Abstract
Due to the potential for high power density and high efficiency, the isolated AC-DC matrix converter is an attractive alternative for voltage source converters in applications requiring isolation and bidirectional power flow. However, existing control schemes fail to coordinate the modulation index and phase shift angle, and instead focus on optimizing one of the two variables. This can cause high current stress on the high frequency transformer, leading to low efficiency under a light load. To optimize the operation of the isolated AC-DC matrix converter, the coordination control of the modulation index and phase shift angle is proposed in this paper to suppress the peak current of the transformer. Firstly, a mathematical model based on Fourier transform is established to calculate the current stress. Then, the optimal combination of the modulation index and the phase shift angle is obtained to minimize the current stress and improve the converter efficiency. Simulation and experimental results on an isolated AC-DC matrix converter are provided to verify the effectiveness of the proposed method.
Funding Information
  • Natural Sciences and Engineering Research Council of Canada
  • University of Alberta
  • Canada First Research Excellence Fund

This publication has 33 references indexed in Scilit: