KKKarteek Kunala

Karteek Kunala

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Karteek Kunala has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Glass wedge strabismic imaging for scanning instruments

    by Gastón A. Ayubi, Karteek Kunala, Yuning Xia, Alfredo Dubra

    We propose using a custom glass wedge in reflection to generate two illumination beams for implementing strabismic imaging in point- and line-scanning imaging instruments. We present wedge design formulae that ensure beam overlap at pupil conjugates while achieving a desired beam separation at image conjugates. These formulae provide, for an in-plane wedge rotation, the rotation angle of the primary reflection from the second wedge surface about the primary reflection from the first surface, and the resulting small residual separation at pupil conjugates. We demonstrate the approach in an adaptive optics scanning light ophthalmoscope with reflectance confocal and non-confocal imaging channels. This low-cost, low-complexity method for generating strabismic illumination from a single collimated beam provides long-term mechanical stability and is broadly applicable across imaging modalities.

  • Automated montaging and contrast stretching of adaptive optics ophthalmoscope images

    by Gastón A. Ayubi, Karteek Kunala, Alfredo Dubra

    We present an automated montaging method for distortion-corrected single- and multi-channel adaptive optics ophthalmoscope images. The approach employs a zero-mean normalized weighted cross-correlation (ZNWCC) that enables assigning real-valued pixel weights to account for irregular image boundaries, spatially varying signal-to-noise ratio, and motion of retinal features. An initial sub-pixel pairwise registration using translation, rotation, and, if needed, scaling is refined with a global registration quality metric derived from peak ZNWCC values. The images are montaged through weighted averaging and contrast stretching that equalize mean image brightness and contrast in overlapping regions, compensating for differences in overall illumination, detector offset, and detector gain. A final montage is created by combining the transformed images calculated through a single interpolation to mitigate loss of resolution, and with an optional polynomial field-flattening step to increase contrast throughout the montage. The method is demonstrated on AO retinal image sets from human and mouse eyes.


  • Open Access

    Strabismic imaging for correcting in-plane motion distortion in scanning imaging instruments and rolling shutter cameras

    by Gastón A. Ayubi, Karteek Kunala, Bartlomiej Kowalski, Aubrey Hargrave, Alfredo Dubra

    Images acquired with point-scanning instruments, line-scanning instruments, and rolling shutter cameras are distorted by motion of the instrument or the scene. This distortion arises from the sequential capture of pixels or rows of pixels and is known as the rolling shutter effect. Here, we demonstrate the correction of rolling shutter distortion caused by in-plane motion with a dual-imaging technique inspired by strabismus, an eye misalignment condition. When the velocity observed in pairs of synchronously captured and misaligned images can be considered constant within each image row or column, the distortion estimation problem can be formulated as a system of linear equations describing the displacement of image strips along the slow scanning direction or as an optimization problem that maximizes the similarity between the two distortion-corrected images. Both methods can be modified to correct motion distortion caused by in-plane rotation and scaling changes. Strabismic image pairs, acquired with a point-scanning instrument and a dual-rolling shutter camera setup, are used to demonstrate both approaches.


  • Refractive adaptive optics scanning light ophthalmoscope with fast 2D MEMS scanner

    by Karteek Kunala, Yuning Xia, Gastón A. Ayubi, Bartlomiej Kowalski, Ankur X. Desai, David Lippman, Julie Bentley, Alfredo Dubra

    We describe a refractive adaptive optics scanning light ophthalmoscope designed for small animal imaging through a 1.8 mm diameter pupil. The optical setup, based on a search of achromatic doublets through multiple lens catalogs, consists of a sequence of modified afocal relays that deliver diffraction-limited imaging in pupil and retina conjugates. Real ray tracing is used to compare imaging performance when correcting large focus errors using a pupil conjugate wavefront corrector, a traditional Badal optometer, and a modified Badal optometer. Polarization control, focal length selection, and systematic lens tilting are explored for mitigating reflections with minimal imaging performance degradation. A 2-dimensional optical scanner with a 29.2 kHz resonant frequency around one axis and low dynamic surface distortion allows doubling the frame rate of prior instruments and simplifies the optical setup. Scanner orientation and trigger electrical signals are used to correct sinusoidal image warping and line sampling jitter. The instrument is demonstrated by imaging mice under 800 nm illumination with two reflectance detection modalities: confocal and quadrant non-confocal.


