Evidence for using Monte Carlo calculated wall attenuation and scatter correction factors for three styles of graphite-walled ion chamber
Authors:
- J P McCaffreyJMJ P McCaffrey
- E Mainegra-HingEME Mainegra-Hing
- I KawrakowIKI Kawrakow
- K R ShorttKSK R Shortt
- D W O RogersDRD W O Rogers
- 26 May 2004
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 49 (12) , 2491-2501
Abstract
The basic equation for establishing a 60Co air-kerma standard based on a cavity ionization chamber includes a wall correction term that corrects for the attenuation and scatter of photons in the chamber wall. For over a decade, the validity of the wall correction terms determined by extrapolation methods (K(w)K(cep)) has been strongly challenged by Monte Carlo (MC) calculation methods (K(wall)). Using the linear extrapolation method with experimental data, K(w)K(cep) was determined in this study for three different styles of primary-standard-grade graphite ionization chamber: cylindrical, spherical and plane-parallel. For measurements taken with the same 60Co source, the air-kerma rates for these three chambers, determined using extrapolated K(w)K(cep) values, differed by up to 2%. The MC code 'EGSnrc' was used to calculate the values of K(wall) for these three chambers. Use of the calculated K(wall) values gave air-kerma rates that agreed within 0.3%. The accuracy of this code was affirmed by its reliability in modelling the complex structure of the response curve obtained by rotation of the non-rotationally symmetric plane-parallel chamber. These results demonstrate that the linear extrapolation technique leads to errors in the determination of air-kerma.Keywords
This publication has 17 references indexed in Scilit:
- Results supporting calculated wall correction factors for cavity chambersPhysics in Medicine & Biology, 2003
- Determination of the Kwall correction factor for a cylindrical ionization chamber to measure air-kerma in 60Co gamma beamsPhysics in Medicine & Biology, 2002
- Monte Carlo study of correction factors for Spencer–Attix cavity theory at photon energies at or above 100 keVMedical Physics, 2000
- Accurate condensed history Monte Carlo simulation of electron transport. II. Application to ion chamber response simulationsMedical Physics, 2000
- Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 versionMedical Physics, 2000
- Implications of new correction factors on primary air kerma standards in60Co-beamsPhysics in Medicine & Biology, 1992
- On the technique of extrapolation to obtain wall correction factors for ion chambers irradiated by photon beamsMedical Physics, 1990
- An analytic theory of the point-source nonuniformity correction factor for thick-walled ionisation chambers in photon beamsPhysics in Medicine & Biology, 1990
- Introduction to Radiological Physics and Radiation Dosimetry1986
- A Study of a Graphite Cavity Chamber for Absolute Exposure Measurements of60Co Gamma RaysMetrologia, 1973