Polyethylene wear debris produced in a knee simulator model: Effect of crosslinking and counterface material
- 2 October 2009
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 92B (1) , 78-85
Abstract
Polyethylene (PE) debris has been well studied in clinical retrievals and laboratory wear simulations of total hip replacements. However, little is known about PE debris from total knee replacements. In this study, we investigated the effects of crosslinking PE bearings and alternate counterface material. Mildly (35 kGy) and highly (70 kGy) crosslinked PE were studied in combination with CoCr and zirconia femoral counterfaces. Wear debris was isolated and its morphology characterized. Except for changes in PE debris size with the zirconia bearings, there were no morphological changes greater than 10%. The average submicron volume fraction decreased from about 65% to 45% with both increased crosslinking and changing counterface material from CoCr to zirconia. The averaged number of generated particles decreased by ∼fourfold with increased crosslinking and threefold with changing counterface material from CoCr to zirconia. This showed that the degree of PE crosslinking and the choice of counterface material were important factors in the PE wear debris production in total knee simulator replacements. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2010Keywords
This publication has 45 references indexed in Scilit:
- Highly Crosslinked Polyethylene is Safe for Use in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2008
- “Severe” wear challenge to 36 mm mechanically enhanced highly crosslinked polyethylene hip linersJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2008
- Y‐TZP zirconia run against highly crosslinked UHMWPE tibial inserts: Knee simulator wear and phase‐transformation studiesJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2007
- Wear of sequentially enhanced 9‐Mrad polyethylene in 10 million cycle knee simulation studyJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2007
- Highly Crosslinked Polyethylenes in Hip Replacements: Improved Wear Performance or Paradox?Tribology Transactions, 2007
- Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulatorsJournal of Biomedical Materials Research Part A, 2006
- Letter to the editorJournal of Orthopaedic Research, 2001
- Shapes and dimensional characteristics of polyethylene wear particles generatedin vivo by total knee replacements compared to total hip replacementsJournal of Biomedical Materials Research, 1997
- Polyethylene wear debris and tissue reactions in knee as compared to hip replacement prosthesesJournal of Applied Biomaterials, 1994