  • Automated animal gimbal steering for retinal imaging and stimulation

    by Karteek Kunala, Gastón A. Ayubi, Joel A. Franco, Vinit B. Mahajan, Alfredo Dubra

    Here, we propose optomechanical devices for steering anesthetized animals during retinal imaging and/or stimulation with stationary ophthalmoscopes. Simple operating procedures ensure that the entrance pupil of the eye remains centered on the exit pupil of the ophthalmoscope during steering, to avoid vignetting. The devices, built with commercially available manual linear stages and motorized rotating devices, can be used to capture image sequences for tiling, as is often done in microscopy. This automated steering system, demonstrated here in mice, is applicable to other animal species and imaging modalities, as well as explanted eyes. The use of these devices can reduce imaging time and retinal light exposure, both of which are important when using ophthalmoscopes with small fields of view, such as adaptive optics ophthalmoscopes, while also improving animal welfare.


  • Low-cost non-contact axial placement and active focusing of optical components

    by Karteek Kunala, Alfredo Dubra

    A low-cost non-contact method for placement of optical elements with or without optical power, as well as opto-mechanical elements along an optical axis, is demonstrated. This approach utilizes a camera mounted on a linear stage to capture images of surface imperfections illuminated by oblique incoherent light. Two variations of the method allow placing elements at nominal distances, while a third variation allows active focusing to account for radius errors in elements with power.


  • Telecentric model eye for correction of image distortion in adaptive optics ophthalmoscopes

    by Vyas Akondi, Gastón A. Ayubi, Xiaojing Huang, Karteek Kunala, Alfredo Dubra

    Here, we demonstrate a telecentric model eye for measuring scanning, sampling, and optical distortion in AO ophthalmoscopes across a 10-diopter focus range, seeking to improve the reproducibility of adaptive optics (AO) ophthalmoscopy biomarkers. The model eye lens provides diffraction-limited performance when imaging with 800 nm light over circular 2.0, 3.0, 4.6, and 9.2° fields of view through 8, 6, 4, and 2 mm diameter aperture stops, respectively. Measurements of double-pass wavefront aberrations using both model and real retinas show that the use of opal glass model retinas, rough model retina surfaces, and wavefront sensing beacon scanning mitigate first-pass aberrations. This is particularly important, as first-pass aberrations are often assumed but not always achieved in AO ophthalmoscopes. Using the model eye with custom distortion estimation algorithms, we recorded 0.06% non-isotropic scaling repeatability, 0.02° shear repeatability, 0.5% reproducibility for both metrics and a root-mean-square residual distortion of 0.1 pixels across the field of view and focus range.


  • Open Access

    Optogenetic therapy restores retinal activity in primate for at least a year following photoreceptor ablation

    by Juliette E. McGregor, Karteek Kunala, Zhengyang Xu, Peter J. Murphy, Tyler Godat, Jennifer M. Strazzeri, Brittany A. Bateman, William S. Fischer, Keith Parkins, Colin J. Chu, et al.


  • Random anti-reflection subwavelength surface structures on deterministic illumination diffusers

    by Praneeth Gadamsetti, Karteek Kunala, Menelaos K. Poutous

    Deterministic illumination diffractive-diffusers have non-periodic short and medium scale topography. Because of the quasi-randomized locations and vertical sidewalls at phase transition boundaries, over-coating diffractive diffusers with thin film antireflection layers perturbs their function, resulting in illumination performance deviations and nonuniformities. To mitigate these effects, we added anti-reflection random nano-structures (rARSS) on the surface of three different classes of fused-silica multi-phase diffractive diffusers, using reactive-ion plasma etching. The diffusers were measured before and after the random nanostructure addition, using a polarized-laser scatterometer with a dynamic range of nine orders-of-magnitude. The bi-directional scatter distribution function (BSDF) was measured over the entire equatorial plane of incidence, to analyze the directionality of scattered light, and the impact of the rARSS on the optical performance of the diffusers. An overall Fresnel reflectivity suppression was measured in the directional illumination patterns, as well as, across the entire 180° angle-sweep. The designed deterministic illumination distribution patterns and contrast were unaffected by the presence of the rARSS.

  • Optical Scattering of Deterministic Diffractive Elements with Antireflective Structured Surfaces

    by Praneeth Gadamsetti, Karteek Kunala, Menelaos K. Poutous

    Diffractive optical elements with complicated multi-layered phase profiles, require the suppression of Fresnel reflections in cascading-component optical systems. Random nanostructures have been shown to reduce Fresnel reflectivity of optical windows, lenses, and linear gratings. To-date, no reports of such antireflective treatments have been reported on deterministic diffractive optics. Random subwavelength structures were implemented on the diffractive phase profiles of a deterministic illumination diffuser. The diffuser was tested before and after the nanostructure addition, and significant reduction of the reflected scatter was measured with a moderate transmission enhancement. The results also show no adverse effects on the target irradiance distribution of the diffractive element.