Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Torsten Berning has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Computational Fluid Dynamics Analysis of a Proton Exchange Membrane Fuel Cell with a Perforated Metal Gas Diffusion Layer

    by Torsten Berning, Volodymyr Korobko, Shiro Tanaka

    This work summarizes the computational modeling of multi-phase flow, heat and mass transfer in a proton exchange membrane fuel cell with a perforated metal plate replacing the cathode carbon fiber paper (CFP) as gas diffusion layer (GDL). Such a metal GDL has a higher thermal conductivity than standard CFPs and allows for high current density operation. The 100-micron holes are discretized and, therefore, only a 600 micron long channel section is investigated. This section is placed at the cathode inlet, and the effect of local current density is investigated for a high flow rate. The calculated membrane hydration level ranges from λ = 7 at a current density of 1.0 A cm−2 to a fully hydrated membrane with λ = 14 at 4.0 A cm−2. Owing to the high inlet pressure, the limiting current density is around 5.0 A cm−2. This is lower than intended, and the reason is a flooding effect. The elevated inlet pressure requires a compressor which leads to a strong temperature increase and drying out of the incoming air stream. It is suggested to apply a spray nozzle instead of a membrane humidifier to humidify and also cool down the air stream behind the compressor.

  • Open Access

    A Computational Fluid Dynamics Analysis of Multiphase Flow in the Anode Side of a Proton Exchange Membrane Electrolyzer

    by Torsten Berning, Thomas Condra

    This work describes an innovative three-dimensional model of a proton exchange membrane electrolyzer. For the first time, a multi-phase model has captured segregated channel flow together with multiphase flow in a porous medium, as well as heat transfer and phase change employing an Eulerian multiphase model. The novel electrolyzer design investigated employs a symmetrical, interdigitated flow field to facilitate even water distribution. In the current case, a hot spot is predicted with a temperature increase of 7 °C at a current density of 1.0 A/cm2. The flow field plates are horizontally oriented, and it is shown that gravity plays an important role in the electrolyzer design and orientation. A parametric study shows, for the first time, the effect of operating a PEM electrolyzer at sub-ambient anode pressure to favorably adjust the concentration ratio between water vapor and oxygen in the anode compartment. This ratio is increased by a factor of 5.6 when the pressure is decreased from one bar to 500 mbar.

  • Open Access

    A Computational Fluid Dynamics Analysis of Multiphase Flow in the Anode Side of a Proton Exchange Membrane Electrolyzer

    by Torsten Berning, Thomas Condra

    A computational fluid dynamics analysis of the anode side of a proton exchange membrane (PEM) electrolyzer cell has been conducted. The geometry is symmetrical and allows for the investigation of a single feed channel and a single exhaust channel in an interdigitated flow field. The model utilizes the Eulerian approach and thus solves a full set of conservation equations for both gas and liquid phase. Moreover, it is non-isothermal and it includes phase change of water. The operating stoichiometric flow ratio results in segregated flow in the horizontal flow channels. At a current density of 1.0 A/cm2, a local hot spot with a temperature increase of 7 °C is predicted. A reduction in the operating pressure below atmospheric pressure results in a more favorable concentration ratio of water vapor to oxygen at the PTL/CL interface, and the temperature distribution is more even. However, when the outlet pressure is too low, the outlet temperature is below the inlet temperature which makes this operation mode unfeasible. Adjustment of the back pressure can generally be used to control the temperature of the electrolyzer.

  • Open Access

    A Parametric Study of an Indirect Evaporative Cooler Using a Spray Dryer Model

    by Torsten Berning, Tianbao Gu, Chungen Yin

    Indirect evaporative coolers (IECs) are becoming a viable alternative to the more energy-intensive traditional HVAC systems for space cooling, especially in arid regions. In this work, a recently developed computational model of an IEC was used to conduct a parametric study. The model employs a spray dryer model to track the flow path and evaporation rate of droplets. The key parameters investigated were the temperature of the droplets, a bypass effect where the amount of exhaust air and water was reduced to as low as 10%, and the length of the heat exchanger. The results suggest that the wet bulb efficiency could be increased from the previously observed 35% to 72.5% if the water temperature is decreased to 16 °C. In order to drastically increase the performance, the heat exchanger length should be increased from 50 cm to 100 cm, which could still end up in a more compact design overall as fewer plates are required. The bypass study resulted in peak performance when 40% of the secondary air flow was used as working air in conjunction with a proportional reduction in water usage. Overall, the computational model has been employed in an attempt to reduce the bulkiness, increase the efficiency and reduce the water consumption of such a system.


