EMErnesto Mainegra-Hing

Ernesto Mainegra-Hing

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ernesto Mainegra-Hing has a total of 67 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Adoption of ICRU report 90 recommendations in the Canadian Co-60 air-kerma primary standard

    by E Mainegra-Hing

    The Canadian air-kerma primary standard for60Co beams is updated according to ICRU report 90 (ICRU-90) recommendations. The effect of these recommendations and a more detailed chamber model on the primary standard is investigated. Dosimetric quantities and corrections required for the realization of air kerma are calculated using the EGSnrc Monte Carlo (MC) simulation system. The validity of Spencer–Attix (SA) cavity theory as function of Δ, the secondary particle production threshold energy, is investigated to assess the accuracy of its current selection criterion. Although individual changes in some correction factors are statistically non-negligible, the overall effect amounts to only a 0.04% increase of the standard. The meanrestrictedmass electronic stopping power ratio graphite to air, S¯Δ,g,a decreases from the previous value of 1.0010 to a value of 0.9949. If this value is used with the recommendedWairvalue of 33.97 eV, the effect on the standard is a reduction of 0.613%. When the recommended WairS¯g,a value of 33.72 eV is used instead, the change results in a 0.835% reduction inKair. Using SA cavity theory to obtainKairwith a Δ value of 20 keV, corresponding to the cavity’s mean chord length, reproduces a direct MC calculation at the 0.03% level. Type B uncertainties due to uncertainty in the photon and electron cross sections for the largest correctionsKwallandKcompare estimated to be 0.01% and 0.10%, respectively. No statistically significant effect on the standard is observed due to changes in the correction factors. Fano tests and comparison to single scattering calculations demonstrate EGSnrc’s electron transport algorithm accuracy to be within 0.03% relative to its own cross sections. The latter also validates the criterion for selecting Δ based on the average chord length of the chamber’s cavity. A 0.2% difference in therestrictedstopping power ratio obtained in this work and the value resulting from ICRU-90 recommendations has the potential for affecting standards relying on the absolute value ofWair, thus further investigation is granted. The current update results in a 0.8% decrease of the Canadian60Co air-kerma primary standard with a reduced uncertainty of 0.2%. This change is in excellent agreement with the reported change to the BIPM60Co air-kerma standard.


  • Open Access

    A study of Type B uncertainties associated with the photoelectric effect in low-energy Monte Carlo simulations

    by Christian Valdes-Cortez, Iymad Mansour, Mark J Rivard, Facundo Ballester, Ernesto Mainegra-Hing, Rowan M Thomson, Javier Vijande

    Purpose. To estimate Type B uncertainties in absorbed-dose calculations arising from the different implementations in current state-of-the-art Monte Carlo (MC) codes of low-energy photon cross-sections (Methods. MC simulations are carried out using three codes widely used in the low-energy domain: PENELOPE-2018, EGSnrc, and MCNP. Three dosimetry-relevant quantities are considered: mass energy-absorption coefficients for water, air, graphite, and their respective ratios; absorbed dose; and photon-fluence spectra. The absorbed dose and the photon-fluence spectra are scored in a spherical water phantom of 15 cm radius. Benchmark simulations using similar cross-sections have been performed. The differences observed between these quantities when different cross-sections are considered are taken to be a good estimator for the corresponding Type B uncertainties. Results. A conservative Type B uncertainty for the absorbed dose ( k = 2) of 1.2%–1.7% (k = 2) of about 1.5% (water and air), and 2% (graphite), diminishing in all materials for larger energies and reaching values about 1% (40–50 keV) and 0.5% (50–75 keV). With respect to their ratios, the only significant Type B uncertainties are observed in the case of the water-to-graphite ratio for energies below 30 keV, being about 0.7% ( k = 2). Conclusions. In contrast with the intermediate (about 500 keV) or high (about 1 MeV) energy domains, Type B uncertainties due to the different cross-sections implementation cannot be considered subdominant with respect to Type A uncertainties or even to other sources of Type B uncertainties (tally volume averaging, manufacturing tolerances, etc). Therefore, the values reported here should be accommodated within the uncertainty budget in low-energy photon dosimetry studies.


