Telecentric model eye for correction of image distortion in adaptive optics ophthalmoscopes
- 16 June 2025
- journal article
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (7) , 2767-2791
Abstract
Here, we demonstrate a telecentric model eye for measuring scanning, sampling, and optical distortion in AO ophthalmoscopes across a 10-diopter focus range, seeking to improve the reproducibility of adaptive optics (AO) ophthalmoscopy biomarkers. The model eye lens provides diffraction-limited performance when imaging with 800 nm light over circular 2.0, 3.0, 4.6, and 9.2° fields of view through 8, 6, 4, and 2 mm diameter aperture stops, respectively. Measurements of double-pass wavefront aberrations using both model and real retinas show that the use of opal glass model retinas, rough model retina surfaces, and wavefront sensing beacon scanning mitigate first-pass aberrations. This is particularly important, as first-pass aberrations are often assumed but not always achieved in AO ophthalmoscopes. Using the model eye with custom distortion estimation algorithms, we recorded 0.06% non-isotropic scaling repeatability, 0.02° shear repeatability, 0.5% reproducibility for both metrics and a root-mean-square residual distortion of 0.1 pixels across the field of view and focus range.Keywords
Funding Information
- National Eye Institute (R01EY032147, R01EY032669, R01EY031360, P30EY026877, OT2OD038128)
- Research to Prevent Blindness (Departmental Award)
This publication has 59 references indexed in Scilit:
- Large-field-of-view, modular, stabilized, adaptive-optics-based scanning laser ophthalmoscopeJournal of the Optical Society of America A, 2007
- Distortion and Size Calibration of the Scanning Laser Ophthalmoscope (SLO) Laser-Beam RasterOptometry and Vision Science, 2003
- Standards for Reporting the Optical Aberrations of EyesJournal of Refractive Surgery, 2002
- Dynamics of the eye’s wave aberrationJournal of the Optical Society of America A, 2001
- Adaptive Optics OphthalmoscopyJournal of Refractive Surgery, 2000
- Laser Ray Tracing versus Hartmann–Shack sensor for measuring optical aberrations in the human eyeJournal of the Optical Society of America A, 2000
- Single-pass measurements of the wave-front aberrations of the human eye by use of retinal lipofuscin autofluorescenceOptics Letters, 1999
- Double-pass measurements of the retinal-image quality with unequal entrance and exit pupil sizes and the reversibility of the eye’s optical systemJournal of the Optical Society of America A, 1995
- Odd aberrations and double-pass measurements of retinal image qualityJournal of the Optical Society of America A, 1995
- Objective measurement of wave aberrations of the human eye with the use of a Hartmann–Shack wave-front sensorJournal of the Optical Society of America A, 1994