Mikel Lumbreras Mugaguren
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mikel Lumbreras Mugaguren has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Roberto Garay-Martinez
Institute of Technology, Faculty of Engineering, University of Deusto, Av. Universidades, 24, 48007 Bilbao, Spain
2 shared publications Víctor Sánchez Zabala
TECNALIA, Building Technologies Division, Astondo Bidea 700, ES-48160 Derio, Spain
2 shared publicationsKasper Korsholm Østergaard
METRO THERM A/S, Rundinsvej 55, 3200, Denmark
1 shared publicationMatteo Caramaschi
METRO THERM A/S, Rundinsvej 55, 3200, Denmark
1 shared publication
Latest Publications
- Open Access
- 1 September 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 609 (5) , 052004
RELaTED, decentralized & renewable Ultra Low Temperature District Heating, concept conversion from traditional district heating
District Heating (DH) are a very efficient system for heating in urban areas and they are considered as key elements for the de-carbonization of the European Cities. High performance levels and low operational energy costs are part of the identity of these heating networks. The reduction of supply-line temperatures allows the possibility to introduce new low-grade and renewable source energy production, reducing dependence on fossil fuel-based energy plants. Moreover, heat-losses in distribution pipelines are also reduced, since the gradient temperature between supply line and ambient temperature is reduced. Operation of decentralized & Ultra Low Temperature (ULT) systems may adapt for the introduction of weather-dependent, distributed heat sources such as solar systems. Furthermore, although very dependent on local availability, waste heat streams from commercial and industrial installations are also considered because of the stability of heat supply all year round, resulting in minimally carbon intensive processes. Regarding building features, the reduced heat load derived from the transition from current buildings to Nearly Zero Energy Buildings (NZEB), RELaTED allows for the novel concept called prosumer, where buildings can deliver energy to the grid from decentralized energy sources installed in the building. In RELaTED, different subsystems are being developed by different industrial partners, to prove their efficiency in 4 real demonstration sites: Tartu (Estonia), Belgrade (Serbia), Vinge (Denmark) and Iurreta (Spain). A 3-FS (3-Function Scheme) DH substation that permits buildings to become prosumers. Two types of solar collectors, one is an all polymeric glazed collector and the second one is an unglazed collector, both as components of Building Integrated Large Solar Thermal Systems (BILSTS) solar loop. Finally, a reversible and high efficiency heat pump for domestic hot water is being developed. In this paper, an approach to ULT concept is studied, including transitory phases of the conversion.
- 1 September 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 609 (5) , 052004
Open AccessRELaTED, decentralized & renewable Ultra Low Temperature District Heating, concept conversion from traditional district heating
District Heating (DH) are a very efficient system for heating in urban areas and they are considered as key elements for the de-carbonization of the European Cities. High performance levels and low operational energy costs are part of the identity of these heating networks. The reduction of supply-line temperatures allows the possibility to introduce new low-grade and renewable source energy production, reducing dependence on fossil fuel-based energy plants. Moreover, heat-losses in distribution pipelines are also reduced, since the gradient temperature between supply line and ambient temperature is reduced. Operation of decentralized & Ultra Low Temperature (ULT) systems may adapt for the introduction of weather-dependent, distributed heat sources such as solar systems. Furthermore, although very dependent on local availability, waste heat streams from commercial and industrial installations are also considered because of the stability of heat supply all year round, resulting in minimally carbon intensive processes. Regarding building features, the reduced heat load derived from the transition from current buildings to Nearly Zero Energy Buildings (NZEB), RELaTED allows for the novel concept called prosumer, where buildings can deliver energy to the grid from decentralized energy sources installed in the building. In RELaTED, different subsystems are being developed by different industrial partners, to prove their efficiency in 4 real demonstration sites: Tartu (Estonia), Belgrade (Serbia), Vinge (Denmark) and Iurreta (Spain). A 3-FS (3-Function Scheme) DH substation that permits buildings to become prosumers. Two types of solar collectors, one is an all polymeric glazed collector and the second one is an unglazed collector, both as components of Building Integrated Large Solar Thermal Systems (BILSTS) solar loop. Finally, a reversible and high efficiency heat pump for domestic hot water is being developed. In this paper, an approach to ULT concept is studied, including transitory phases of the conversion.
- Open Access
- 1 September 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 609 (5) , 052008
Triple function substation and high-efficiency micro booster heat pump for Ultra Low Temperature District Heating
District-Heating (DH) covers around the 9% of the total heat demand in the EU, with a proven highperformance levels and low operational costs. DH may suffer adaptations in order to maintain competitiveness with individual heating systems. The most important one is the reduction of supply temperatures up to 50°C, emerging the concept of Ultra Low Temperature (ULT) DH. ULT DH allows the transmission and distribution heat losses minimization, since heat losses are proportional to the temperature-gradient between supply line the ambient, increasing overall system performance. Furthermore, enables the integration of low-grade energy sources with low marginal costs, such as solar thermal energy or waste heat from industrial and commercial buildings. This study presents the combination of a novel 3 function-scheme (3FS) substation and a micro booster heat pump for domestic hot water. The novel design of the substation allows different operation modes between the grid and the building according to the temperature level and demand range every moment. Regarding the microbooster, this unit is used directly to lift the temperature of the domestic hot water (DHW), so that risk of legionella is avoided and that the required comfort temperature is reached. Preliminary test for the energy performance of the booster heat pump was measured on serially produced units according to tapping profiles and methodologies of standard EN16147. DHW coefficients of performance of 5.2 and 8.5 were measured for heat source supply temperatures respectively of 25 and 40 °C and return temperatures of 22 and 30 °C. This paper explores the possible operational modes of a 3FS in combination with a Building Integrated Solar Thermal System (BISTS) and a Microbooster heat pump.
- 1 September 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 609 (5) , 052008
Open AccessTriple function substation and high-efficiency micro booster heat pump for Ultra Low Temperature District Heating
District-Heating (DH) covers around the 9% of the total heat demand in the EU, with a proven highperformance levels and low operational costs. DH may suffer adaptations in order to maintain competitiveness with individual heating systems. The most important one is the reduction of supply temperatures up to 50°C, emerging the concept of Ultra Low Temperature (ULT) DH. ULT DH allows the transmission and distribution heat losses minimization, since heat losses are proportional to the temperature-gradient between supply line the ambient, increasing overall system performance. Furthermore, enables the integration of low-grade energy sources with low marginal costs, such as solar thermal energy or waste heat from industrial and commercial buildings. This study presents the combination of a novel 3 function-scheme (3FS) substation and a micro booster heat pump for domestic hot water. The novel design of the substation allows different operation modes between the grid and the building according to the temperature level and demand range every moment. Regarding the microbooster, this unit is used directly to lift the temperature of the domestic hot water (DHW), so that risk of legionella is avoided and that the required comfort temperature is reached. Preliminary test for the energy performance of the booster heat pump was measured on serially produced units according to tapping profiles and methodologies of standard EN16147. DHW coefficients of performance of 5.2 and 8.5 were measured for heat source supply temperatures respectively of 25 and 40 °C and return temperatures of 22 and 30 °C. This paper explores the possible operational modes of a 3FS in combination with a Building Integrated Solar Thermal System (BISTS) and a Microbooster heat pump.