Hideki Ishimaru
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hideki Ishimaru has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
Taiga Oka
9 shared publicationsRyo Toya
Department of Radiological Sciences, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan
6 shared publicationsShuto Miyamura
6 shared publicationsMaki Hirao
5 shared publications- Masataka Uetani
Department of Radiology, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan
5 shared publications - Reiko Ideguchi
Department of Radioisotope Medicine, Atomic Bomb Disease Institute, Nagasaki University, Nagasaki, Japan
5 shared publications
Latest Publications
- 7 September 2026
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 37 (12)
Retrieval of a Prematurely Detached Coil by Intentional Thrombus Formation within the Microcatheter
- 7 September 2026
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 37 (12)
Retrieval of a Prematurely Detached Coil by Intentional Thrombus Formation within the Microcatheter
- Open Access
- 4 September 2026
- Published by Springer Nature in CVIR Endovascular
- Vol. 9 (1) , 113
Endovascular adhesive repair using N-butyl cyanoacrylate for spontaneous dissecting aneurysms of the celiac and hepatic arteries: technique and long-term outcomes
Purpose: To describe false lumen embolization with an endovascular adhesive repair concept, in which N-butyl cyanoacrylate is injected with the intention of promoting reapposition of the dissected layers while preserving the parent-artery. Materials and methods: Three men aged 50, 55, and 68 years with spontaneous dissecting aneurysms of the celiac axis (two patients) or the right hepatic artery (one patient, with dissection extending from the common hepatic artery) were treated; one patient had segmental arterial mediolysis; in another, the gastroduodenal collateral pathway had been surgically interrupted by prior pancreaticoduodenectomy. Indications were aneurysm enlargement with persistent pain, progressive aneurysm enlargement, and concern for rupture during planned endoscopic treatment. A microcatheter was navigated into the false lumen under digital subtraction angiography, and a 33% N-butyl cyanoacrylate–iodized oil mixture was injected to embolize the false lumen and appose the intimal flap. In two patients, a silicone balloon catheter was used to limit N-butyl cyanoacrylate overflow into the true lumen; it was introduced through a separate femoral access in Case 1 and through the same guiding sheath as the microcatheter in Case 2. Technical and clinical success, parent-artery patency, complications, and recurrence were assessed. Results: Evident inflow into the false lumen disappeared in all cases, with all parent-arteries preserved. There was no rupture, unintended non-target embolization, or catheter adhesion. Follow-up showed no recurrence, and patency was verified during clinically indicated vascular studies at 10.5, 6, and 4 years; in two patients the repaired segment again served as a catheterization route. Conclusion: False lumen embolization with an endovascular adhesive repair concept was technically successful with parent-artery preservation in three highly selected patients, and patency was confirmed at 10.5, 6, and 4 years after treatment. Further investigation is required to determine the safety, reproducibility, and appropriate indications of this technique. Level of evidence: Level 4, Case Series.
- 4 September 2026
- Published by Springer Nature in CVIR Endovascular
- Vol. 9 (1) , 113
Open AccessEndovascular adhesive repair using N-butyl cyanoacrylate for spontaneous dissecting aneurysms of the celiac and hepatic arteries: technique and long-term outcomes
Purpose: To describe false lumen embolization with an endovascular adhesive repair concept, in which N-butyl cyanoacrylate is injected with the intention of promoting reapposition of the dissected layers while preserving the parent-artery. Materials and methods: Three men aged 50, 55, and 68 years with spontaneous dissecting aneurysms of the celiac axis (two patients) or the right hepatic artery (one patient, with dissection extending from the common hepatic artery) were treated; one patient had segmental arterial mediolysis; in another, the gastroduodenal collateral pathway had been surgically interrupted by prior pancreaticoduodenectomy. Indications were aneurysm enlargement with persistent pain, progressive aneurysm enlargement, and concern for rupture during planned endoscopic treatment. A microcatheter was navigated into the false lumen under digital subtraction angiography, and a 33% N-butyl cyanoacrylate–iodized oil mixture was injected to embolize the false lumen and appose the intimal flap. In two patients, a silicone balloon catheter was used to limit N-butyl cyanoacrylate overflow into the true lumen; it was introduced through a separate femoral access in Case 1 and through the same guiding sheath as the microcatheter in Case 2. Technical and clinical success, parent-artery patency, complications, and recurrence were assessed. Results: Evident inflow into the false lumen disappeared in all cases, with all parent-arteries preserved. There was no rupture, unintended non-target embolization, or catheter adhesion. Follow-up showed no recurrence, and patency was verified during clinically indicated vascular studies at 10.5, 6, and 4 years; in two patients the repaired segment again served as a catheterization route. Conclusion: False lumen embolization with an endovascular adhesive repair concept was technically successful with parent-artery preservation in three highly selected patients, and patency was confirmed at 10.5, 6, and 4 years after treatment. Further investigation is required to determine the safety, reproducibility, and appropriate indications of this technique. Level of evidence: Level 4, Case Series.
