Novel contouring method for optimizing MRI flow quantification in patients with aortic valve disease
Open Access
- 30 January 2024
- journal article
- research article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 40 (3) , 665-673
Abstract
Optimizing MRI aortic flow quantification is crucial for accurate assessment of valvular disease severity. In this study, we sought to evaluate the accuracy of a novel method of contouring systolic aortic forward flow in comparison to standard contouring methods at various aortic levels. The study included a cohort of patients with native aortic valve (AoV) disease and a small control group referred to cardiac MRI over a 1-year period. Inclusion criteria included aortic flow quantification at aortic valve and one additional level, and no or trace mitral regurgitation (MR) documented both by the MRI AND an echocardiogram done within a year. In addition to flow quantification with standard contouring (SC), a novel Selective Systolic Contouring (SSC) method was performed at aortic valve level, contouring the area demarcated by the AoV leaflets in systole. The bias in each technique’s estimate of aortic forward flow was calculated as the mean difference between aortic forward flow and left ventricular stroke volume (LV SV). 98 patients (mean age 56, 71% male) were included: 33 with tricuspid and 65 with congenitally abnormal (bicuspid or unicuspid) AoV. All methods tended to underestimate aortic forward flow, but the bias was smallest with the SSC method (p < 0.001). Therefore, SSC yielded the lowest estimates of mitral regurgitant volume (4.8 ml) and regurgitant fraction (3.9%) (p < 0.05). SSC at AoV level better approximates LV SV in our cohort, and may provide more accurate quantitative assessment of both aortic and mitral valve function.Keywords
This publication has 15 references indexed in Scilit:
- Flow vortices in the aortic root: in vivo 4D-MRI confirms predictions of Leonardo da VinciEuropean Heart Journal, 2014
- Quantification of aortic flow by phase-contrast magnetic resonance in patients with bicuspid aortic valveEuropean Heart Journal - Cardiovascular Imaging, 2013
- Effect of protocol choice on phase contrast cardiac magnetic resonance flow measurement in the ascending aorta: breath-hold and non-breath-holdThe International Journal of Cardiovascular Imaging, 2012
- Comparison of Severity of Aortic Regurgitation by Cardiovascular Magnetic Resonance Versus Transthoracic EchocardiographyThe American Journal of Cardiology, 2011
- Bicuspid Aortic Valve: Four-dimensional MR Evaluation of Ascending Aortic Systolic Flow PatternsRadiology, 2010
- Baseline Correction of Phase Contrast Images Improves Quantification of Blood Flow in the Great VesselsJournal of Cardiovascular Magnetic Resonance, 2007
- Flow patterns in the aortic root and the aorta studied with time-resolved, 3-dimensional, phase-contrast magnetic resonance imaging: implications for aortic valve–sparing surgeryThe Journal of Thoracic and Cardiovascular Surgery, 2004
- Cardiovascular Flow Measurement with Phase-Contrast MR Imaging: Basic Facts and ImplementationRadioGraphics, 2002
- Leonardo da Vinci and the sinuses of ValsalvaThe Annals of Thoracic Surgery, 1991
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986