  • On the impact of ICRU report 90 recommendations on kQ factors for high‐energy photon beams

    by Ernesto Mainegra‐Hing, Bryan R. Muir

    Purpose: To assess the impact of the ICRU report 90 recommendations on the beam‐quality conversion factor, kQ, used for clinical reference dosimetry of megavoltage linac photon beams.Methods: The absorbed dose to water and the absorbed dose to the air in ionization chambers representative of those typically used for linac photon reference dosimetry are calculated at the reference depth in a water phantom using Monte Carlo simulations. Depth‐dose calculations in water are also performed to investigate changes in beam quality specifiers. The calculations are performed in a cobalt‐60 beam and MV photon beams with nominal energy between 6 MV and 25 MV using the EGSnrc simulation toolkit. Inputs to the calculations use stopping‐power data for graphite and water from the original ICRU‐37 report and the new proposed values from the recently published ICRU‐90 report. Calculated kQ factors are compared using the two different recommendations for key dosimetry data and measured kQ factors.Results: Less than about 0.1% effects from ICRU‐90 recommendations on the beam quality specifiers, the photon component of the percentage depth‐dose at 10 cm, %dd(10)x, and the tissue‐phantom ratio at 20 cm and 10 cm, TPR, are observed. Although using different recommendations for key dosimetric data impact water‐to‐air stopping‐power ratios and ion chamber perturbation corrections by up to 0.54% and 0.40%, respectively, we observe little difference (≤0.14%) in calculated kQ factors. This is contradictory to the predictions in ICRU‐90 that suggest differences up to 0.5% in high‐energy photon beams. A slightly better agreement with experimental values is obtained when using ICRU‐90 recommendations.Conclusion: Users of the addendum to the TG‐51 protocol for reference dosimetry of high‐energy photon beams, which recommends Monte Carlo calculated kQ factors, can rest assured that the recommendations of ICRU report 90 on basic data have little impact on this central dosimetric parameter.


  • Open Access

    Validating Fricke dosimetry for the measurement of absorbed dose to water for HDR 192 Ir brachytherapy: a comparison between primary standards of the LCR, Brazil, and the NRC, Canada

    by Camila Salata, Mariano Gazineu David, Carlos Eduardo de Almeida, Islam El Gamal, Claudiu Cojocaru, Ernesto Mainegra-Hing, Malcolm R McEwen

    Two Fricke-based absorbed dose to water standards for HDR Ir-192 dosimetry, developed independently by the LCR in Brazil and the NRC in Canada have been compared. The agreement in the determination of the dose rate from a HDR Ir-192 source at 1 cm in a water phantom was found to be within the k = 1 combined measurement uncertainties of the two standards: D NRC / D LCR = 1.011, standard uncertainty = 2.2%. The dose-based standards also agreed within the uncertainties with the manufacturer’s stated dose rate value, which is traceable to a national standard of air kerma. A number of possible influence quantities were investigated, including the specific method for producing the ferrous-sulphate Fricke solution, the geometry of the holder, and the Monte Carlo code used to determine correction factors. The comparison highlighted the lack of data on the determination of G (Fe 3+ ) in this energy range and the possibilities for further development of the holders used to contain the Fricke solution. The comparison also confirmed the suitability of Fricke dosimetry for Ir-192 primary standard dose rate determinations at therapy dose levels.


  • Open Access

    Hounsfield unit recovery in clinical cone beam CT images of the thorax acquired for image guided radiation therapy

    by Rune Slot Thing, Uffe Bernchou, Ernesto Mainegra-Hing, Olfred Hansen, Carsten Brink

    A comprehensive artefact correction method for clinical cone beam CT (CBCT) images acquired for image guided radiation therapy (IGRT) on a commercial system is presented. The method is demonstrated to reduce artefacts and recover CT-like Hounsfield units (HU) in reconstructed CBCT images of five lung cancer patients. Projection image based artefact corrections of image lag, detector scatter, body scatter and beam hardening are described and applied to CBCT images of five lung cancer patients. Image quality is evaluated through visual appearance of the reconstructed images, HU-correspondence with the planning CT images, and total volume HU error. Artefacts are reduced and CT-like HUs are recovered in the artefact corrected CBCT images. Visual inspection confirms that artefacts are indeed suppressed by the proposed method, and the HU root mean square difference between reconstructed CBCTs and the reference CT images are reduced by 31% when using the artefact corrections compared to the standard clinical CBCT reconstruction. A versatile artefact correction method for clinical CBCT images acquired for IGRT has been developed. HU values are recovered in the corrected CBCT images. The proposed method relies on post processing of clinical projection images, and does not require patient specific optimisation. It is thus a powerful tool for image quality improvement of large numbers of CBCT images.


