the particle position and time with precise timing and spatial resolution. In contrast to standard pCT systems, the residual energy is determined via a time-of-flight (TOF) measurement between different 4D-tracking stations. Approach. To show the potential of using 4D-tracking for proton imaging, we studied and optimized the design parameters for a realistic TOF-pCT system using Monte Carlo simulations. We calculated the RSP accuracy and RSP resolution inside the inserts of the CTP404 phantom and compared the results to a simulation of an ideal pCT system. Main results. After introducing a dedicated calibration procedure for the TOF calorimeter, RSP accuracies less than 0.6% could be achieved. We also identified the design parameters with the strongest impact on the RSP resolution and proposed a strategy to further improve the image quality. Significance. This comprehensive study of the most important design aspects for a novel TOF-pCT system could help guide future hardware developments and, once implemented, improve the quality of treatment planning in ion beam therapy.
- 20 April 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (9) , 095005
Feasibility study of a proton CT system based on 4D-tracking and residual energy determination via time-of-flight
Objective. For dose calculations in ion beam therapy, it is vital to accurately determine the relative stopping power (RSP) distribution within the treatment volume. A suitable imaging modality to achieve the required RSP accuracy is proton computed tomography (pCT), which usually uses a tracking system and a separate residual energy (or range) detector to directly measure the RSP distribution. This work investigates the potential of a novel pCT system based on a single detector technology, namely low gain avalanche detectors (LGADs). LGADs are fast 4D-tracking detectors, which can be used to simultaneously measure the particle position and time with precise timing and spatial resolution. In contrast to standard pCT systems, the residual energy is determined via a time-of-flight (TOF) measurement between different 4D-tracking stations. Approach. To show the potential of using 4D-tracking for proton imaging, we studied and optimized the design parameters for a realistic TOF-pCT system using Monte Carlo simulations. We calculated the RSP accuracy and RSP resolution inside the inserts of the CTP404 phantom and compared the results to a simulation of an ideal pCT system. Main results. After introducing a dedicated calibration procedure for the TOF calorimeter, RSP accuracies less than 0.6% could be achieved. We also identified the design parameters with the strongest impact on the RSP resolution and proposed a strategy to further improve the image quality. Significance. This comprehensive study of the most important design aspects for a novel TOF-pCT system could help guide future hardware developments and, once implemented, improve the quality of treatment planning in ion beam therapy.
- Open Access
Commissioning of low particle flux for proton beams at MedAustron
MedAustron is a synchrotron-based particle therapy centre located in Wiener Neustadt, Austria. It features three irradiation rooms for particle therapy, where proton beams with energies up to 252.7 MeV and carbon ions of up to 402.8 MeV/u are available for cancer treatment. In addition to the treatment rooms, MedAustron features a unique beamline exclusively for non-clinical research (NCR). This research beamline is also commissioned for proton energies up to 800 MeV, while available carbon ion energies correspond to the ones available in the clinical treatment rooms. Based on the requirements for particle therapy, all irradiation rooms offer particle rates of up to 10^9 particles/s for protons and 10^7 particles/s for carbon ions. However, for research purposes, lower particle fluxes are required and were therefore commissioned for the NCR beamline. Three particle flux settings with particle rates ranging from ~2.4x10^3 particles/s to ~5.2x10^6 particles/s were established for seven proton energies below 252.7 MeV. In addition to the particle rate, the spot sizes and beam energies were measured for these settings. Furthermore, three low flux settings for 800 MeV protons with particle rates ranging from ~2x10^3 particles/s to ~1.3x10^6 particles/s were commissioned. Since the commissioned low flux settings are in a regime well below the limits of the available standard beam diagnostics, setting up the beam under these new operational conditions entirely relied on the use of external detectors. Furthermore, a beam position measurement based alignment without using the standard beam profile monitors was performed for 800 MeV protons.
