Effect of Surgical Tightening Torque on the Pull-Out Strength of Screws in Vertebral Body Tethering
Open Access
- 16 October 2025
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 15 (20) , 11074
Abstract
Background/Objectives: Screw loosening and vertebral fractures remain common after vertebral body tethering (VBT). Because tightening torque sets screw preload, its biomechanical effect warrants explicit modeling. In this paper, a Finite Element (FE) model, supported by ex vivo porcine vertebral tests, was developed and validated that incorporates torque-induced pre-tension to quantify vertebral stress, aiming toward customizable VBT planning. Methods: An FE model with pre-tension and axial extraction failure was parameterized using ex vivo tests on five porcine vertebrae. A laterally inserted surgical screw in each specimen was tightened to Nm. Axial extraction produced failure loads of kN. This is also considered in the FE model to validate the failure scenario. Results: Torque alone generated peak von Mises stresses of MPa (cortical bone 1) and MPa (trabecular), lower than prior reports. With added axial load, peaks rose to MPa and MPa, exceeding typical ranges. However, predicted failure agreed with experiments, showing mm displacement and a conical displacement distribution around the washer. Conclusions: Modeling torque-induced pre-tension is essential to reproduce realistic stress states and anchor failure in VBT. The framework enables patient-specific assessment (bone geometry/density) to recommend safe tightening torques, potentially reducing screw loosening and early fractures.
Keywords
All Related Versions
This publication has 62 references indexed in Scilit:
- Surgical planning and finite element analysis for the neurocraneal protection in cranioplasty with PMMA: A case studyHeliyon, 2022
- Description and application of a comprehensive methodology for custom implant design and surgical planningInterdisciplinary Neurosurgery, 2022
- Computational modelling of the scoliotic spine: A literature reviewInternational Journal for Numerical Methods in Biomedical Engineering, 2021
- Stress analysis of the implants in transforaminal lumbar interbody fusion under static and vibration loadings: a comparison between pedicle screw fixation system with rigid and flexible rodsJournal of Materials Science: Materials in Medicine, 2019
- 3D correction over 2 years with anterior vertebral body growth modulation: A finite element analysis of screw positioning, cable tensioning and postoperative functional activitiesClinical Biomechanics, 2018
- Intra-operative measurement of applied forces during anterior scoliosis correctionClinical Biomechanics, 2016
- Segmental torso masses in adolescent idiopathic scoliosisClinical Biomechanics, 2014
- Biomechanical comparison of fusionless growth modulation corrective techniques in pediatric scoliosisMedical & Biological Engineering & Computing, 2011
- Simulation of an anterior spine instrumentation in adolescent idiopathic scoliosis using a flexible multi-body modelMedical & Biological Engineering & Computing, 2007
- Tightening characteristics for screwed joints in osseointegrated dental implantsThe Journal of Prosthetic Dentistry, 1994