  • Key comparison BIPM.RI(I)-K3 of the air-kerma standards of the NRC, Canada and the BIPM in medium-energy x-rays

    by D T Burns, C Kessler, E Mainegra-Hing, H Shen, M R McEwen

    A key comparison has been made between the air-kerma standards of the NRC, Canada and the BIPM in the medium-energy x-ray range. The results show the standards to be in agreement at the level of the standard uncertainty of the comparison of 3.3 parts in 103. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  • Open Access

    Monte Carlo reference data sets for imaging research: Executive summary of the report of AAPM Research Committee Task Group 195

    by Ioannis Sechopoulos, Elsayed S. M. Ali, Andreu Badal, Aldo Badano, John M. Boone, Iacovos S. Kyprianou, Ernesto Mainegra‐Hing, Kyle L. McMillan, Michael F. McNitt‐Gray, D. W. O. Rogers, et al.

    The use of Monte Carlo simulations in diagnostic medical imaging research is widespread due to its flexibility and ability to estimate quantities that are challenging to measure empirically. However, any new Monte Carlo simulation code needs to be validated before it can be used reliably. The type and degree of validation required depends on the goals of the research project, but, typically, such validation involves either comparison of simulation results to physical measurements or to previously published results obtained with established Monte Carlo codes. The former is complicated due to nuances of experimental conditions and uncertainty, while the latter is challenging due to typical graphical presentation and lack of simulation details in previous publications. In addition, entering the field of Monte Carlo simulations in general involves a steep learning curve. It is not a simple task to learn how to program and interpret a Monte Carlo simulation, even when using one of the publicly available code packages. This Task Group report provides a common reference for benchmarking Monte Carlo simulations across a range of Monte Carlo codes and simulation scenarios. In the report, all simulation conditions are provided for six different Monte Carlo simulation cases that involve common x‐ray based imaging research areas. The results obtained for the six cases using four publicly available Monte Carlo software packages are included in tabular form. In addition to a full description of all simulation conditions and results, a discussion and comparison of results among the Monte Carlo packages and the lessons learned during the compilation of these results are included. This abridged version of the report includes only an introductory description of the six cases and a brief example of the results of one of the cases. This work provides an investigator the necessary information to benchmark his/her Monte Carlo simulation software against the reference cases included here before performing his/her own novel research. In addition, an investigator entering the field of Monte Carlo simulations can use these descriptions and results as a self‐teaching tool to ensure that he/she is able to perform a specific simulation correctly. Finally, educators can assign these cases as learning projects as part of course objectives or training programs.


  • Open Access

    Implementation of an efficient Monte Carlo calculation for CBCT scatter correction: phantom study

    by Peter G.F. Watson, Ernesto Mainegra‐Hing, Nada Tomic, Jan Seuntjens

    Cone-beam computed tomography (CBCT) images suffer from poor image quality, in a large part due to contamination from scattered X-rays. In this work, a Monte Carlo (MC)-based iterative scatter correction algorithm was implemented on measured phantom data acquired from a clinical on-board CBCT scanner. An efficient EGSnrc user code (egs_cbct) was used to transport photons through an uncorrected CBCT scan of a Catphan 600 phantom. From the simulation output, the contribution from primary and scattered photons was estimated in each projection image. From these estimates, an iterative scatter correction was performed on the raw CBCT projection data. The results of the scatter correction were compared with the default vendor reconstruction. The scatter correction was found to reduce the error in CT number for selected regions of interest, while improving contrast-to-noise ratio (CNR) by 18%. These results demonstrate the performance of the proposed scatter correction algorithm in improving image quality for clinical CBCT images. PACS numbers: 87.10.Rt, 87.57.Q-