Endovascular adhesive repair using N-butyl cyanoacrylate for spontaneous dissecting aneurysms of the celiac and hepatic arteries: technique and long-term outcomes
Authors:
Open Access
- 4 September 2026
- journal article
- research article
- Published by Springer Nature in CVIR Endovascular
- Vol. 9 (1) , 113
Abstract
Purpose: To describe false lumen embolization with an endovascular adhesive repair concept, in which N-butyl cyanoacrylate is injected with the intention of promoting reapposition of the dissected layers while preserving the parent-artery. Materials and methods: Three men aged 50, 55, and 68 years with spontaneous dissecting aneurysms of the celiac axis (two patients) or the right hepatic artery (one patient, with dissection extending from the common hepatic artery) were treated; one patient had segmental arterial mediolysis; in another, the gastroduodenal collateral pathway had been surgically interrupted by prior pancreaticoduodenectomy. Indications were aneurysm enlargement with persistent pain, progressive aneurysm enlargement, and concern for rupture during planned endoscopic treatment. A microcatheter was navigated into the false lumen under digital subtraction angiography, and a 33% N-butyl cyanoacrylate–iodized oil mixture was injected to embolize the false lumen and appose the intimal flap. In two patients, a silicone balloon catheter was used to limit N-butyl cyanoacrylate overflow into the true lumen; it was introduced through a separate femoral access in Case 1 and through the same guiding sheath as the microcatheter in Case 2. Technical and clinical success, parent-artery patency, complications, and recurrence were assessed. Results: Evident inflow into the false lumen disappeared in all cases, with all parent-arteries preserved. There was no rupture, unintended non-target embolization, or catheter adhesion. Follow-up showed no recurrence, and patency was verified during clinically indicated vascular studies at 10.5, 6, and 4 years; in two patients the repaired segment again served as a catheterization route. Conclusion: False lumen embolization with an endovascular adhesive repair concept was technically successful with parent-artery preservation in three highly selected patients, and patency was confirmed at 10.5, 6, and 4 years after treatment. Further investigation is required to determine the safety, reproducibility, and appropriate indications of this technique. Level of evidence: Level 4, Case Series.Keywords
This publication has 12 references indexed in Scilit:
- Technical considerations of endovascular management of true visceral artery aneurysmsCVIR Endovascular, 2023
- Segmental arterial mediolysis (SAM): Systematic review and analysis of 143 casesVascular Medicine, 2019
- Natural history of spontaneous isolated celiac artery dissection after conservative treatmentJournal of Vascular Surgery, 2018
- Natural course and outcomes of spontaneous isolated celiac artery dissection according to morphological findings on computed tomography angiographyMedicine, 2018
- Clinical outcome of endovascular therapeutic occlusion of the celiac arteryJournal of Vascular Surgery, 2007
- Endovascular Treatment of Pseudoaneurysm of the Common Hepatic Artery with Intra-aneurysmal Glue (N-Butyl 2-Cyanoacrylate) EmbolizationCardioVascular and Interventional Radiology, 2007
- Late Complications of Gelatin-Resorcin-Formalin Glue in the Repair of Acute Type A Aortic DissectionThe Annals of Thoracic Surgery, 2007
- Treatment of a Hepatic Artery Aneurysm by Endovascular Stent-GraftingCardioVascular and Interventional Radiology, 2007
- Embolization of visceral pseudoaneurysms with platinum coils and N -butyl cyanoacrylateAbdominal Radiology, 2003
- Glue aortoplasty repair of aortic dissection after coronary angioplastyThe Annals of Thoracic Surgery, 2001