- 18 April 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 64 (2) , 504-512
Hypointensity on Carotid Plaque MRI and Its Relationship to Calcification: Histopathologic Validation With Quantitative Susceptibility Mapping
Background: On conventional carotid plaque MRI, calcification is commonly defined as a region that is hypointense across multiple contrast weightings. However, iron‐containing components such as hemosiderin may exhibit similar signal characteristics, raising concerns regarding substrate specificity. Purpose: To evaluate whether quantitative susceptibility mapping (QSM) can distinguish hemosiderin from calcification in carotid atherosclerotic plaques using ex vivo MRI with direct histopathologic correlation. Study Type: Ex vivo specimen study. Specimen: Twenty‐four carotid endarterectomy specimens obtained between October 2017 and August 2021. Field Strength/Sequence: 3T MRI including spin‐echo T1‐weighted, spin‐echo T2‐weighted, time‐of‐flight–equivalent gradient‐echo (FLASH) imaging, and multi‐echo FLASH–based QSM reconstruction. Assessment: Histologic sections were stained with hematoxylin–eosin, von Kossa (calcification), and Berlin blue (hemosiderin). With histopathologic findings as reference, two radiologists defined corresponding regions of interest on MRI for substrate‐level signal characterization. Contrast‐to‐noise ratios (CNR) were measured on conventional sequences, and relative susceptibility values (rSV) were measured on QSM. Statistical Test: Group comparisons were performed using the Wilcoxon rank‐sum test. A two‐sided p < 0.05 was considered statistically significant. Results: Seventy‐nine matched cross‐sections yielded 41 calcifications and 25 hemosiderin deposits, including 16 sections with both components. On T1‐, T2‐, and FLASH imaging, CNR values did not differ significantly between calcification and hemosiderin ( p = 0.12, p = 0.096, and p = 0.67, respectively), with substantial signal overlap. On QSM, hemosiderin exhibited positive rSVs (mean ± SD: 506.8 ± 320.5 ppb), whereas calcification exhibited negative rSVs (−440.5 ± 296.3 ppb), without polarity overlap in this dataset and with a significant group difference. Hemosiderin deposition was identified in 25 of 79 matched sections, and calcification and hemosiderin coexisted in 16 sections. Data Conclusions: Hypointensity on conventional carotid plaque MRI may not reliably indicate calcification at the substrate level. QSM enables robust differentiation between diamagnetic calcium and paramagnetic iron with histopathologic validation. Level of Evidence: 2. Technical Efficacy: Stage 2.