  • Open Access

    A Conceptual Approach to Reduce the Product Gas Crossover in Alkaline Electrolyzers

    by Diogo Loureiro Martinho, Torsten Berning

    The crossover of the product gases hydrogen and oxygen in alkaline electrolyzer operation is a critical factor, severely limiting the operational window in terms of current density and pressure. In prior experiments, it was found that a large degree of oversaturation of the reaction products in the liquid electrolyte phase leads to high amounts of crossover. We are proposing to reduce this amount of oversaturation by introducing micro-cracks in the Zirfon diaphragm. These cracks are meant to induce the formation of hydrogen and oxygen bubbles on the respective sides, and thereby reduce the oversaturation and amount of crossover. In theory, the size of the bubble corresponds to the size of the cracks, and from our computational fluid dynamics simulations, we conclude that the bubbles should be as large as possible to minimize the ohmic resistance in the electrolyte phase. The results suggest that an increase in bubble diameter from 50 microns to 150 microns results in a 10% higher current density at a cell voltage of 2.1 V.


  • Open Access

    Design of a Proton Exchange Membrane Electrolyzer

    by Torsten Berning

    A novel design of a proton exchange membrane electrolyzer is presented. In contrast to previous designs, the flow field plates are round and oriented horizontally with the feed water entering from a central hole and spreading evenly outward over the anode flow field in radial, interdigitated flow channels. The cathode flow field consists of a spiral channel with an outlet hole near the outside of the bipolar plate. This results in anode and cathode flow channels that run perpendicular to avoid shear stresses. The novel sealing concept requires only o-rings, which press against the electrolyte membrane and are countered by circular gaskets that are placed over the flow channels to prevent the membrane from penetrating the channels, which makes for a much more economical sealing concept compared to prior designs using custom-made gaskets. Hydrogen leaves the electrolyzer through a vertical outward pipe placed off-center on top of the electrolyzer. The electrolyzer stack is housed in a cylinder to capture the oxygen and water vapor, which is then guided into a heat exchanger section, located underneath the electrolyzer partition. The function of the heat exchanger is to preheat the incoming fresh water and condense the escape water, thus improving the efficiency. It also serves as internal phase separator in that a level sensor controls the water level and triggers a recirculation pump for the condensate, while the oxygen outlet is located above the water level and can be connected to a vacuum pump to allow for electrolyzer operation at sub-ambient pressure to further increase efficiency and/or reduce the iridium loading.


  • Open Access

    A One-Dimensional Computational Model to Identify Operating Conditions and Cathode Flow Channel Dimensions for a Proton Exchange Membrane Fuel Cell

    by Nikolaj Maack Bielefeld, Rasmus Dockweiler Sørensen, Mikkel Jørgensen, Kristoffer Kure, Torsten Berning

    A one-dimensional computational model has been developed that can be used to identify operating conditions for the cathode side of a proton exchange membrane fuel cell such that both the inlet and outlet relative humidity is equal to 100%. By balancing the calculated pressure drop along the cathode side flow channel with the change in molar composition, inlet conditions for the cathode side can be identified with the goal of avoiding channel flooding. The channel length, height, width and the land-to-channel width ratio are input parameters for the model so that it might be used to dimension the cathode flow field. The model can be used to calculate the limiting current density, and we are presenting unprecedented high values as a result of the high pressure drop along the flow channels. Such high current densities can ultimately result in a fuel cell power density beyond the typical value of 1.0–2.0 W/cm2 for automotive fuel cells.


  • Open Access

    High Current Density Operation of a Proton Exchange Membrane Fuel Cell with Varying Inlet Relative Humidity—A Modeling Study

    by Wei Liu, Anders Christian Olesen, Vincenzo Liso, Torsten Berning

    This paper focuses on proton exchange membrane fuel cell (PEMFC) operation at current densities in the order of 6 A/cm2. Such high current densities are conceivable when the traditional carbon fiber papers are replaced with perforated metal plates as the gas diffusion layer to enhance waste heat removal, and at the same time the relative humidity inside the fuel cell is kept below 100% by applying appropriate operating conditions as was found in previous one-dimensional modeling work. In the current paper, we applied a three-dimensional, multi-phase computational fluid dynamics model based on Ansys-CFX to obtain additional insight into the underlying physics. The calculated pressure drops are in very good agreement with previous one-dimensional modeling work, and the current densities in all case studies are in the order of 5–6 A/cm2, but different from the previous one-dimensional study, the results suggest that the relative humidity is very close to 100% throughout the entire channel length when the inlet relative humidity is 100%, ensuring best hydration cell conditions and hence best performance. Importantly, the model results suggest that fuel cell performance at a high current density in conjunction with relatively low stoichiometric flow ratios around 1.5–2 is possible.