Triple function substation and high-efficiency micro booster heat pump for Ultra Low Temperature District Heating
Open Access
- 1 September 2019
- conference paper
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 609 (5) , 052008
Abstract
District-Heating (DH) covers around the 9% of the total heat demand in the EU, with a proven highperformance levels and low operational costs. DH may suffer adaptations in order to maintain competitiveness with individual heating systems. The most important one is the reduction of supply temperatures up to 50°C, emerging the concept of Ultra Low Temperature (ULT) DH. ULT DH allows the transmission and distribution heat losses minimization, since heat losses are proportional to the temperature-gradient between supply line the ambient, increasing overall system performance. Furthermore, enables the integration of low-grade energy sources with low marginal costs, such as solar thermal energy or waste heat from industrial and commercial buildings. This study presents the combination of a novel 3 function-scheme (3FS) substation and a micro booster heat pump for domestic hot water. The novel design of the substation allows different operation modes between the grid and the building according to the temperature level and demand range every moment. Regarding the microbooster, this unit is used directly to lift the temperature of the domestic hot water (DHW), so that risk of legionella is avoided and that the required comfort temperature is reached. Preliminary test for the energy performance of the booster heat pump was measured on serially produced units according to tapping profiles and methodologies of standard EN16147. DHW coefficients of performance of 5.2 and 8.5 were measured for heat source supply temperatures respectively of 25 and 40 °C and return temperatures of 22 and 30 °C. This paper explores the possible operational modes of a 3FS in combination with a Building Integrated Solar Thermal System (BISTS) and a Microbooster heat pump.Keywords
This publication has 7 references indexed in Scilit:
- International review of district heating and coolingEnergy, 2017
- Integrated solar thermal façade system for building retrofitSolar Energy, 2015
- Heat Roadmap Europe: Combining district heating with heat savings to decarbonise the EU energy systemEnergy Policy, 2014
- Renewable-based low-temperature district heating for existing buildings in various stages of refurbishmentEnergy, 2013
- Comparative analyses of seven technologies to facilitate the integration of fluctuating renewable energy sourcesIET Renewable Power Generation, 2009
- A review on buildings energy consumption informationEnergy and Buildings, 2008
- Roof integrated solar heating system with glazed collectorSolar Energy, 2004