- 18 April 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 64 (2) , 504-512
Hypointensity on Carotid Plaque MRI and Its Relationship to Calcification: Histopathologic Validation With Quantitative Susceptibility Mapping
Background: On conventional carotid plaque MRI, calcification is commonly defined as a region that is hypointense across multiple contrast weightings. However, iron‐containing components such as hemosiderin may exhibit similar signal characteristics, raising concerns regarding substrate specificity. Purpose: To evaluate whether quantitative susceptibility mapping (QSM) can distinguish hemosiderin from calcification in carotid atherosclerotic plaques using ex vivo MRI with direct histopathologic correlation. Study Type: Ex vivo specimen study. Specimen: Twenty‐four carotid endarterectomy specimens obtained between October 2017 and August 2021. Field Strength/Sequence: 3T MRI including spin‐echo T1‐weighted, spin‐echo T2‐weighted, time‐of‐flight–equivalent gradient‐echo (FLASH) imaging, and multi‐echo FLASH–based QSM reconstruction. Assessment: Histologic sections were stained with hematoxylin–eosin, von Kossa (calcification), and Berlin blue (hemosiderin). With histopathologic findings as reference, two radiologists defined corresponding regions of interest on MRI for substrate‐level signal characterization. Contrast‐to‐noise ratios (CNR) were measured on conventional sequences, and relative susceptibility values (rSV) were measured on QSM. Statistical Test: Group comparisons were performed using the Wilcoxon rank‐sum test. A two‐sided p < 0.05 was considered statistically significant. Results: Seventy‐nine matched cross‐sections yielded 41 calcifications and 25 hemosiderin deposits, including 16 sections with both components. On T1‐, T2‐, and FLASH imaging, CNR values did not differ significantly between calcification and hemosiderin ( p = 0.12, p = 0.096, and p = 0.67, respectively), with substantial signal overlap. On QSM, hemosiderin exhibited positive rSVs (mean ± SD: 506.8 ± 320.5 ppb), whereas calcification exhibited negative rSVs (−440.5 ± 296.3 ppb), without polarity overlap in this dataset and with a significant group difference. Hemosiderin deposition was identified in 25 of 79 matched sections, and calcification and hemosiderin coexisted in 16 sections. Data Conclusions: Hypointensity on conventional carotid plaque MRI may not reliably indicate calcification at the substrate level. QSM enables robust differentiation between diamagnetic calcium and paramagnetic iron with histopathologic validation. Level of Evidence: 2. Technical Efficacy: Stage 2.
- 8 April 2026
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 47 (11) , 2710-2718
Histologically Validated Ex Vivo Characterization of Intraplaque Hemorrhage and Lipid Components Using Quantitative Susceptibility Mapping
Accurate characterization of carotid plaque components is essential for stroke risk assessment. Intraplaque hemorrhage (IPH) is a well-established marker of plaque vulnerability, whereas lipid-rich necrotic cores (LRNCs) often show overlapping signal characteristics with IPH on conventional MRI. The purpose of this study was to compare quantitative susceptibility mapping (QSM) with conventional MRI in differentiating IPH and lipid components in carotid plaques using ex vivo histologic validation. Twenty-four carotid plaque specimens obtained by en bloc excision during carotid endarterectomy between October 2017 and August 2021 were examined. All specimens underwent ex vivo MRI at 3T, including T1WI, T2WI, and TOF-equivalent FLASH, as well as QSM reconstructed from multi-echo FLASH phase data. After MRI, specimens were serially sectioned and stained using H&E and immunohistochemical techniques. ROIs corresponding to histologically confirmed IPH and lipid components were delineated on MRI by consensus of two radiologists. On conventional MRI, signal intensities were measured in corresponding histologic regions, and contrast-to-noise ratios (CNRs) were calculated relative to surrounding agarose gel. On QSM, absolute magnetic susceptibility values were measured in the same regions. The difference between plaque tissue and the surrounding agarose gel was defined as the relative susceptibility value (rSV), which was used for statistical analysis. CNRs and rSVs among plaque components were compared using the Kruskal-Wallis test, followed by the Steel-Dwass test for pairwise comparisons. Seventy-nine matched cross-sectional slices were analyzed, yielding 24 IPH, 61 LRNCs, and 13 foam-cell aggregates (FAs). No significant difference in CNR was observed between IPH and LRNC on T1WI or FLASH. Histopathologic analysis demonstrated that many LRNCs exhibited erythrocyte-derived remnants consistent with prior hemorrhagic events. FAs showed lower CNRs than IPH on T1WI and FLASH (P < .05). On T2WI, IPH showed lower CNRs than LRNCs or FAs (P < .05). On QSM, IPH demonstrated higher rSVs than LRNCs or FAs (P < .01). Histologic validation demonstrates that many LRNCs contain erythrocyte remnants, which may contribute to their overlapping signal characteristics with IPH on conventional MRI. QSM captures erythrocyte-derived susceptibility effects within plaques and provides complementary susceptibility-based information not available from conventional MRI.
