A Parametric Study of an Indirect Evaporative Cooler Using a Spray Dryer Model
Open Access
Abstract
Indirect evaporative coolers (IECs) are becoming a viable alternative to the more energy-intensive traditional HVAC systems for space cooling, especially in arid regions. In this work, a recently developed computational model of an IEC was used to conduct a parametric study. The model employs a spray dryer model to track the flow path and evaporation rate of droplets. The key parameters investigated were the temperature of the droplets, a bypass effect where the amount of exhaust air and water was reduced to as low as 10%, and the length of the heat exchanger. The results suggest that the wet bulb efficiency could be increased from the previously observed 35% to 72.5% if the water temperature is decreased to 16 °C. In order to drastically increase the performance, the heat exchanger length should be increased from 50 cm to 100 cm, which could still end up in a more compact design overall as fewer plates are required. The bypass study resulted in peak performance when 40% of the secondary air flow was used as working air in conjunction with a proportional reduction in water usage. Overall, the computational model has been employed in an attempt to reduce the bulkiness, increase the efficiency and reduce the water consumption of such a system.Keywords
This publication has 32 references indexed in Scilit:
- Performance evaluation of counter flow dew-point evaporative cooler with a three-dimensional numerical modelApplied Thermal Engineering, 2022
- On the fundamental heat and mass transfer analysis of the counter-flow dew point evaporative coolerApplied Energy, 2018
- Indirect Evaporative cooling systems: modelling and performance analysisEnergy Procedia, 2017
- Experimental investigation of a super performance dew point air coolerApplied Energy, 2017
- Modeling and experimental study of an indirect evaporative coolerEnergy and Buildings, 2017
- Numerical simulation of a novel energy-efficient dew-point evaporative air coolerApplied Energy, 2014
- Numerical study of a novel dew point evaporative cooling systemEnergy and Buildings, 2010
- Numerical study of a novel counter-flow heat and mass exchanger for dew point evaporative coolingApplied Thermal Engineering, 2008
- A review on buildings energy consumption informationEnergy and Buildings, 2008
- What is important in the simulation of spray dryer performance and how do current CFD models perform?Applied Mathematical Modelling, 2006