Open AccessCommissioning of low particle flux for proton beams at MedAustron
MedAustron is a synchrotron-based particle therapy centre located in Wiener Neustadt, Austria. It features three irradiation rooms for particle therapy, where proton beams with energies up to 252.7 MeV and carbon ions of up to 402.8 MeV/u are available for cancer treatment. In addition to the treatment rooms, MedAustron features a unique beamline exclusively for non-clinical research (NCR). This research beamline is also commissioned for proton energies up to 800 MeV, while available carbon ion energies correspond to the ones available in the clinical treatment rooms. Based on the requirements for particle therapy, all irradiation rooms offer particle rates of up to 10^9 particles/s for protons and 10^7 particles/s for carbon ions. However, for research purposes, lower particle fluxes are required and were therefore commissioned for the NCR beamline. Three particle flux settings with particle rates ranging from ~2.4x10^3 particles/s to ~5.2x10^6 particles/s were established for seven proton energies below 252.7 MeV. In addition to the particle rate, the spot sizes and beam energies were measured for these settings. Furthermore, three low flux settings for 800 MeV protons with particle rates ranging from ~2x10^3 particles/s to ~1.3x10^6 particles/s were commissioned. Since the commissioned low flux settings are in a regime well below the limits of the available standard beam diagnostics, setting up the beam under these new operational conditions entirely relied on the use of external detectors. Furthermore, a beam position measurement based alignment without using the standard beam profile monitors was performed for 800 MeV protons.
- Open Access
Single particle tracking uncertainties in ion imaging
An extensive comparison of the path uncertainty in single particle tracking systems for ion imaging was carried out based on Monte Carlo simulations. The spatial resolution as function of system parameters such as geometry, detector properties and the energy of proton and helium beams was investigated to serve as a guideline for hardware developments. Primary particle paths were sampled within a water volume and compared to the most likely path estimate obtained from detector measurements, yielding a depth-dependent uncertainty envelope. The maximum uncertainty along this curve was converted to a conservative estimate of the minimal radiographic pixel spacing for a single set of parameter values. Simulations with various parameter settings were analysed to obtain an overview of the reachable pixel spacing as function of system parameters. The results were used to determine intervals of detector material budget and position resolution that yield a pixel spacing small enough for clinical dose calculation. To ensure a pixel spacing below 2 mm, the material budget of a detector should remain below 0.25 % for a position resolution of 200 $\mathrm{\mu m}$ or below 0.75 % for a resolution of 10 $\mathrm{\mu m}$. Using protons, a sub-millimetre pixel size could not be achieved for a phantom size of 300 mm or at a large clearance. With helium ions, a sub-millimetre pixel spacing could be achieved even for a large phantom size and clearance, provided the position resolution was less than 100 $\mathrm{\mu m}$ and material budget was below 0.75 %.Open AccessSingle particle tracking uncertainties in ion imaging
An extensive comparison of the path uncertainty in single particle tracking systems for ion imaging was carried out based on Monte Carlo simulations. The spatial resolution as function of system parameters such as geometry, detector properties and the energy of proton and helium beams was investigated to serve as a guideline for hardware developments. Primary particle paths were sampled within a water volume and compared to the most likely path estimate obtained from detector measurements, yielding a depth-dependent uncertainty envelope. The maximum uncertainty along this curve was converted to a conservative estimate of the minimal radiographic pixel spacing for a single set of parameter values. Simulations with various parameter settings were analysed to obtain an overview of the reachable pixel spacing as function of system parameters. The results were used to determine intervals of detector material budget and position resolution that yield a pixel spacing small enough for clinical dose calculation. To ensure a pixel spacing below 2 mm, the material budget of a detector should remain below 0.25 % for a position resolution of 200 $\mathrm{\mu m}$ or below 0.75 % for a resolution of 10 $\mathrm{\mu m}$. Using protons, a sub-millimetre pixel size could not be achieved for a phantom size of 300 mm or at a large clearance. With helium ions, a sub-millimetre pixel spacing could be achieved even for a large phantom size and clearance, provided the position resolution was less than 100 $\mathrm{\mu m}$ and material budget was below 0.75 %.