- 8 April 2026
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 47 (11) , 2710-2718
Histologically Validated Ex Vivo Characterization of Intraplaque Hemorrhage and Lipid Components Using Quantitative Susceptibility Mapping
Accurate characterization of carotid plaque components is essential for stroke risk assessment. Intraplaque hemorrhage (IPH) is a well-established marker of plaque vulnerability, whereas lipid-rich necrotic cores (LRNCs) often show overlapping signal characteristics with IPH on conventional MRI. The purpose of this study was to compare quantitative susceptibility mapping (QSM) with conventional MRI in differentiating IPH and lipid components in carotid plaques using ex vivo histologic validation. Twenty-four carotid plaque specimens obtained by en bloc excision during carotid endarterectomy between October 2017 and August 2021 were examined. All specimens underwent ex vivo MRI at 3T, including T1WI, T2WI, and TOF-equivalent FLASH, as well as QSM reconstructed from multi-echo FLASH phase data. After MRI, specimens were serially sectioned and stained using H&E and immunohistochemical techniques. ROIs corresponding to histologically confirmed IPH and lipid components were delineated on MRI by consensus of two radiologists. On conventional MRI, signal intensities were measured in corresponding histologic regions, and contrast-to-noise ratios (CNRs) were calculated relative to surrounding agarose gel. On QSM, absolute magnetic susceptibility values were measured in the same regions. The difference between plaque tissue and the surrounding agarose gel was defined as the relative susceptibility value (rSV), which was used for statistical analysis. CNRs and rSVs among plaque components were compared using the Kruskal-Wallis test, followed by the Steel-Dwass test for pairwise comparisons. Seventy-nine matched cross-sectional slices were analyzed, yielding 24 IPH, 61 LRNCs, and 13 foam-cell aggregates (FAs). No significant difference in CNR was observed between IPH and LRNC on T1WI or FLASH. Histopathologic analysis demonstrated that many LRNCs exhibited erythrocyte-derived remnants consistent with prior hemorrhagic events. FAs showed lower CNRs than IPH on T1WI and FLASH (P < .05). On T2WI, IPH showed lower CNRs than LRNCs or FAs (P < .05). On QSM, IPH demonstrated higher rSVs than LRNCs or FAs (P < .01). Histologic validation demonstrates that many LRNCs contain erythrocyte remnants, which may contribute to their overlapping signal characteristics with IPH on conventional MRI. QSM captures erythrocyte-derived susceptibility effects within plaques and provides complementary susceptibility-based information not available from conventional MRI.
