A Novel Electrochemical Testing Method and Its Use in the Investigation of Underfilm Corrosion of Temporarily Protective Oil Coating
Author:
- 1 July 2000
- journal article
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 56 (7) , 722-726
Abstract
A novel electrochemical method was developed to investigate underfilm corrosion of a temporarily protective oil coating. A multiple wire electrode was used to allow electrochemical parameters and their distributions to be measured directly from the coating/metal interface. This made it possible to measure electrochemical parameters that were related to underfilm corrosion directly so as to study the mechanism of underfilm corrosion. Corrosion currents of microcorrosion cells were measured. Anodic and cathodic areas of an underfilm corrosion cell also were documented. Results showed that underfilm corrosion taking place at the coating/metal interface was heterogeneous. It was suggested that this method is helpful in investigating the mechanism of underfilm corrosion and in studying the degradation process of oil coatings.Keywords
This publication has 8 references indexed in Scilit:
- Wire-beam electrode: a new tool for investigating electrochemical inhomogeneity of oil coatingsProgress in Organic Coatings, 1997
- Terpene-anhydride resin based coatings IIProgress in Organic Coatings, 1997
- Distribution of Steady-State Cathodic Currents Underneath a Disbonded CoatingCorrosion, 1994
- Current and Potential Distribution on a Coated Pipeline with Holidays Part I—Model and Experimental VerificationCorrosion, 1993
- A critical review of d.c. electrochemical tests for painted metalsCorrosion Science, 1986
- Simulated Underfilm Corrosion of Coated Mild Steel Using an Artificial BlisterCorrosion, 1983
- Corrosion at a Holiday in an Organic Coated-Metal Substrate SystemCorrosion, 1976
- The protective action of paint filmsSurface Technology, 1976