Comparison of glottic visualisation and ease of intubation with different laryngoscope blades
Authors:
Open Access
- 1 March 2013
- journal article
- research article
- Published by Wolters Kluwer Health in Indian Journal of Anaesthesia
- Vol. 57 (2) , 170-174
Abstract
Context: Literature suggests glottic view is better with straight blades while tracheal intubation is easier with curved blades. Aims: To compare glottic view and ease of intubation with Macintosh, Miller, McCoy blades and the Trueview ® laryngoscope. Settings and Design: This prospective randomised study was undertaken in operation theatres of a 550 bedded tertiary referral cancer centre after approval from the Institutional Review Board. Methods: We compared the Macintosh, Miller, McCoy blades and the Trueview ® laryngoscope for glottic visualisation and ease of tracheal intubation; in 120 patients undergoing elective cancer surgery; randomly divided into four groups. After induction of anaesthesia laryngoscopy was performed and trachea intubated. We recorded: Visualisation of glottis (Cormack Lehane grade), ease of intubation, number of attempts; need to change the blade and need for external laryngeal manipulation. Statistical Analysis: Demographic data, Mallampati classification were compared using the Chi-square test. A P ® laryngoscope. Intubation was easier (Grade 1) with Trueview ® and McCoy blades (93% each). Seven patients needed two attempts; one patient in Miller group needed three attempts. No patient in McCoy and Trueview ® Groups required external laryngeal manipulation. Conclusions: We found that in patients with normal airway glottis was best visualised with Miller blade and Trueview ® laryngoscope however, the trachea was more easily intubated with McCoy and Macintosh blades and Trueview ® laryngoscope.Keywords
This publication has 17 references indexed in Scilit:
- Evaluation of new laryngoscope blade for tracheal intubation, Truview EVO2©;European Journal of Anaesthesiology, 2008
- Craniocervical Motion during Direct Laryngoscopy and Orotracheal Intubation with the Macintosh and Miller BladesAnesthesiology, 2007
- An evaluation of the TruView EVO2 laryngoscopeAnaesthesia, 2007
- A comparison of the Truview ® blade with the Macintosh blade in adult patientsAnaesthesia, 2007
- Laryngeal View During Laryngoscopy: A Randomized Trial Comparing Cricoid Pressure, Backward-Upward-Rightward Pressure, and Bimanual LaryngoscopyAnnals of Emergency Medicine, 2006
- A Clinical Comparison of the Flexiblade™ and Macintosh Laryngoscopes for Laryngeal Exposure in Anesthetized AdultsAnesthesia & Analgesia, 2006
- Quantitative improvement in laryngoscopic view by optimal external laryngeal manipulationJournal of Clinical Anesthesia, 1996
- Adverse Respiratory Events Infrequently Leading to Malpractice Suits A Closed Claims AnalysisAnesthesiology, 1991
- Difficult tracheal intubation: a retrospective studyAnaesthesia, 1987
- Improved vision modification of the Macintosh laryngosropeAnaesthesia, 1984