- Open Access
- 1 January 2026
- Published by Japan Surgical Society in Surgical Case Reports
- Vol. 12 (1) , cr.26-0077
Hepatic Compartment Syndrome Induced by Subcapsular Hematoma following Percutaneous Transhepatic Gallbladder Drainage: A Case Report
INTRODUCTION: Hepatic compartment syndrome (HCS) is a rare but potentially fatal condition caused by acute elevation of intrahepatic pressure, most often secondary to a subcapsular hematoma. Iatrogenic cases, particularly after percutaneous hepatobiliary interventions, have been only sporadically reported. We describe HCS following percutaneous transhepatic gallbladder drainage (PTGBD) complicated by a subcapsular hepatic hematoma.CASE PRESENTATION: A 49-year-old man underwent PTGBD for acute cholecystitis at the referring hospital. The catheter dislodged, and repeated attempts at re-placement over a guidewire failed, leaving the tip within the hepatic subcapsular space. The following day, he developed worsening abdominal pain, and CT revealed a massive right hepatic subcapsular hematoma. He was urgently transferred to our hospital. Contrast-enhanced CT demonstrated active extravasation, prompting emergency interventional radiology. Hepatic arteriography showed hepatofugal flow in the portal venous system, confirming HCS caused by intraparenchymal hypertension due to subcapsular compression. Decompression was achieved by placing a drain into the hematoma via the original PTGBD tract, followed by selective hepatic arterial embolization. Peak serum aspartate aminotransferase and alanine aminotransferase levels reached 9873 and 7385 U/L, respectively, before gradually declining. The hematoma caused compression of the inferior vena cava, intra-abdominal hypertension, and secondary acute kidney injury with pulmonary edema, requiring temporary renal replacement therapy. The hematoma progressively regressed with restored hepatic perfusion. Renal replacement therapy was discontinued prior to transfer, the drain was removed on day 24, and the patient was transferred for rehabilitation on day 34.CONCLUSIONS: Early recognition of HCS and prompt decompression are essential to prevent irreversible hepatic and multiorgan injury.
- 1 January 2026
- Published by Japan Surgical Society in Surgical Case Reports
- Vol. 12 (1) , cr.26-0077
Open AccessHepatic Compartment Syndrome Induced by Subcapsular Hematoma following Percutaneous Transhepatic Gallbladder Drainage: A Case Report
INTRODUCTION: Hepatic compartment syndrome (HCS) is a rare but potentially fatal condition caused by acute elevation of intrahepatic pressure, most often secondary to a subcapsular hematoma. Iatrogenic cases, particularly after percutaneous hepatobiliary interventions, have been only sporadically reported. We describe HCS following percutaneous transhepatic gallbladder drainage (PTGBD) complicated by a subcapsular hepatic hematoma.CASE PRESENTATION: A 49-year-old man underwent PTGBD for acute cholecystitis at the referring hospital. The catheter dislodged, and repeated attempts at re-placement over a guidewire failed, leaving the tip within the hepatic subcapsular space. The following day, he developed worsening abdominal pain, and CT revealed a massive right hepatic subcapsular hematoma. He was urgently transferred to our hospital. Contrast-enhanced CT demonstrated active extravasation, prompting emergency interventional radiology. Hepatic arteriography showed hepatofugal flow in the portal venous system, confirming HCS caused by intraparenchymal hypertension due to subcapsular compression. Decompression was achieved by placing a drain into the hematoma via the original PTGBD tract, followed by selective hepatic arterial embolization. Peak serum aspartate aminotransferase and alanine aminotransferase levels reached 9873 and 7385 U/L, respectively, before gradually declining. The hematoma caused compression of the inferior vena cava, intra-abdominal hypertension, and secondary acute kidney injury with pulmonary edema, requiring temporary renal replacement therapy. The hematoma progressively regressed with restored hepatic perfusion. Renal replacement therapy was discontinued prior to transfer, the drain was removed on day 24, and the patient was transferred for rehabilitation on day 34.CONCLUSIONS: Early recognition of HCS and prompt decompression are essential to prevent irreversible hepatic and multiorgan injury.
- Open Access
- 13 June 2025
- Published by The Japanese Society of Interventional Radiology in Interventional Radiology
- Vol. 10, e2024-0034
Ruptured Infected Pseudoaneurysms of Bilateral Carotid Artery Treated with Viabahn Stent Graft: A Case Report
A 74-year-old man who had received Bacillus Calmette-Guérin therapy for bladder cancer developed vasovagal syncope. Contrast-enhanced computed tomography showed multiple pseudoaneurysms in the left internal carotid artery, aorta, and right common femoral artery, which were considered to be infected aneurysms. Parent artery occlusion was planned for the left internal carotid artery, but the balloon occlusion test was not possible because of the patient's restlessness; therefore, the patient was treated with a Viabahn stent graft. Approximately 1 month later, another ruptured pseudoaneurysm occurred in the right internal carotid artery, which was also treated with a Viabahn stent graft. The patient did not experience rebleeding or complications such as cerebral infarction. Viabahn may be an effective alternative for the management of carotid artery-infected aneurysms.
