Effect of Surgical Tightening Torque on the Pull-Out Strength of Screws in Vertebral Body Tethering
Preprint
- 5 September 2025
- preprint
- Published by MDPI AG in Preprints.org
Abstract
Background/Objectives: Screw loosening and vertebral fractures remain common after vertebral body tethering (VBT). Because tightening torque sets screw preload, its biomechanical effect warrants explicit modeling. In this paper, a Finite Element (FE) model, supported by ex-vivo porcine vertebrae tests, was developed and validated that incorporates torque-induced pre-tension to quantify vertebral stress, aiming toward customizable VBT planning. Methods: An FE model with pre-tension and axial extraction failure was parameterized using ex vivo tests on five porcine vertebrae. A laterally inserted surgical screw in each specimen was tightened to 5.9±0.80 [N·m]. Axial extraction produced failure loads of 2.1±0.31 [kN]. This is also considered in the FE model to validate the failure scenario. Results: Torque alone generated peak von Mises stresses of 16.1 [MPa] (cortical) and 2.1 [MPa] (trabecular), lower than prior reports. With added axial load, peaks rose to 141.1 [MPa] and 19.7 [MPa], exceeding typical ranges. However, predicted failure agreed with experiments, showing 0.58 [mm] displacement and a conical displacement distribution around the washer. Conclusions: Modeling torque-induced pre-tension is essential to reproduce realistic stress states and anchor failure in VBT. The framework enables patient-specific assessment (bone geometry/density) to recommend safe tightening torques, potentially reducing screw loosening and early fractures.Keywords
All Related Versions
- Version 1, 2025-09-05, Preprints
- Published version: Applied Sciences, 15 (20), 11074.
This publication has 39 references indexed in Scilit:
- Computational modelling of the scoliotic spine: A literature reviewInternational Journal for Numerical Methods in Biomedical Engineering, 2021
- Stress analysis of the implants in transforaminal lumbar interbody fusion under static and vibration loadings: a comparison between pedicle screw fixation system with rigid and flexible rodsJournal of Materials Science: Materials in Medicine, 2019
- Biomechanical properties of novel transpedicular transdiscal screw fixation with interbody arthrodesis technique in lumbar spine: A finite element studyJournal of Orthopaedic Translation, 2018
- 3D correction over 2 years with anterior vertebral body growth modulation: A finite element analysis of screw positioning, cable tensioning and postoperative functional activitiesClinical Biomechanics, 2018
- Intra-operative measurement of applied forces during anterior scoliosis correctionClinical Biomechanics, 2016
- The Effect of Time and Fusion Length on Motion of the Unfused Lumbar Segments in Adolescent Idiopathic ScoliosisSpine Deformity, 2015
- Segmental torso masses in adolescent idiopathic scoliosisClinical Biomechanics, 2014
- Biomechanical comparison of fusionless growth modulation corrective techniques in pediatric scoliosisMedical & Biological Engineering & Computing, 2011
- Simulation of an anterior spine instrumentation in adolescent idiopathic scoliosis using a flexible multi-body modelMedical & Biological Engineering & Computing, 2007
- Tightening characteristics for screwed joints in osseointegrated dental implantsThe Journal of Prosthetic Dentistry, 1994