- 13 June 2025
- Published by The Japanese Society of Interventional Radiology in Interventional Radiology
- Vol. 10, e2024-0034
Open AccessRuptured Infected Pseudoaneurysms of Bilateral Carotid Artery Treated with Viabahn Stent Graft: A Case Report
A 74-year-old man who had received Bacillus Calmette-Guérin therapy for bladder cancer developed vasovagal syncope. Contrast-enhanced computed tomography showed multiple pseudoaneurysms in the left internal carotid artery, aorta, and right common femoral artery, which were considered to be infected aneurysms. Parent artery occlusion was planned for the left internal carotid artery, but the balloon occlusion test was not possible because of the patient's restlessness; therefore, the patient was treated with a Viabahn stent graft. Approximately 1 month later, another ruptured pseudoaneurysm occurred in the right internal carotid artery, which was also treated with a Viabahn stent graft. The patient did not experience rebleeding or complications such as cerebral infarction. Viabahn may be an effective alternative for the management of carotid artery-infected aneurysms.
- Open Access
- 28 May 2025
- Published by Wiley in IJU Case Reports
- Vol. 8 (4) , 415-418
Percutaneous Transretropubic Needle Prostatic Biopsy Under US and CT Guidance
Introduction: No previous instances of percutaneous transretropubic prostate biopsy have been documented.Case Presentation: A 74‐year‐old male patient with a permanent stoma, who had undergone colectomy for descending colon cancer two decades earlier, reported experiencing dysuria. A screening examination revealed an elevated prostate‐specific antigen level of 120.24 ng/mL. Despite an intact rectum, the patient's anus was severely constricted or blocked, preventing both digital rectal examination and the insertion of a transrectal ultrasound probe. A transabdominal ultrasound‐guided transretropubic prostate biopsy was conducted while monitoring the needle tip position using computed tomography. The subsequent pathological analysis confirmed prostatic adenocarcinoma.Conclusion: This case represents the first reported instance of a percutaneous transretropubic prostate biopsy.
- 28 May 2025
- Published by Wiley in IJU Case Reports
- Vol. 8 (4) , 415-418
Open AccessPercutaneous Transretropubic Needle Prostatic Biopsy Under US and CT Guidance
Introduction: No previous instances of percutaneous transretropubic prostate biopsy have been documented.Case Presentation: A 74‐year‐old male patient with a permanent stoma, who had undergone colectomy for descending colon cancer two decades earlier, reported experiencing dysuria. A screening examination revealed an elevated prostate‐specific antigen level of 120.24 ng/mL. Despite an intact rectum, the patient's anus was severely constricted or blocked, preventing both digital rectal examination and the insertion of a transrectal ultrasound probe. A transabdominal ultrasound‐guided transretropubic prostate biopsy was conducted while monitoring the needle tip position using computed tomography. The subsequent pathological analysis confirmed prostatic adenocarcinoma.Conclusion: This case represents the first reported instance of a percutaneous transretropubic prostate biopsy.
- 16 May 2025
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 36 (9) , 1455-1458.e1
Glue-in-Plug Technique for Spontaneous Shunt-Preserving Disconnection of the Splenic from Portomesenteric Venous Circulation
- 16 May 2025
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 36 (9) , 1455-1458.e1
Glue-in-Plug Technique for Spontaneous Shunt-Preserving Disconnection of the Splenic from Portomesenteric Venous Circulation
- 24 August 2024
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 35 (12) , 1876-1878.e3
Rectal Balloon Distention to Facilitate Retrograde Venous Embolization of an Arteriovenous Malformation
- 24 August 2024
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 35 (12) , 1876-1878.e3
Rectal Balloon Distention to Facilitate Retrograde Venous Embolization of an Arteriovenous Malformation